Allicdata Part #: | 277-8191-ND |
Manufacturer Part#: |
2800846 |
Price: | $ 32.96 |
Product Category: | Circuit Protection |
Manufacturer: | Phoenix Contact |
Short Description: | CIR BRKR 500MA 277VAC 50VDC |
More Detail: | N/A |
DataSheet: | 2800846 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
1 +: | $ 29.95650 |
Specifications
Series: | CB |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal Magnetic |
Current Rating: | 500mA |
Voltage Rating - AC: | 277V |
Voltage Rating - DC: | 50V |
Number of Poles: | 1 |
Actuator Type: | Slide Switch |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Holder |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit Breakers: 2800846 Application Field and Working PrincipleCircuit breakers have a long history of use in electrical applications, having been used for decades to protect against damage caused by power outages, short circuits and other abnormal conditions in electrical circuits. This 2800846 Application Field and Working Principle summarises the application field and working principle of circuit breakers. What is a Circuit Breaker?A circuit breaker is an electrical safety device that stops the flow of current in an overloaded electrical circuit. Circuit breakers are designed to sense abnormal current levels, and in the event that dangerous levels of current are detected, the breaker trips and automatically shuts off power to the circuit. Among other things, circuit breakers are used to protect households, commercial and industrial establishments, and fire department buildings against the risk of electrical fire or damage due to electrical overloads. Application Field of Circuit Breakers 2800846Circuit breakers are used in a wide variety of applications, ranging from residential to commercial and industrial applications. For example, in residential settings, circuit breakers are used to protect home electrical systems from overloading and shortcircuiting. Circuit breakers can also be used to protect against surges in electrical current, which can damage electrical appliances and devices.In commercial and industrial settings, circuit breakers are used to protect more complex electrical systems that may use large amounts of power. These systems may include large electrical machines, computers, or other components that require large amounts of power. Circuit breakers can also be used to protect against electrical fires and damages caused by power surges.Working Principle of 2800846 Circuit BreakersThe working principle of a circuit breaker is simple. When a circuit breaker detects an abnormal increase in the electrical current passing through the circuit, it trips and shuts off the electrical supply to the circuit. This prevents damage to the circuit and reduces the risk of fire or other electrical hazards.One of the most important components of a circuit breaker is the tripping mechanism. This is the mechanism that determines when the circuit breaker will trip. Most circuit breakers use a bimetallic strip as the tripping mechanism, which is a strip made of two different metals that expand and contract at different rates when exposed to changes in temperature. When the current flow in the circuit increases too quickly, the bimetallic strip will expand and cause the circuit breaker to trip, shutting off the power to the circuit.The other main component of a circuit breaker is the reset mechanism. This is the mechanism that allows the user to reset the circuit breaker after it has tripped. In most cases, this is done by pressing the reset button on the circuit breaker, which mechanically pushes the tripping mechanism back into place so that the breaker can be reset and the power to the circuit restored.ConclusionCircuit breakers are an important safety device, and the 2800846 Application Field and Working Principle summarises their application field and working principle. Circuit breakers are used in a variety of settings to protect against electrical fires, surges and other abnormal conditions in electrical circuits, and their working principle is based on a bimetallic strip that trips when the current flow in the circuit increases too quickly. By understanding the application field and working principle of circuit breakers, individuals can ensure the safe operation of their electrical systems.The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "2800" Included word is 29
Part Number | Manufacturer | Price | Quantity | Description |
---|
2800-253424 | Knowles | 2.51 $ | 1000 | SWITCH PUSHBUTTON |
2800-253374 | Knowles | 2.51 $ | 1000 | SWITCH PUSHBUTTON |
2800-253410 | Knowles | 3.26 $ | 1000 | SWITCH PUSHBUTTON |
2800-253486 | Knowles | 2.51 $ | 1000 | SWITCHES |
2800-253586 | Knowles | 4.1 $ | 7 | SWITCHES |
2800-253301 | Knowles | 2.96 $ | 1000 | SWITCH PUSHBUTTON |
2800-253325 | Knowles | 4.1 $ | 82 | SWITCHES |
2800-254013 | Knowles | 6.1 $ | 1000 | SWITCH PUSHBUTTON |
2800-253907 | Knowles | 2.73 $ | 1000 | SWITCH PUSHBUTTON |
2800-253377 | Knowles | 2.77 $ | 1000 | SWITCH PUSHBUTTON |
2800-253915 | Knowles | 3.21 $ | 1000 | SWITCH PUSHBUTTON |
2800-253598 | Knowles | 3.93 $ | 1000 | SWITCH PUSHBUTTON |
2800-253947 | Knowles | 3.21 $ | 1000 | SWITCH PUSHBUTTON |
2800-253788 | Knowles | 3.21 $ | 1000 | SWITCH PUSHBUTTON |
2800-253591 | Knowles | 2.96 $ | 1000 | SWITCH PUSHBUTTON |
2800-253633 | Knowles | 4.63 $ | 1000 | SWITCH PUSHBUTTON |
CVCO55BE-2000-2800 | Crystek Corp... | 12.26 $ | 1000 | OSC VCO 2000-2800MHZ SMD ... |
CVCO55BE-2650-2800 | Crystek Corp... | 13.72 $ | 1000 | OSC VCO 2650-2800MHZ SMD ... |
2800570 | Phoenix Cont... | 9.05 $ | 96 | CONN TERM BLK FEED THRU 1... |
248-2800-000 | ITT Cannon, ... | 225.39 $ | 6 | RP SHELL BKAC/D/E 3 RECPT... |
280007-1 | TE Connectiv... | 0.01 $ | 1000 | CONN SPLICE 600-3000 CMA ... |
1-280002-1 | TE Connectiv... | 0.01 $ | 1000 | CONN SPLICE 1500-5000 CMA... |
280007-2 | TE Connectiv... | 0.02 $ | 1000 | CONN SPLICE 600-3000 CMA ... |
280005-2 | TE Connectiv... | 0.02 $ | 1000 | CONN SPLICE 600-3000 CMA ... |
280099 | TE Connectiv... | 0.53 $ | 635 | CONN MALE TAB HSG 0.25 8P... |
3485-2800R | 3M | 2.68 $ | 1000 | CONN D-SUB JUNCT SHELL 36... |
3485-2800F | 3M | 4.86 $ | 1000 | CONN D-SUB JUNCT SHELL 36... |
280004-1 | TE Connectiv... | 0.03 $ | 1000 | CONN SPLICE 600-3000 CMA ... |
280002-1 | TE Connectiv... | 0.07 $ | 1000 | CONN SPLICE 1500-5000 CMA... |
Latest Products
UPG11-4038-10
CIRCUIT BREAKER MAG-HYDR LEVER
299-3-3283-14
CIRCUIT BREAKER MAG-HYDR LEVER
JLE-1-1REG4-52-3-B1-200-A...
CIR BRKR MAG-HYDR 200A 160VDC
IEGH666-1REC4-72-32.0-01-...
CIR BRKR MAG-HYDR
483-G641-K1M1-A1S0ZN-5A
CIRC BRKR THRM
IEG111-1-52-10.0-01-V
CIR BRKR MAG-HYDR LEVER 10A