Allicdata Part #: | 570-1377-ND |
Manufacturer Part#: |
MS32 20010-B |
Price: | $ 3.24 |
Product Category: | Circuit Protection |
Manufacturer: | Ametherm |
Short Description: | ICL 20 OHM 25% 10A 31MM |
More Detail: | Inrush Current Limiter 20 Ohms ±25% 10A 1.220" (31... |
DataSheet: | MS32 20010-B Datasheet/PDF |
Quantity: | 1229 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 2.94210 |
5 +: | $ 2.84004 |
10 +: | $ 2.73861 |
50 +: | $ 2.13003 |
100 +: | $ 1.77502 |
250 +: | $ 1.72431 |
500 +: | $ 1.47073 |
1000 +: | $ 1.39466 |
Series: | MegaSurge™ |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
R @ 25°C: | 20 Ohms |
Tolerance: | ±25% |
Current - Steady State Max: | 10A |
R @ Current: | 180 mOhms |
Diameter: | 1.220" (31mm) |
Lead Spacing: | 0.307" (7.80mm) |
Approvals: | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Inrush current limiters (ICLs) are essential components in numerous electrical applications, such as high-performance power systems and air conditioning systems. In particular, MS32 20010-B is a type of ICL that is used in a wide range of applications due to its efficient performance and reliability. This device enables inrush current protection for a large variety of electrical systems. In this article, we will discuss the application field and working principle of the MS32 20010-B inrush current limiter.
The MS32 20010-B inrush current limiter is an essential component in several domestic and commercial applications. For instance, this device is commonly used in automotive and aerospace applications, such as fuel pumps, lights, and ignition coils. Additionally, it is particularly effective in addressing high-voltage scenarios since it can provide current limiting capabilities up to 45A. This should be taken into account during the design of the application due to the fact that the rated current should be suitable for the specific needs of the project. Apart from automotive and aerospace systems, this ICL is suitable for industrial applications and machines, such as welding equipment, robots, and air conditioning systems. In each of these applications, the MS32 20010-B inrush current limiter is key to providing surge protection and guaranteeing the safety of the system.
Moreover, this inrush current limiter is also compatible with control systems due to its high level of protection. From a control perspective, the MS32 20010-B provides a high degree of versatility, due to its excellent noise immunity and robust surge protection capabilities. In addition, it is extremely compact, making it easy to incorporate into existing control systems with minimal disruption. Furthermore, the device can be easily adapted to new systems due to its high level of flexibility and scalability. All of these features make the MS32 20010-B inrush current limiter an ideal choice for many control systems.
In addition, the MS32 20010-B inrush current limiter is designed to trip immediately to prevent the damage of electrical components in case of a surge. This is achieved through a set of internal components, including an electronic clamp and an overflow circuit. The electronic clamp limits the initial inrush current, while the overflow circuit prevents subsequent inrush currents. Furthermore, the device is equipped with advanced protection features such as current limiting, thermal protection, and short circuit protection to ensure reliable operation in case of voltage fluctuations.
To conclude, the MS32 20010-B inrush current limiter is an essential component in a wide variety of electrical applications due to its efficient performance and reliable protection capabilities. This device is suitable for high-voltage scenarios due to its current limiting capabilities, and it is easy to incorporate into existing control systems due to its compact design and high level of flexibility. Additionally, the MS32 20010-B inrush current limiter is designed to trip immediately in case of a surge, thanks to its set of internal components and advanced protection features.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
MS32 5R020 | Ametherm | 3.24 $ | 12253 | ICL 5 OHM 25% 20A 30MMInr... |
MS32 20010 | Ametherm | 3.24 $ | 4629 | ICL 20 OHM 25% 10A 30MMIn... |
MS32 10015 | Ametherm | 3.24 $ | 4119 | ICL 10 OHM 25% 15A 30MMIn... |
MS32 2R025 | Ametherm | 3.24 $ | 399 | ICL 2 OHM 25% 25A 30MMInr... |
MS32 0R540 | Ametherm | 3.24 $ | 1271 | ICL 0.5 OHM 25% 40A 30MMI... |
MS32 20008 | Ametherm | 3.24 $ | 418 | ICL 20 OHM 25% 8A 30MMInr... |
MS32 1R036-B | Ametherm | 3.24 $ | 980 | ICL 1 OHM 25% 36A 31MMInr... |
MS32 20010-B | Ametherm | 3.24 $ | 1229 | ICL 20 OHM 25% 10A 31MMIn... |
MS32 50006-B | Ametherm | 3.24 $ | 466 | ICL 50 OHM 25% 6A 30MMInr... |
MS32 5R020-B | Ametherm | 3.24 $ | 314 | ICL 5 OHM 25% 20A 31MMInr... |
MS32 1R036 | Ametherm | 3.24 $ | 239 | ICL 1 OHM 25% 36A 30MMInr... |
MS32 10015-B | Ametherm | 3.24 $ | 240 | ICL 10 OHM 25% 15A 31MMIn... |
MS32 20008-B | Ametherm | 3.24 $ | 151 | ICL 20 OHM 25% 8A 31MMInr... |
MS32 7R015-B | Ametherm | 3.24 $ | 72 | ICL 7 OHM 20% 15A 31MMInr... |
MS32 15012-B | Ametherm | 3.24 $ | 48 | ICL 15 OHM 25% 12A 31MMIn... |
MS32 2R025-B | Ametherm | 3.24 $ | 55 | ICL 2 OHM 25% 25A 31MMInr... |
MS32 0R540-B | Ametherm | 3.24 $ | 93 | ICL 0.5 OHM 25% 40A 31MMI... |
MS32 50006-L | Ametherm | 3.3 $ | 100 | INRUSH CURRENT LIMITERS 3... |
MS32 0R536-B | Ametherm | 3.24 $ | 25 | ICL 0.5 OHM 25% 36A 31MMI... |
MS32 0R536 | Ametherm | 2.68 $ | 1000 | ICL 0.5 OHM 25% 36A 30MMI... |
MS32 15012 | Ametherm | 2.68 $ | 1000 | ICL 15 OHM 25% 12A 30MMIn... |
MS32 50006 | Ametherm | 2.68 $ | 1000 | ICL 50 OHM 25% 6A 30MMInr... |
MS32 7R015 | Ametherm | 2.68 $ | 1000 | ICL 7 OHM 20% 15A 30MMInr... |
ICL 1.3 OHM 25% 8A 13.97MMInrush Current...
ICL 10 OHM 20% 5A 12MMInrush Current Lim...
ICL 4 OHM 20% 23A 30MMInrush Current Lim...
ICL 16 OHM 20% 4A 22MMInrush Current Lim...
ICL 16 OHM 25% 4A 19.56MMInrush Current ...
ICL 33 OHM 20% 2.5A 15MMInrush Current L...