Allicdata Part #: | 3120-F324-P7T1-W15DY4-15A-ND |
Manufacturer Part#: |
3120-F324-P7T1-W15DY4-15A |
Price: | $ 30.70 |
Product Category: | Circuit Protection |
Manufacturer: | E-T-A |
Short Description: | CIR BRKR THRM 15A 250VAC 50VDC |
More Detail: | N/A |
DataSheet: | 3120-F324-P7T1-W15DY4-15A Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
10 +: | $ 27.90210 |
Series: | 3120-F |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 15A |
Voltage Rating - AC: | 250V |
Voltage Rating - DC: | 50V |
Number of Poles: | 2 |
Actuator Type: | Rocker |
Illumination: | Orange |
Illumination Voltage (Nominal): | 185V |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit Breakers
A circuit breaker is an often automated electronic or mechanical switch designed to protect an electrical circuit from damage caused by overload, short circuit, or other fault condition. When an overload, short circuit, or other fault occurs, the circuit breaker trips, which disconnects the equipment - in this case, 3120-F324-P7T1-W15DY4-15A - from the power supply. This prevents damage to the circuit and the associated equipment.
Application
3120-F324-P7T1-W15DY4-15A circuit breakers are primarily used in commercial and industrial settings, such as factories, office buildings, data centers, power plants, and substations. They are used for a wide range of applications, from protecting individual motors, to isolating an entire section of the facility from the power grid.
Working Principle
The working principle of a 3120-F324-P7T1-W15DY4-15A circuit breaker is fairly straightforward. When a problem, such as an overload, short circuit, or other fault, occurs, the circuit breaker’s internal sensing mechanism detects the fault and trips, opening up a set of contacts. This disconnects the equipment from the power supply and prevents it from further damage.
The circuit breaker’s sensing mechanism may also be set to recognize a certain level of current flow or voltage drop. If this set level is exceeded, the circuit breaker trips and disconnects the equipment from the power supply. Many modern circuit breakers also have the ability to be reset, allowing the equipment to be reconnected to the power supply after the fault has been resolved.
In addition to protecting the associated equipment, circuit breakers also provide protection of the power supply. By tripping in the event of an overload or other fault, circuit breakers help to prevent power outages and equipment damage in the event of a large-scale failure.
Advantages of Using Circuit Breakers
One of the primary advantages of using circuit breakers is their ability to quickly disconnect an overloaded circuit. This reduces the risk of damage to both the equipment and the power supply, and helps to prevent fires in commercial and industrial settings. Additionally, circuit breakers are relatively simple to install and require minimal maintenance.
Another advantage of circuit breakers is their ability to be reset. After an overload, short circuit, or other fault has occurred, the circuit breaker can be reset and the equipment can be reconnected to the power supply. This is especially useful in situations where the fault is caused by a loose or faulty connection that can be easily remedied.
Finally, many modern circuit breakers offer features such as adjustable current levels, remote monitoring, and surge protection. These features can help provide added protection for sensitive equipment, and also aid in troubleshooting and monitoring of equipment.
Conclusion
3120-F324-P7T1-W15DY4-15A circuit breakers are an effective and cost-efficient method of protecting both the equipment and the power supply from overloads, short circuits, and other faults. The circuit breaker’s sensing mechanism quickly detects the fault and trips, disconnecting the equipment from the power supply and preventing further damage. Additionally, circuit breakers offer the advantage of being reset after the fault has been resolved, and many modern models offer features such as adjustable current levels, remote monitoring, and surge protection.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CVCO55BE-2732-3120 | Crystek Corp... | 13.72 $ | 1000 | OSC VCO 2732-3120MHZ SMD ... |
CRBV55BE-2710-3120 | Crystek Corp... | 58.21 $ | 1000 | VCO 2710-3120 MHZ REDBOX2... |
CRBV55BE-2732-3120 | Crystek Corp... | 65.98 $ | 1000 | VCO 2732-3120 MHZ REDBOX2... |
31204 | Parallax Inc... | 0.0 $ | 1000 | BOARD RELAY RC-4Board D2W... |
10062086-3120LF | Amphenol FCI | 3.72 $ | 1000 | CONN SKT SODIMM 144POS R/... |
AI-3120S | PUI Audio, I... | 0.0 $ | 1000 | AUDIO PIEZO INDICATOR PNL... |
AI-3120D | PUI Audio, I... | 0.0 $ | 1000 | AUDIO PIEZO INDICATOR PNL... |
BKAD2-155-31201-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 155PO... |
BKAD2-155-31201 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 155PO... |
3120-F22F-H7T1-SGRX-X3120-U0100M-4A | E-T-A | 49.41 $ | 1000 | CIR BRKR THRMMAG 4A 250VA... |
3120-F22F-H7T1-SGRX-X3120-U0100M-5A | E-T-A | 49.41 $ | 1000 | CIR BRKR THRMMAG 5A 250VA... |
3120-F22F-H7T1-SGRX-X3120-U0100M-8A | E-T-A | 49.41 $ | 1000 | CIR BRKR THRMMAG 8A 250VA... |
3120-F22F-H7T1-SGRX-X3120-U0101M-15A | E-T-A | 49.41 $ | 1000 | CIR BRKR 15A 250VAC 50VDC |
3120-F22F-H7T1-SGRX-X3120-U0101M-8A | E-T-A | 49.41 $ | 1000 | CIR BRKR THRMMAG 8A 250VA... |
3120-F554-H7T1-W02Q-X3120-U0001M-16A | E-T-A | 49.41 $ | 1000 | CIR BRKR THRM 16A 250VAC ... |
3120-F351-P7T1-W14XR4-10A | E-T-A | 49.48 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W01D-15A-T | E-T-A | 49.9 $ | 1000 | CIRC BRKR THRM |
3120-F551-P7T1-W02Q-2.5A | E-T-A | 50.15 $ | 1000 | CIRC BRKR THRM |
3120-F35F-P7T1-SGRXG3-6A | E-T-A | 50.18 $ | 1000 | CIRC BRKR THRM |
3120-F35F-P7T1-SGRXG3-10A | E-T-A | 50.18 $ | 1000 | CIRC BRKR THRM |
3120-F35F-P7T1-SGRXG4-20A | E-T-A | 50.18 $ | 1000 | CIRC BRKR THRM |
3120-F321-H7T1-W12DY4-X3120-U0000M-15A | E-T-A | 50.23 $ | 1000 | CIR BRKR THRM 15A 250VAC ... |
3120-F321-H7T1-W14FR3-X3120-U0001M-10A | E-T-A | 50.23 $ | 1000 | CIR BRKR THRM 10A 250VAC ... |
3120-F321-H7T1-W14FR3-X3120-U0001M-16A | E-T-A | 50.23 $ | 1000 | CIR BRKR THRM 16A 250VAC ... |
3120-F321-H7T1-W19LG3-X3120-U0001M-20A | E-T-A | 50.23 $ | 1000 | CIR BRKR THRM 20A 250VAC ... |
3120-F321-H7T1-W19LG3-X3120-U0001M-10A | E-T-A | 50.24 $ | 1000 | CIR BRKR THRM 10A |
3120-F521-P7T1-W02D-3A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W02D-5A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F523-P7T1-W01D-3A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F523-P7T1-W01D-6A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F321-P7T1-W04K-20A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F523-P7T1-W01D-8A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W01K-15A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W01Q-20A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W02D-12A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W02D-15A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W02K-13A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F521-P7T1-W02Q-20A | E-T-A | 51.09 $ | 999 | CIRC BRKR THRM |
3120-F523-P7T1-W01D-12A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
3120-F523-P7T1-W01D-15A | E-T-A | 51.09 $ | 1000 | CIRC BRKR THRM |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A