| Allicdata Part #: | ACX1454-ND |
| Manufacturer Part#: |
222197 |
| Price: | $ 2.53 |
| Product Category: | Connectors, Interconnects |
| Manufacturer: | Amphenol RF Division |
| Short Description: | CONN F PLUG STR 75 OHM CRIMP |
| More Detail: | F Type Connector Plug, Male Pin 75 Ohm Free Hangin... |
| DataSheet: | 222197 Datasheet/PDF |
| Quantity: | 90 |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| 1 +: | $ 2.29950 |
| 10 +: | $ 2.20752 |
| 25 +: | $ 2.02356 |
| 50 +: | $ 1.93158 |
| 100 +: | $ 1.83960 |
| 250 +: | $ 1.60965 |
| 500 +: | $ 1.56366 |
| 1000 +: | $ 1.33371 |
| 2500 +: | $ 1.24173 |
| Frequency - Max: | 2GHz |
| Insertion Loss: | -- |
| Mating Cycles: | 500 |
| Center Contact Material: | Brass |
| Operating Temperature: | -- |
| Dielectric Material: | Polytetrafluoroethylene (PTFE) |
| Center Contact Plating: | Gold |
| Body Finish: | Nickel |
| Body Material: | Brass |
| Includes: | 3 pcs - 1 Connector, 1 Contact, 1 Ferrule |
| Ingress Protection: | -- |
| Housing Color: | Silver |
| Features: | -- |
| Number of Ports: | 1 |
| Series: | -- |
| Fastening Type: | Threaded |
| Cable Group: | RG-58, 58A, 58B, 58C, 141, 303, LMR-195, Belden B7806A, 9907 |
| Mounting Feature: | -- |
| Mounting Type: | Free Hanging (In-Line) |
| Impedance: | 75 Ohm |
| Shield Termination: | Crimp |
| Contact Termination: | Crimp or Solder |
| Connector Type: | Plug, Male Pin |
| Connector Style: | F Type |
| Moisture Sensitivity Level (MSL): | -- |
| Part Status: | Active |
| Lead Free Status / RoHS Status: | -- |
| Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Coaxial Connectors (RF), or commonly referred to as RF connectors are essential components for any radio frequency system and can be used for a wide variety of applications, including: linking antennas to radio transmitters, connecting two points on a cable, etc. The 222197 RF coaxial connector is part of this family and is used in particular for connecting two pieces of coaxial cable. Below, we\'ll delve into this application field and discuss the working principle of the 222197 coaxial connector.
In terms of application field, the 222197 coaxial connector is mainly used in the fields of radio frequency (RF) communication, CATV signal transmission, broadband signal transmission, satellite transmission, antenna feeder system cables and base station feeders. This is due to the low connection loss and good mechanical and electrical stability offered by the connector. It can also be used in all types of military and space applications for both high-frequency and low-frequency signals.
The 222197 coaxial connector is designed to connect two pieces of coaxial cable, one male and the other female. It is composed of two metal components. The male component consists of a solid pin and a threaded body, while the female component contains ridges and an inner threaded insert, making it easy to attach to other components. The coupling mechanism is simple, ensuring a reliable and secure connection.
Regarding its working principle, the 222197 coaxial connector uses the basic mechanism of electrical connection. This is done by the two contact surfaces, the internal pins and the connector housings, which are in direct contact when connected. The shape of the surfaces makes sure that the connection is strong, secure, and free from any noise that could interfere with the signal. In addition, the 222197 features an incased protective shell that helps to shield the connector from any external environmental forces such as EMI and RFI. This helps to ensures that the connections remain reliable and provide stable signal.
Finally, the 222197 coaxial connector is a great choice for a variety of applications because of its high performance, efficiency, and reliability. It features a low insertion and return loss, which helps to improve the reliability of the communication system and the signal stability of the connected components. Furthermore, it is designed to be waterproof, making it suitable for outdoor use. Additionally, its locking mechanism ensures that it is easy to make and break connections, providing a quick and convenient way to install and maintain the connection. The 222197 coaxial connector is thus a great choice for anyone looking for a reliable and efficient connector for their application.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| 2221682-1 | TE Connectiv... | 44.67 $ | 1000 | FAS-T PROT. COVER, RATCHE... |
| 2221916-1 | TE Connectiv... | 535.6 $ | 1000 | RF C/A, SMA STR-R/A P, 21... |
| IPG-22219-G | Bud Industri... | 0.97 $ | 19 | GRY CABLE GLAND .47-.59" |
| KJD17-22213-112 | E-Switch | 5.84 $ | 1000 | SWITCH PUSH DPST 16A 120V... |
| 10131318-22211G0LF | Amphenol FCI | 1.32 $ | 1000 | MINITEK PWR 4.2 HCC RA |
| 2221478-3 | TE Connectiv... | 51.76 $ | 1000 | FAS-T PROT. COVER,RATCHET... |
| 222154 | Amphenol RF ... | 0.69 $ | 1372 | CONN TERMINATOR PLUG F 75... |
| 10132449-2221GLF | Amphenol FCI | 0.54 $ | 1000 | MINITEK PWR 3.0 HCC HDRCo... |
| 2221289-6 | TE Connectiv... | 61.56 $ | 1000 | RF C/A, SMPM FL MNT J-SMA... |
| 2221612-2 | TE Connectiv... | 47.63 $ | 1000 | CIRC. HD PLUG WITH PIN CO... |
| F05E-222146R | Harwin Inc. | 0.0 $ | 1000 | CONN FPC BOTTOM 22POS 0.5... |
| 222194 | Amphenol RF ... | 3.14 $ | 1000 | CONN F PLUG STR 75OHM CRI... |
| 2221760-4 | TE Connectiv... | 54.24 $ | 1000 | CONN D-SUB HD RCPT 62P ST... |
| 222146 | Amphenol RF ... | 4.96 $ | 303 | CONN F JACK STR 75 OHM SO... |
| 2221.000.01 | FEIG ELECTRO... | 0.0 $ | 1000 | ID ISC.MR200-E ETHERNET M... |
| TN-222159-15-9 | TE Connectiv... | 0.0 $ | 1000 | LABEL ID PRODUCTS |
| 2221705-4 | TE Connectiv... | 104.78 $ | 1000 | BODY, 2 POSITION RF MODUL... |
| 2221861-1 | TE Connectiv... | 91.39 $ | 1000 | DC, 7ROW, CENTER, MULTIGI... |
| 2221760-2 | TE Connectiv... | 37.74 $ | 1000 | CONN D-SUB HD RCPT 26P ST... |
| 10132450-2221GLF | Amphenol FCI | 0.41 $ | 1000 | MINITEK PWR 3.0 HCC HDRCo... |
| 2221235-1 | TE Connectiv... | 49.43 $ | 1000 | SZ3 PLUG, FREEHANGING, 12... |
| 10131318-2221100LF | Amphenol FCI | 1.29 $ | 1000 | MINITEK PWR 4.2 HCC RA |
| 2221824-1 | TE Connectiv... | 473.8 $ | 1000 | A600, 100 POSITION INSERT... |
| ATH 2221 | Astro Tool C... | 94.23 $ | 1000 | TOOL REMOVAL 8 GA |
| 222128-10 | Amphenol RF ... | 2.15 $ | 130 | CONN F RCPT R/A 75 OHM PC... |
| 2221-H-RC | Bourns Inc. | 1.72 $ | 1000 | FIXED IND 560UH 2.2A 210 ... |
| 10127820-2221GLF | Amphenol FCI | 0.91 $ | 1000 | MINITEK PWR4.2 VT HEADER |
| IPG-22216-BPG | Bud Industri... | 2.84 $ | 18 | BND PRF GRY CABLE GLAND .... |
| 222131 | Amphenol RF ... | 1.8 $ | 665 | CONN F RCPT R/A 75 OHM PC... |
| 222180 | Amphenol RF ... | 4.73 $ | 58 | CONN F RCPT R/A 75 OHM PC... |
| 222128-11 | Amphenol RF ... | 1.86 $ | 1000 | CONN F RCPT R/A 75 OHM PC... |
| 222114-10 | Amphenol RF ... | 3.26 $ | 1042 | CONN F JACK STR 75 OHM SO... |
| 2221425-1 | TE Connectiv... | 0.69 $ | 1000 | SZ3 PLUG,150/150/59/11Q11... |
| 2221946-1 | TE Connectiv... | 378.39 $ | 1000 | SIZE 2 REC ASSY, 150/BLAN... |
| 2221952-1 | TE Connectiv... | 553.38 $ | 1000 | SIZE 2 PLUG ASSY, 150/BLA... |
| 2221760-6 | TE Connectiv... | 69.22 $ | 1000 | CONN D-SUB HD RCPT 104POS... |
| 2221 G7WU1000 | Belden Inc. | 686.82 $ | 1000 | 1 PR #26 FHDPE BRD PVCCon... |
| 2221548-1 | TE Connectiv... | 0.69 $ | 1000 | ARINC 600, PLUG ASSY, SZ2... |
| IPG-22211-BPG | Bud Industri... | 1.94 $ | 3 | BND PRF GRY CABLE GLAND .... |
| WP-222159-15-9 | TE Connectiv... | 0.01 $ | 1000 | LABEL ID PRODUCTS |
CONN SMB PLUG STR 50OHM CRIMPSMB Connect...
CONN MINI UHF PLUG STR 50 OHMUHF, Mini C...
CONN TNC PLUG R/A 50 OHM CRIMPTNC Connec...
CONN SMB PLUG R/A 50 OHM SOLDERSMB Conne...
CONN N JACK STR 50 OHM CRIMPN Type Conne...
CONN BNC PLUG STR 75 OHM CRIMPBNC Connec...
222197 Datasheet/PDF