30-00805 Cables, Wires |
|
| Allicdata Part #: | T1369-153-ND |
| Manufacturer Part#: |
30-00805 |
| Price: | $ 96.01 |
| Product Category: | Cables, Wires |
| Manufacturer: | Tensility International Corp |
| Short Description: | CBL 2CON 300V 26AWG BLK 153M |
| More Detail: | 2 Conductor Multi-Conductor Cable Black 26 AWG 50... |
| DataSheet: | 30-00805 Datasheet/PDF |
| Quantity: | 14 |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| 1 +: | $ 87.28020 |
| 5 +: | $ 71.40910 |
| 10 +: | $ 55.54020 |
| 25 +: | $ 47.60610 |
| 50 +: | $ 44.43230 |
| 100 +: | $ 41.25860 |
| Shield Type: | -- |
| Shield Coverage: | -- |
| Shield Material: | -- |
| Conductor Insulation: | -- |
| Jacket (Insulation) Thickness: | 0.0157" (0.400mm) |
| Usage: | -- |
| Operating Temperature: | -10°C ~ 105°C |
| Voltage: | 300V |
| Features: | -- |
| Ratings: | UL Style 2651 |
| Jacket Color: | Black |
| Length: | 502.0' (153.0m) |
| Series: | -- |
| Jacket (Insulation) Diameter: | 0.106" (2.69mm) |
| Jacket (Insulation) Material: | Poly-Vinyl Chloride (PVC) |
| Conductor Material: | Copper, Tinned |
| Conductor Strand: | 7/0.0063" |
| Wire Gauge: | 26 AWG |
| Number of Conductors: | 2 |
| Moisture Sensitivity Level (MSL): | -- |
| Cable Type: | Multi-Conductor |
| Lead Free Status / RoHS Status: | -- |
| Part Status: | Active |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Multiple Conductor Cables are electrical cables consisting of two or more individually insulated conductors within one overall sheath. The most common type, and the one referred to by the 30-00805 marking, is the twisted pair cable. This particular type of cable has two insulated conductors, traditionally of copper, twisted together. The insulation between each individual conductor is there to protect against shock and unwanted contact that could result in an electrical short.
The twisting of the two wires serves two main purposes. Firstly, the twist provides a measure of electromagnetic shielding, as it reduces the ability of outside electromagnetic fields to induce a current flow in the cable. This helps to reduce crosstalk between multiple pairs of cables. The second advantage of the twist is that it helps to reduce the susceptibility of the cable to radio frequency interference. This feature helps to ensure that the signals sent down the cable remain as clean and clear as when they were sent.
These twisted pair cables are commonly used for the transmission of data, such as that used in the field of Ethernet networking. The cabling of an Ethernet network is made from twisted pair cables, as the twisted pair design helps to reduce crosstalk between each of the cables and the electromagnetic shielding reduces the risk of outside interference affecting the signal.
These cables are also used extensively in the transmission of power over medium-to-long distances. The cables form an integral part of any electrical power grid, serving to transport electricity from power stations to areas in need of it. The insulated conductors, along with the reduced risk of electrical shock, makes it possible to move large amounts of electrical power safely over adequate distances.
The use of twisted pair cables is not limited to Ethernet networking and power distribution though. These cables are used in a variety of contexts, from telephone systems to factory automation. Their general nature allows them to be applied to almost any situation with relative ease.
The function of the 30-00805 marking on a multiple conductor cable is to gauge its overall performance. This marking helps to identify the quality of the cable and the amount of interference its insulation is protecting against. The performance requirements of this particular marking classifies it as a Cat-5 type of cable, meaning that it is suitable for use in applications such as Ethernet networking.
The 30-00805 marking also serves as a standard of quality. By meeting the performance requirements set out by the standard, it helps to ensure that the transmission of data through the cable is as clean and uninterrupted as possible.
In conclusion, the 30-00805 marking of twisted pair cables identifies them as belonging to the multiple conductor cable category. They are mainly used for the transmission of data and power. The twisting of the conductors helps them to reduce crosstalk and interference, and the 30-00805 marking helps to gauge their overall performance, making sure that the cables are suitable for use in a variety of applications.
The specific data is subject to PDF, and the above content is for reference
CABLE 4COND 16AWG YELLOW 250'4 Conductor...
CBL 5E COPPER VIOL FLAME RET PVCConducto...
CABLE 6COND 16AWG BLACK 100'6 Conductor ...
MULTI-PAIR 100COND 28AWG 328.1'100 (50 P...
MULTI-PAIR 8COND 20AWG YEL 1000'8 (4 Pai...
CABLE 2COND 20AWG BLUE 100'2 (1 Pair Twi...
30-00805 Datasheet/PDF