LMLC1-1RLS4-24314-3-V Circuit Protection |
|
Allicdata Part #: | LMLC1-1RLS4-24314-3-V-ND |
Manufacturer Part#: |
LMLC1-1RLS4-24314-3-V |
Price: | $ 57.88 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIR BRKR MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | LMLC1-1RLS4-24314-3-V Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
6 +: | $ 52.61550 |
Series: | LML |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 1 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
LMLC1-1RLS4-24314-3-V Application Field and Working Principle
Circuit breakers are essential components in a variety of electrical circuits, with the function of preventing overcurrent and overvoltage in the circuit, and providing protection against electric shock, both for personnel and for equipment used in the circuit. The sensor device is one of the most important part of the circuit breaker, the function of which is to analyze the electrical parameters in real time, to trigger the trip device in time when the detection value breaches the set threshold value and open the circuit when an overload, short circuit or other fault occurs.
LMLC1-1RLS4-24314-3-V Application Field
The LMLC1-1RLS4-24314-3-V has many applications that require a circuit breaker to provide the best protection and reliability. Typical applications include: home appliances, LED lighting systems, simple automation applications, motor control panels, UPS systems, circuit power protection, industrial power supply systems, automotive, marine, military and aerospace industries.
Advanced quality systems and innovative technologies are used in all these application fields to ensure the highest quality and dependability of the LMLC1-1RLS4-24314-3-V circuit breaker.
LMLC1-1RLS4-24314-3-V Working Principle
The LMLC1-1RLS4-24314-3-V works on a principle based on the relationship between the current passing through the device, the voltage drop across it and the contact time. It is a device that can quickly detect an overload or short circuit current and immediately open the circuit to protect both the equipment and personnel.
The sensor of a circuit breaker continuously monitors the current passing through and the voltage of the system, by measuring the magnitude and frequency of the current passing through. Sensitivity determines the instantaneous trip characteristics, which can effectively detect and trip any form of over-current in the circuit. The sensor also detects any sustained overload current along with a ground fault current and other fault conditions, which is then instantaneously acted upon by the trip device, thus immediately opening the circuit.
The room temperature and humidity of the environment also affect the operation of the circuit breaker. The operating temperature range of the device should be considered, and measures should be taken to protect the device against condensation, dust and other foreign materials as well as corrosion which could affect its behavior.
Conclusion
The LMLC1-1RLS4-24314-3-V is a highly reliable and versatile circuit breaker that is suitable for use in a variety of applications such as home appliances, LED lighting systems, simple automation applications, motor control panels, UPS systems, circuit power protection, industrial power supply systems, automotive, marine, military and aerospace industries. Highly advanced and innovative technologies are used in its construction, enabling it to provide efficient and reliable protection against overcurrent and other fault conditions. It works on a principle based on the relationship between the current passing through the device, the voltage drop across it and the contact time. It can quickly detect an overload or short circuit current and immediately open the circuit to protect both the equipment and personnel.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
LMLC1-1RLS4-24314-49-V | Sensata-Airp... | 49.13 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1REC4-24314-59-V | Sensata-Airp... | 67.19 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-34991-80 | Sensata-Airp... | 67.19 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-51-40.0-01-V | Sensata-Airp... | 76.01 $ | 1000 | CIR BRKR MAG-HYDR 40A LEV... |
LMLC1-1RLS4-52-40.0-01 | Sensata-Airp... | 76.01 $ | 1000 | CIR BRKR MAG-HYDR 40A LEV... |
LMLC1-1RLS4-33831-100 | Sensata-Airp... | 93.72 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-51-80.0-01 | Sensata-Airp... | 93.78 $ | 1000 | CIR BRKR MAG-HYDR 80A LEV... |
LMLC1-1RLS4-52-60.0-01 | Sensata-Airp... | 93.78 $ | 1000 | CIR BRKR MAG-HYDR 60A LEV... |
LMLC1-1RLS4-51-100.-01-V | Sensata-Airp... | 93.78 $ | 1000 | CIR BRKR MAG-HYDR |
LMLC1-1RLS4-51-100.-41-V | Sensata-Airp... | 93.78 $ | 1000 | CIR BRKR MAG-HYDR |
LMLC1-1RLS4-51-60.0-01-V | Sensata-Airp... | 93.78 $ | 1000 | CIR BRKR MAG-HYDR |
LMLC1-1REC4-24314-58-V | Sensata-Airp... | 95.07 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28448-11 | Sensata-Airp... | 95.07 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-33212-1 | Sensata-Airp... | 95.07 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-34992-80-V | Sensata-Airp... | 95.07 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-42-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-43-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-44-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-45-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-46-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-60-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-7-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-8-V | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28448-13 | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-30414-100 | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-30414-60 | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-30414-70 | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-30414-80 | Sensata-Airp... | 102.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-40-V | Sensata-Airp... | 58.44 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-24314-41-V | Sensata-Airp... | 58.44 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-34655-20-V | Sensata-Airp... | 58.44 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-34087-34-V | Sensata-Airp... | 59.09 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-34087-3-V | Sensata-Airp... | 59.09 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-34087-48-V | Sensata-Airp... | 59.09 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28524-10 | Sensata-Airp... | 59.8 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28524-15 | Sensata-Airp... | 59.8 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28524-20 | Sensata-Airp... | 59.8 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28524-25 | Sensata-Airp... | 59.8 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28524-3 | Sensata-Airp... | 59.8 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
LMLC1-1RLS4-28524-30 | Sensata-Airp... | 59.8 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A