| Allicdata Part #: | 203-222-1-43-502-4-1-1-ND |
| Manufacturer Part#: |
203-222-1-43-502-4-1-1 |
| Price: | $ 427.13 |
| Product Category: | Circuit Protection |
| Manufacturer: | Sensata-Airpax |
| Short Description: | CIR BRKR 5A 32VDC ROCKER |
| More Detail: | N/A |
| DataSheet: | 203-222-1-43-502-4-1-1 Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 3 +: | $ 388.29800 |
| Series: | 203 |
| Part Status: | Active |
| Lead Free Status / RoHS Status: | -- |
| Breaker Type: | Magnetic |
| Moisture Sensitivity Level (MSL): | -- |
| Current Rating: | 5A |
| Voltage Rating - AC: | 250V |
| Voltage Rating - DC: | 32V |
| Number of Poles: | 3 |
| Actuator Type: | Rocker |
| Illumination: | Neon |
| Illumination Voltage (Nominal): | 120V |
| Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are overcurrent protective devices that are designed to provide safety for electrical systems. They are used in applications where currents should be limited in order to avoid equipment damage and potentially prevent serious personal injury. The 203-222-1-43-502-4-1-1 application field and working principle of circuit breakers can roughly be divided into three types including thermal, magnatic and trip circuit breakers.
Thermal Circuit Breakers
Thermal circuit breakers are designed with a bi-metal strip, which bend when hot, thereby breaking the electrical circuit. These thermal breakers are designed to reset automatically when the current is reduced to a low enough level that the bi-metal strip cools and the spring force straightens out. A further advantage is that these breakers have an inverse time delay allowing lower current levels to be shut-off quicker than higher current levels.
Magnetic Circuit Breakers
Magnetic circuit breakers rely on a solenoid and contacts, which are used to open the circuit. When current increases, the increased magnetic field forces the solenoid core to attract a latch and open the contacts. These breakers also have an inverse time delay, allowing lower current levels to be shut-off quicker than higher current levels. Magnetic breakers are protected from nuisance tripping and cannot reset until a technician investigates and clears the fault.
Trip Circuit Breakers
Trip circuit breakers are used whenever the power needs to be disconnected from equipment in an instant. These breakers can be manually operated by pushing a pushbutton, or be automated with a voltage or current supply. Trip circuit breakers have a low level of contact resistance and are able to switch heavy currents quickly without over- fluxing the contacts.
The 203-222-1-43-502-4-1-1 application field and working principle of circuit breakers should be considered when designing an electrical system. Each type of breaker offers unique advantages that can help keep people, equipment, and buildings safe. When in doubt, always consult a qualified electrician or engineer to ensure that the plan is properly executed.
The specific data is subject to PDF, and the above content is for reference
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A
203-222-1-43-502-4-1-1 Datasheet/PDF