| Allicdata Part #: | 486-3427-ND |
| Manufacturer Part#: |
0001.2021 |
| Price: | $ 2.02 |
| Product Category: | Circuit Protection |
| Manufacturer: | Schurter Inc. |
| Short Description: | FUSE CARTRIDGE 2A 500VAC DT II |
| More Detail: | N/A |
| DataSheet: | 0001.2021 Datasheet/PDF |
| Quantity: | 50 |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| 1 +: | $ 1.83960 |
| 10 +: | $ 1.71864 |
| 20 +: | $ 1.59894 |
| 50 +: | $ 1.43905 |
| 100 +: | $ 1.35910 |
| 200 +: | $ 1.27915 |
| 500 +: | $ 1.19921 |
| 1000 +: | $ 1.11926 |
| 5000 +: | $ 1.06329 |
| Applications: | -- |
| Size / Dimension: | 0.886" Dia x 1.969" L (22.50mm x 50.00mm) |
| Package / Case: | DT II |
| Mounting Type: | Holder |
| Breaking Capacity @ Rated Voltage: | 50kA |
| Operating Temperature: | -- |
| Approvals: | -- |
| Class: | D |
| Features: | -- |
| Series: | -- |
| Response Time: | -- |
| Voltage Rating - AC: | 500V |
| Current Rating: | 2A |
| Fuse Type: | Cartridge |
| Moisture Sensitivity Level (MSL): | -- |
| Part Status: | Active |
| Lead Free Status / RoHS Status: | -- |
| Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Specialty Fuses
The use of specialty fuses has been a growing trend in the electrical industry as they have become increasingly necessary components in device designs. Fuses are designed to protect circuit board components and provide added safety in the event of a power surge or interruption. Specialty fuses offer specific protection characteristics and features designed to improve device performance through more targeted and reliable current protection.
0001.2021 Application Field and Working Principle
0001.2021 specialty fuses are commonly used in industries such as automotive, aviation, and hazardous locations. These fuses are designed to offer improved safety and performance, allowing for a more reliable operation even in the harshest environments. The working principle of these fuses is to quickly disconnect an electric circuit to prevent further damage when a fault or an overload has occurred. This helps protect the electrical system from overload or short-circuit conditions, offering increased safety for personnel and equipment.
0001.2021 specialty fuses can be divided into two categories: high speed and slow blow. High speed fuses are designed to react quickly to an overload or short circuit, while slow blow fuses are designed to better withstand small overloads or surging currents. Depending on the application, either type can be used to provide reliable protection from damage or harm.
The fuse\'s current-carrying capability is determined by its rating, which is based on the diameter of the fuse element. The current rating is usually indicated on the end or side of the fuse, and is measured in amperes. Fuse ratings typically range from 5 to 100 Amps, but some specialty fuses are even higher in rating. It is important to select the correct fuse for the application, as an improperly sized fuse can lead to circuit overload or failure.
Specialty fuses are made with a variety of materials, including glass or ceramic, metal, and ceramic, and also come in varying sizes. Some fuses are designed for panel mounting, while others are designed to fit into a recess in the device or panel casing. Specialty fuses are designed for specific applications and conditions, including high temperature, extreme environments, and other extreme conditions. As such, they offer device protection and add extra safety in dangerous electrical environments.
An important factor when selecting specialty fuses is the fuse curve, which is the graph showing how the fuse operates when an overload or fault occurs. Fuse curves are generally categorized into fast blow and slow blow, depending on the characteristics of their reaction. Fuse curves indicate the amount of time it takes for the fuse to open the circuit when the device detects a fault. Fast blow curves indicate that the fuse will open the circuit quickly to protect the device, while slow blow curves indicate that the fuse will allow a certain amount of time before opening the circuit.
Selecting the right specialty fuse for an application is a critical decision, as an incorrectly sized fuse can cause failure or damage to the system. Careful consideration should be taken when choosing the size and type of fuse to ensure it provides the necessary protection from overload or short-circuit conditions, while also delivering reliable performance.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| 0001.1006 | Schurter Inc... | 0.57 $ | 13 | FUSE CERAMIC 1.6A 250VAC ... |
| 0001.2031 | Schurter Inc... | 3.32 $ | 50 | FUSE CARTRIDGE 63A 500VAC... |
| 813-22-030-30-000101 | Mill-Max Man... | 11.33 $ | 1000 | CONN SPRING CONT 30 POS .... |
| 816-22-022-10-000101 | Mill-Max Man... | 12.62 $ | 1000 | CONN SPRING-LOADED22 Posi... |
| 811-22-046-30-000101 | Mill-Max Man... | 14.59 $ | 1000 | CONN SPRING CONT 46 POS .... |
| 816-22-060-10-000101 | Mill-Max Man... | 22.17 $ | 1000 | CONN SPRING-LOADED60 Posi... |
| 61-000159-02 | Omron Automa... | 246.99 $ | 1000 | QX CBL M12-M12TOLB131 422... |
| 07-0001-11 | 3M | 100.64 $ | 1000 | THE 3M SPEEDGLAS AUTO-DA |
| 8N4SV76LC-0001CDI | IDT, Integra... | 12.14 $ | 1000 | IC OSC VCXO 125MHZ 6-CLCC... |
| 61-000165-02 | Omron Automa... | 132.22 $ | 1000 | QX CBL SER M12 PLG SCRW D... |
| EAGLE 20-00011 | Hirschmann | 1.39 $ | 1000 | EAGLE20-0400999TT999SK9V9... |
| 995-0001-071 | ITT Cannon, ... | 0.69 $ | 1000 | TOOLS |
| D4B-0001N | Omron Automa... | 0.0 $ | 1000 | SWITCH LIMIT STANDARD LEV... |
| 202312-0001 | Molex, LLC | 118.93 $ | 10 | INSPECTOR IND PRO CO DETE... |
| PPT2-0001DGW5VS | 0.69 $ | 1000 | PRESSURE TRANSDUCERPressu... | |
| JD3-0001NL | Pulse Electr... | 4.86 $ | 1864 | CONN MAGJACK 1PORT 1000 B... |
| 20021311-00014T4LF | Amphenol FCI | 0.83 $ | 2117 | CONN RECEPT 14POS DUAL VE... |
| 20021611-00012T4LF | Amphenol FCI | 1.18 $ | 1000 | HD EJECT VT THConnector H... |
| 0001.1010.TR | Schurter Inc... | 0.34 $ | 1000 | FUSE CERAMIC 4A 250VAC 5X... |
| 510-87-289-17-000101 | Preci-Dip | 7.81 $ | 1000 | CONN SOCKET PGA 289POS GO... |
| 812-22-053-30-000101 | Mill-Max Man... | 19.39 $ | 1000 | CONN SPRING 53POS SNGL .2... |
| GF-361-0001 | CW Industrie... | 0.74 $ | 1000 | SWITCH SLIDE 3PDT 3A 125V... |
| 20021212-00010T1LF | Amphenol FCI | 0.3 $ | 1000 | HD EJECT RA THConnector H... |
| 20021321-00012C1LF | Amphenol FCI | 0.41 $ | 1000 | CONN RCPT 12POS SMD GOLD1... |
| 20021521-00012C1LF | Amphenol FCI | 0.61 $ | 1000 | HD SMT SHRDConnector Head... |
| 20021621-00012T1LF | Amphenol FCI | 0.87 $ | 1000 | HD EJECT SMTConnector Hea... |
| 8N4SV75LC-0001CDI | IDT, Integra... | 12.14 $ | 1000 | IC OSC VCXO 125MHZ 6-CLCC... |
| DFK-33-0001 | Schurter Inc... | 6.27 $ | 1000 | COMMON MODE CHOKE 2A 2LN ... |
| 10124677-0001716LF | Amphenol FCI | 4.07 $ | 1000 | CONN SKT DIMM 288POS SMD2... |
| MAR1020-00014 | Hirschmann | 1.39 $ | 1000 | MAR1020-99MMMM99999999999... |
| 37161-00010 | Omron Automa... | 39.5 $ | 1000 | CART TRANSPORTER |
| 8N4SV76KC-0001CDI8 | IDT, Integra... | 10.88 $ | 1000 | IC OSC VCXO 125MHZ 6-CLCC... |
| PPT2-0001DGX2VS | 0.69 $ | 1000 | PRESSURE TRANSDUCERPressu... | |
| PPT2-0001GXK2VS | 0.69 $ | 1000 | PRESSURE TRANSDUCERPressu... | |
| 151053-0001 | Molex, LLC | 0.0 $ | 1000 | 11.00MM PITCH EXTREME GUA... |
| 0001.1024 | Schurter Inc... | 1.37 $ | 1000 | FUSE GLASS 1A 250VAC 3AB ... |
| 20021212-00010T4LF | Amphenol FCI | 0.32 $ | 1000 | HD EJECT RA THConnector H... |
| 10105229-0001LF | Amphenol FCI | 0.0 $ | 1000 | CONN MICRO SATA RCPT 15PO... |
| 3100 00011340 | Honeywell Se... | 66.01 $ | 1000 | THERMOSTAT 3100 SERIES HE... |
| 816-22-015-10-000101 | Mill-Max Man... | 11.22 $ | 1000 | CONN SPRING-LOADED15 Posi... |
FUSE CARTRIDGE 9A 600VAC/250VDC
FUSE SQUARE 50A 690VAC RECT
FUSE CRTRDGE 2.1KA 600VAC/480VDC
FUSE CRTRDGE 1.4KA 600VAC/480VDC
FUSE CARTRIDGE 150A 5.5KVAC
FUSE CARTRIDGE 10A 15.5KVAC CYL
0001.2021 Datasheet/PDF