Allicdata Part #: | 486-2958-ND |
Manufacturer Part#: |
4435.0002 |
Price: | $ 10.69 |
Product Category: | Circuit Protection |
Manufacturer: | Schurter Inc. |
Short Description: | CIR BRKR THRM 20A 240VAC 60VDC |
More Detail: | N/A |
DataSheet: | 4435.0002 Datasheet/PDF |
Quantity: | 94 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
1 +: | $ 9.72090 |
10 +: | $ 9.08712 |
20 +: | $ 8.45334 |
50 +: | $ 7.60802 |
100 +: | $ 7.18536 |
200 +: | $ 6.76267 |
500 +: | $ 6.34000 |
1000 +: | $ 5.91734 |
Series: | TA35 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal |
Current Rating: | 20A |
Voltage Rating - AC: | 240V |
Voltage Rating - DC: | 60V |
Number of Poles: | 2 |
Actuator Type: | Rocker |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are one of the most important devices for a safe and reliable power system and are essential components of power distribution systems. They are designed to provide protection against fault currents, overvoltage and overloads. The 4435.0002 circuit breaker is a type of circuit breaker that is commonly used in power distribution systems, and is important to understand its application fields and working principles.
Application Field of 4435.0002 Circuit Breaker
The 4435.0002 circuit breaker is well-suited for various types of applications, including commercial, industrial and residential use. It is particularly suitable for applications in homes and commercial buildings, such as apartment buildings, office buildings, shopping centers and hotels. It is also ideal for use in industrial applications such as heavy industry, power plants, and manufacturing facilities.
This type of circuit breaker can be used for short circuit protection, phase and ground overvoltage protection, phase and ground overcurrent protection, and phase and ground overload protection. It can be used for both AC and DC power systems, as well as a variety of voltages and frequencies, including 120V, 240V, 480V, and 600V systems.
The 4435.0002 circuit breaker is designed for easy installation, and can be wired to the load without the need for additional equipment or tools. It is simple to configure and is available in a wide variety of configurations, making it easy to find the right model for the application. It is also easy to maintain, with low maintenance requirements and an excellent degree of reliability.
Working Principle of 4435.0002 Circuit Breaker
The 4435.0002 circuit breaker works by using an electromagnet and a contact system to control the flow of current. The electromagnet is triggered when the system detects an overload or short circuit. When the electromagnet is triggered, a contact system, commonly known as an arc controller, opens the circuit breaker, interrupting the flow of current and protecting the system from damage.
The contact system consist of two metal contacts, a moving contact and a stationary contact. When an overload or short circuit is detected, the electromagnet is tripped and the two contacts are opened. This interrupts the flow of current and automatically shuts off the circuit breaker. The current can then be reset manually by pressing a reset button, restoring power to the circuit.
The 4435.0002 circuit breaker also contains a sensing device, which is used to detect the amount of current flowing in the system. When the system detects an overload or short circuit, the sensing device will trigger the electromagnet and open the circuit breaker. The sensing device also helps ensure that the circuit breaker trips correctly and does not trip unnecessarily.
The 4435.0002 circuit breaker is designed to provide reliable protection for the power system. It is safe, reliable, and easy to maintain, making it ideal for use in residential, commercial, and industrial applications. By understanding its application field and working principle, one can be assured that the power system is being protected and will be reliable and safe.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
142-4435-006 | Cinch Connec... | 7.13 $ | 1000 | CONN RPSMA PLUG STR 50OHM... |
142-4435-001 | Cinch Connec... | 8.01 $ | 1000 | CONN RPSMA PLUG STR 50OHM... |
142-4435-101 | Cinch Connec... | 8.32 $ | 1000 | CONN RPSMA PLUG R/A 50OHM... |
4435.0052 | Schurter Inc... | 0.87 $ | 495 | COVER AND COLLAR 1POLE IP... |
4435.0053 | Schurter Inc... | 0.92 $ | 175 | COVER AND COLLAR 2POLE IP... |
4435.0571 | Schurter Inc... | 6.8 $ | 0 | CIR BRKR THRM 3A 240VAC 3... |
4435.0253 | Schurter Inc... | 6.8 $ | 77 | CIR BRKR THRM 5A 240VAC 3... |
4435.0256 | Schurter Inc... | 6.8 $ | 72 | CIR BRKR THRM 20A 240VAC ... |
4435.0001 | Schurter Inc... | 6.8 $ | 58 | CIR BRKR THRM 20A 240VAC ... |
4435.0254 | Schurter Inc... | 6.8 $ | 50 | CIR BRKR THRM 10A 240VAC ... |
4435.0056 | Schurter Inc... | 6.8 $ | 40 | CIR BRKR THRM 10A 240VAC ... |
4435.0565 | Schurter Inc... | 6.8 $ | 27 | CIR BRKR THRM 6A 240VAC 3... |
4435.0019 | Schurter Inc... | 6.8 $ | 21 | CIR BRKR THRM 3A 240VAC 3... |
4435.0576 | Schurter Inc... | 7.74 $ | 80 | CIR BRKR THRM 1A 240VAC 3... |
4435.0577 | Schurter Inc... | 7.74 $ | 67 | CIR BRKR THRM 800MA 240VA... |
4435.0572 | Schurter Inc... | 7.74 $ | 50 | CIR BRKR THRM 2.5A 240VAC... |
4435.0573 | Schurter Inc... | 7.74 $ | 38 | CIR BRKR THRM 2A 240VAC 3... |
4435.0582 | Schurter Inc... | 7.74 $ | 30 | CIR BRKR THRM 100MA 240VA... |
4435.0002 | Schurter Inc... | 10.69 $ | 94 | CIR BRKR THRM 20A 240VAC ... |
4435.0042 | Schurter Inc... | 10.69 $ | 24 | CIR BRKR THRM 6A 240VAC 6... |
4435.004 | Schurter Inc... | 12.17 $ | 43 | CIR BRKR THRM 7A 240VAC 6... |
4435.0574 | Schurter Inc... | 7.74 $ | 42 | CIR BRKR THRM 1.5A 240VAC... |
4435.063 | Schurter Inc... | 10.55 $ | 40 | CIR BRKR THRM 10A 240VAC ... |
4435.0321 | Schurter Inc... | 12.17 $ | 49 | CIR BRKR THRM 20A 240VAC ... |
4435.0037 | Schurter Inc... | 6.8 $ | 18 | CIR BRKR THRM 15A 240VAC ... |
4435.0029 | Schurter Inc... | 7.74 $ | 1000 | CIR BRKR THRM 2A 240VAC 3... |
4435.0283 | Schurter Inc... | 10.69 $ | 1000 | CIR BRKR THRM 3A 240VAC 6... |
4435.0036 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 7A 240VAC 3... |
4435.0174 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4435.0201 | Schurter Inc... | 6.8 $ | 500 | CIR BRKR THRM 3A 240VAC 3... |
4435.0204 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 5A 240VAC 3... |
4435.0206 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 8A 240VAC 3... |
4435.0207 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4435.0209 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 16A 240VAC ... |
4435.021 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 20A 240VAC ... |
4435.0241 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4435.0297 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 7A 240VAC 3... |
4435.03 | Schurter Inc... | 6.8 $ | 1000 | CIR BRKR THRM 16A 240VAC ... |
4435.0196 | Schurter Inc... | 7.74 $ | 1000 | CIR BRKR THRM 500MA 240VA... |
4435.02 | Schurter Inc... | 7.74 $ | 1000 | CIR BRKR THRM 2.5A 240VAC... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A