Allicdata Part #: | F942-ND |
Manufacturer Part#: |
0217.500H |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | FUSE GLASS 500MA 250VAC 5X20MM |
More Detail: | N/A |
DataSheet: | 0217.500H Datasheet/PDF |
Quantity: | 1000 |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
Lead Free Status / RoHS Status: | Contains lead / RoHS non-compliant |
1 +: | 0.00000 |
Package / Case: | 5mm x 20mm |
DC Cold Resistance: | 0.207 Ohms |
Size / Dimension: | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) |
Color: | -- |
Operating Temperature: | -55°C ~ 125°C |
Approvals: | CCC, CE, CSA, K-MARK, SEMKO, UL, VDE |
Melting I²t: | 0.219 |
Breaking Capacity @ Rated Voltage: | 35A |
Mounting Type: | Holder |
Series: | 217 |
Response Time: | Fast |
Voltage Rating - AC: | 250V |
Current Rating: | 500mA |
Fuse Type: | Cartridge, Glass |
Moisture Sensitivity Level (MSL): | -- |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
0217.500H Fuses - Application Field and Working Principle
0217.500H fuses are used to protect installations, equipment and people from electrical overloads or shorts. Feeling the pressure to optimize circuit protection or replace existing devices, many designers and installation technicians are turning to 0217.500H fuses. Many of these applications, of course, have to do with general industry, but the number of uses is increasing quickly, especially in automobiles.
0217.500H fuses are generally made of impacted metals in several forms. The cross-section contact areas are generally copper, silver and other materials, and temperatures between 70°C and 200°C. The metallic material is compressed between a glass-fiber tube and the contacts, making it hold until certain current reaches the terminals. This current flow causes the compressed material to increase its temperature and burn. When the temperature reaches a certain point, the fuse blows and breaks the connection. It is a fast-acting fuse.
0217.500H fuses are most commonly used in electrical systems where the currents need to be limited. Their function is to isolate the main circuit and break the connection before it reaches the danger levels, therefore the installation. The current-resistance behavior makes them the perfect choice for high-current duties and applications.
The main application area for 0217.500H fuses is general electrical installations. The three key elements here are reducing the damage caused by a fault, providing protection from direct contact and preventing fire from occurring. Automobile applications are also important, because these machines are equipped with a number of electronic devices and computers that require high-current fuses.
The working principle of the 0217.500H fuse is similar to that of other fast-acting fuses, but it adds a bit of security thanks to its design. 0217.500H fuses are designed in a way that, at fixed current, the fuse element forms an arched lump in the middle of the fuse. This arched shape keeps the element center isolated, so that any possible fault or arc at fault conditions will only cause the fuse to open at that location, hence preventing the entire fuse from being destroyed.
0217.500H fuses are also particularly useful in environments exposed to shocks and vibrations, as the plastic material of the fuse significantly reduces the possibility of breaking and sparking due to physical stress. In addition, they can be used in devices that require a combination of DC and AC current, due to its good tolerance to change in current flow.
In addition to using 0217.500H fuses to protect against overloads or electrical short circuits, they are also used to protect against excessive electrical flow, sudden voltage fluctuations, overvoltage and arc faults. As users\' safety is often at stake, it is important for users to understand that there are certain applications for which 0217.500H fuses are the best choice, as they can easily be replaced after an overload.
In conclusion, 0217.500H fuses are the most reliable type of fuse for applications such as regular electrical installations, as well as for major appliances and automobiles. Thanks to its design, manufacturing and stress-resistant properties, it offers superior protection even in the most extreme conditions.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
0217900000 | Weidmuller | 15.49 $ | 1000 | DIN RAIL 15MMX5.5MM SLOTT... |
0217160000 | Weidmuller | 4.41 $ | 1000 | CONN TERM BLK FEED THRU 1... |
120110-0217 | ITT Cannon, ... | 1.89 $ | 230 | DUMMY RCPT FOR APD 1-7WAY |
ECA-0217 | TE Connectiv... | 4.16 $ | 1000 | BACKSHELLS |
0217.032HXP | Littelfuse I... | 1.3 $ | 30214 | FUSE GLASS 32MA 250VAC 5X... |
0217005.MXP | Littelfuse I... | 0.23 $ | 4642 | FUSE GLASS 5A 250VAC 5X20... |
0217002.MXP | Littelfuse I... | 0.23 $ | 2588 | FUSE GLASS 2A 250VAC 5X20... |
02171.25MXP | Littelfuse I... | 0.23 $ | 2399 | FUSE GLASS 1.25A 250VAC 5... |
0217015.MXP | Littelfuse I... | 0.23 $ | 1918 | FUSE GLASS 15A 250VAC 5X2... |
0217015.HXP | Littelfuse I... | 0.25 $ | 12845 | FUSE GLASS 15A 250VAC 5X2... |
0217002.HXP | Littelfuse I... | 0.25 $ | 9665 | FUSE GLASS 2A 250VAC 5X20... |
0217010.HXP | Littelfuse I... | 0.25 $ | 7307 | FUSE GLASS 10A 250VAC 5X2... |
0217005.HXP | Littelfuse I... | 0.25 $ | 6142 | FUSE GLASS 5A 250VAC 5X20... |
0217008.HXP | Littelfuse I... | 0.25 $ | 6207 | FUSE GLASS 8A 250VAC 5X20... |
021702.5HXP | Littelfuse I... | 0.25 $ | 5657 | FUSE GLASS 2.5A 250VAC 5X... |
0217004.HXP | Littelfuse I... | 0.25 $ | 2036 | FUSE GLASS 4A 250VAC 5X20... |
02173.15HXP | Littelfuse I... | 0.25 $ | 1064 | FUSE GLASS 3.15A 250VAC 5... |
0217010.MXEP | Littelfuse I... | 0.65 $ | 1404 | FUSE GLASS 10A 250VAC 5X2... |
0217.080MXBP | Littelfuse I... | 2.77 $ | 1000 | FUSE GLASS 80MA 250VAC 5X... |
0217.063MXBP | Littelfuse I... | 2.77 $ | 1000 | FUSE GLASS 63MA 250VAC 5X... |
0217.050MXBP | Littelfuse I... | 2.77 $ | 1000 | FUSE GLASS 50MA 250VAC 5X... |
0217.100MXBP | Littelfuse I... | 2.77 $ | 1000 | FUSE GLASS 100MA 250VAC 5... |
0217.315VXP | Littelfuse I... | 3.25 $ | 1000 | FUSE GLASS 315MA 250VAC 5... |
0217.400VXP | Littelfuse I... | 3.25 $ | 1000 | FUSE GLASS 400MA 250VAC 5... |
0217.250VXP | Littelfuse I... | 3.25 $ | 1000 | FUSE GLASS 250MA 250VAC 5... |
0217.032H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 32MA 250VAC 5X... |
0217.040H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 40MA 250VAC 5X... |
0217.050H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 50MA 250VAC 5X... |
0217.063H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 63MA 250VAC 5X... |
0217.080H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 80MA 250VAC 5X... |
0217.100H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 100MA 250VAC 5... |
0217.125H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 125MA 250VAC 5... |
0217.630H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 630MA 250VAC 5... |
0217.800H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 800MA 250VAC 5... |
0217001.H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 1A 250VAC 5X20... |
02171.25H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 1.25A 250VAC 5... |
021701.6H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 1.6A 250VAC 5X... |
0217002.H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 2A 250VAC 5X20... |
021702.5H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 2.5A 250VAC 5X... |
02173.15H | Littelfuse I... | 0.0 $ | 1000 | FUSE GLASS 3.15A 250VAC 5... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL