| Allicdata Part #: | 229-2-1-66-6-9-10-ND |
| Manufacturer Part#: |
229-2-1-66-6-9-10 |
| Price: | $ 115.68 |
| Product Category: | Circuit Protection |
| Manufacturer: | Sensata-Airpax |
| Short Description: | CIR BRKR MAG-HYDR 10A 277VAC |
| More Detail: | N/A |
| DataSheet: | 229-2-1-66-6-9-10 Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 3 +: | $ 105.16600 |
| Series: | 229 |
| Part Status: | Active |
| Lead Free Status / RoHS Status: | -- |
| Breaker Type: | Magnetic (Hydraulic Delay) |
| Moisture Sensitivity Level (MSL): | -- |
| Current Rating: | 10A |
| Voltage Rating - AC: | 277V |
| Number of Poles: | 2 |
| Actuator Type: | Lever |
| Illumination: | -- |
| Illumination Voltage (Nominal): | -- |
| Mounting Type: | DIN Rail |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit Breakers
Circuit breakers are designed to protect circuits from short circuits, overloads, and other electrical problems that could cause damage to components and devices, and to reduce the risk of potential electrical fires. They come in a variety of designs and types, and include the 229-2-1-66-6-9-10 application field and working principle.
229-2-1-66-6-9-10 Application Field and Working Principle
The 229-2-1-66-6-9-10 is an air magnetic circuit breaker. It is designed to protect circuits from electrical surges caused by faults or other dangerous conditions. It is used in a wide variety of applications, including motor control centers, over-load protection, and machine tools.
The 229-2-1-66-6-9-10 is comprised of two components- a mechanism to trip the circuit breaker and an automatic reset. The device is activated when there is an over current in the circuit following a fault or failure. The trip mechanism then opens the circuit, and the reset allows the breaker to automatically re-close when the fault is cleared. The breaker is designed to be able to trip the circuit, even when nominal or minimal current is present.
The 229-2-1-66-6-9-10 has two contacts that should be kept in the closed position to ensure that the breaker is operable. The contacts are connected in series between the power source and the output device, and are able to both open and close. When the contacts are closed, current flows through the device and the output device is able to function. If a fault occurs, the circuit breaker will trip and the contacts will open, thus preventing any further current from passing through the device.
The 229-2-1-66-6-9-10 also features an indicator to show when the contacts have opened. The indicator, which is typically a red or yellow LED, is located on the device’s outside housing. It is lit when the contacts are open, and not lit when the contacts are closed. This allows for easy detection of tripped circuit breakers.
In summary, the 229-2-1-66-6-9-10 air magnetic circuit breaker is used to open and close electrical circuits in a variety of applications, including motor control centers, over-load protection, and machine tools. It trips the circuit when an over-current is detected, and can automatically reset when the fault is cleared. It has clearly visible indicators that allow for easy detection of tripped circuit breakers.
The specific data is subject to PDF, and the above content is for reference
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A
229-2-1-66-6-9-10 Datasheet/PDF