Allicdata Part #: | 203-2-1-64F-1251-F-1-21-A-ND |
Manufacturer Part#: |
203-2-1-64F-1251-F-1-21-A |
Price: | $ 157.49 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIR BRKR .125A 32VDC ROCKER |
More Detail: | N/A |
DataSheet: | ![]() |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
3 +: | $ 143.17000 |
Series: | 203 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Voltage Rating - AC: | 250V |
Voltage Rating - DC: | 32V |
Number of Poles: | 1 |
Actuator Type: | Rocker |
Illumination: | Red |
Illumination Voltage (Nominal): | 3V |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
A Circuit Breaker is an electrical circuit protection device whose purpose it is to protect other electrical components from overloads or short circuits. The 203-2-1-64F-1251-F-1-21-A Circuit Breaker is a commonly used circuit breaker in a variety of applications. The 203-2-1-64F-1251-F-1-21-A circuit breaker is used in many different industries, and it is used to protect equipment such as motors, pumps, and HVAC systems from over voltage and short circuits. This particular model is a standard trip mini circuit breaker, and it is rated at two amperes (2A). It is UL approved and CSA listed.
The 203-2-1-64F-1251-F-1-21-A circuit breaker is a thermal-magnetic circuit breaker. In other words, it is a combination of a thermal and magnetic trip unit. A thermal trip unit senses the amount of heat produced by the current flow within the circuit, and it will trip the breaker if the current draw exceeds the rated amperage of the breaker. The magnetic trip unit senses the amount of magnetic force generated by the current flow, and it will trip the breaker if the magnetic force exceeds the rated amperage of the breaker. The thermal trip unit will kick in faster than the magnetic trip unit, so it acts as an additional layer of protection.
In order to ensure that the 203-2-1-64F-1251-F-1-21-A circuit breaker will trip in the event of an overload or short circuit, it must be wired into the circuit correctly. This circuit breaker requires two wires: the input wire and the output wire. The input wire should be connected to the power source, such as an AC power outlet, and the output wire should be connected to the device that is to be protected, such as a motor or a pump. It is also important to ensure that the wires are connected properly and that the terminals are tight. A loose connection could cause the breaker to reset, which means it won’t be able to protect the device.
The 203-2-1-64F-1251-F-1-21-A circuit breaker is a great choice for many applications. It is extremely durable, UL approved and CSA listed, and it is a single-pole breaker with a two-amp rating. It is also designed to be incredibly reliable and easy to install, so it can be used in a variety of applications. Whether the application is industrial, commercial, or residential, this circuit breaker can be used to provide the necessary protection.
The specific data is subject to PDF, and the above content is for reference
CIRCUIT BREAKER MAG-HYDR LEVER

CIRCUIT BREAKER MAG-HYDR LEVER

CIR BRKR MAG-HYDR 200A 160VDC

CIR BRKR MAG-HYDR

CIRC BRKR THRM

CIR BRKR MAG-HYDR LEVER 10A