Allicdata Part #: | 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A-ND |
Manufacturer Part#: |
8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A |
Price: | $ 156.11 |
Product Category: | Circuit Protection |
Manufacturer: | E-T-A |
Short Description: | CIR BRKR THRM 30A |
More Detail: | N/A |
DataSheet: | 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 141.92000 |
Series: | 8345 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 30A |
Voltage Rating - AC: | 277V |
Voltage Rating - DC: | 80V |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are electrical devices that are used to maintain a safe level of electrical system operation in industrial and commercial facilities. When the electrical system experiences a fault or overload, the circuit breaker will disconnect the circuit, preventing further damage. The model 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A circuit breaker is specifically designed to provide reliable protection against overcurrent, short circuits and other damaging fault conditions. It is equipped with a time delay feature to prevent nuisance tripping, and its built-in thermal and magnetic trip units provide the ultimate in performance and protection.
The 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A circuit breaker is designed for commercial and industrial applications. Its primary use is to protect circuits from motor overloads and from short-circuit conditions. In other words, when the current being used exceeds the amount of current the circuit breaker is rated for, the breaker will disconnect the circuit to prevent potential damage to the wiring or to other equipment. The breaker is also designed to detect when a short circuit occurs and disconnect the circuit to prevent further damage.
The operation of the 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A circuit breaker is based on two main principles. First, the thermal trip unit, which senses the temperature of the electrical current, is designed to disconnect the circuit when the current becomes too high. The second principle is the magnetic trip unit which is activated when the current is large enough to generate a magnetic field that is too strong for the circuit breaker to handle. The breaker will then detect this surge and open the circuit to protect against further electrical overloads and short-circuits.
The 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A circuit breaker also has a time delay feature which prevents nuisance tripping of the circuit. This means that if the breaker detects a small transient overload, it will allow the current to flow for a short period of time before tripping, thus avoiding the unnecessary tripping of the circuit. This feature gives the user the assurance that the circuit will remain operational during transient overloads without the need to manually reset the breaker.
In addition to the thermal and magnetic trip units, the 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A circuit breaker also has a manual trip feature. This feature allows the user to manually open the circuit in cases where the trip unit has failed for whatever reason. It is important to keep in mind, however, that using the manual trip feature may put the user in violation of safety regulations, so it is always best to have the breaker tested and serviced on a regular basis to avoid the possibility of overloading or short-circuiting.
The 8345-B02A-T3M2-DB1B1C-X8345-S01HW102M-30A circuit breaker is an advanced protection device that combines the reliability and dependability of a circuit breaker with the convenience and flexibility of a manual trip feature. Its built-in thermal and magnetic trip units provide reliable protection against overcurrent, short circuits, and other damaging fault conditions, while the time delay prevents nuisance tripping. It is designed to provide superior performance and protection in commercial and industrial applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
8345-B01A-T3M0-DB1B1B-20A | E-T-A | 67.22 $ | 1000 | CIR BRKR MAG-HYDR 20A 80V... |
8345-C01A-U3M1-DB1B1B-X8345-S01HW102M-80A | E-T-A | 81.44 $ | 1000 | CIR BRKR MAG-HYDR 80A 80V... |
8345-C01A-V3M2-DB1B1B-X8345-S01HW102M-80A | E-T-A | 81.44 $ | 1000 | CIR BRKR MAG-HYDR 80A 80V... |
8345-S00077-20A | E-T-A | 81.52 $ | 1000 | CIR BRKR MAG-HYDR 20A |
8345-F01A-V3T1-DB1B1B-100A | E-T-A | 81.59 $ | 1000 | CIR BRKR THRM 100A |
8345-E01Z-V3K1-DB1B2B-30A | E-T-A | 81.82 $ | 1000 | CIR BRKR MAG-HYDR 30A 80V... |
8345-B01A-T3M1-DB1B1B-50A-V | E-T-A | 82.28 $ | 1000 | CIR BRKR MAG-HYDR 50A 80V... |
8345-B01A-T3T1-DB1B1B-20A-V | E-T-A | 82.28 $ | 1000 | CIR BRKR MAG-HYDR 20A 80V... |
8345-B01A-T3T2-DB1B1B-20A-V | E-T-A | 82.28 $ | 1000 | CIR BRKR MAG-HYDR 20A 80V... |
8345-B01A-T3T2-DB1B1B-40A-V | E-T-A | 82.28 $ | 1000 | CIR BRKR MAG-HYDR 40A 80V... |
8345-B01A-T3M1-DB1B1B-20A-V | E-T-A | 82.28 $ | 1000 | CIR BRKR THRM 20A |
8345-C01A-U3K1-DB1B4B-X8345-S01HW102M-20A | E-T-A | 82.37 $ | 1000 | CIR BRKR MAG-HYDR 20A 80V... |
8345-C01A-U3K1-DB1B4B-X8345-S01HW102M-35A | E-T-A | 82.37 $ | 1000 | CIR BRKR MAG-HYDR 35A 80V... |
8345-C01A-U3K1-DB1B4B-X8345-S01HW102M-60A | E-T-A | 82.37 $ | 1000 | CIR BRKR MAG-HYDR 60A 80V... |
8345-E01Z-V3K1-DB1B2B-60A | E-T-A | 82.68 $ | 1000 | CIR BRKR MAG-HYDR 60A 80V... |
8345-B01A-V3M1-DB1B1B-100A-V | E-T-A | 84.2 $ | 1000 | CIR BRKR MAG-HYDR 100A 80... |
8345-B01A-V3T1-DB1B1B-100A-V | E-T-A | 84.2 $ | 1000 | CIR BRKR MAG-HYDR 100A 80... |
8345-C01A-R0M0-DB1A1B-125A | E-T-A | 86.28 $ | 1000 | CIR BRKR 125A 240VAC 80VD... |
8345-E01A-T3T2-DB1A1B-X8345-SO1HW102M-10A | E-T-A | 86.28 $ | 1000 | CIR BRKR MAG-HYDR 10A 80V... |
8345-F01A-R0M1-DB1B1B-125A | E-T-A | 86.28 $ | 1000 | CIR BRKR MAG-HYDR 125A 80... |
8345-C01A-U3M1-DB1B1B-X8345-S01HW102M-30A | E-T-A | 87.04 $ | 1000 | CIR BRKR MAG-HYDR 30A 80V... |
8345-C01A-U3M1-DB1B1B-X8345-S01HW102M-60A | E-T-A | 87.04 $ | 1000 | CIR BRKR MAG-HYDR 60A 80V... |
8345-B01A-V3T1-DB1B2B-5A-V | E-T-A | 88.09 $ | 1000 | CIRC BRKR HYDRAULIC MAGNE... |
8345-B01A-V3T1-DB1B2B-10A-V | E-T-A | 88.09 $ | 1000 | CIRC BRKR HYDRAULIC MAGNE... |
8345-B01A-V3T1-DB1B2B-15A-V | E-T-A | 88.09 $ | 1000 | CIRC BRKR HYDRAULIC MAGNE... |
8345-B01A-V3T1-DB1B2B-40A-V | E-T-A | 88.09 $ | 1000 | CIRC BRKR HYDRAULIC MAGNE... |
8345-F01A-V3K1-DB1B1B-X8345-S01HW102M-100A | E-T-A | 88.19 $ | 1000 | CIR BRKR MAG-HYDR 100A 80... |
8345-C01A-U3M0-DB1A1B-125A | E-T-A | 89.05 $ | 1000 | CIR BRKR 125A 240VAC 80VD... |
8345-B01A-V3M1-DB1A1B-125A | E-T-A | 89.05 $ | 1000 | CIR BRKR MAG-HYDR 125A 80... |
8345-C01A-U3M1-DB1A1B-125A | E-T-A | 89.05 $ | 1000 | CIR BRKR MAG-HYDR 125A 80... |
8345-C11A-V0K1-DB1B1B-125A | E-T-A | 89.05 $ | 1000 | CIR BRKR MAG-HYDR 125A 80... |
8345-B01A-V3T1-DB2B2B-125A | E-T-A | 89.96 $ | 1000 | CIR BRKR MAG-HYDR 125A 80... |
8345-B01A-V3M1-DB1B1B-125A | E-T-A | 89.96 $ | 1000 | CR BKR MAGHYDR 125A 480VA... |
8345-B01A-V3T1-DB1B2B-100A-V | E-T-A | 90.62 $ | 1000 | CIRC BRKR HYDRAULIC MAGNE... |
8345-C01A-U3M1-DB1A1A-20A | E-T-A | 92.18 $ | 1000 | CIR BRKR MAG-HYDR 20A LEV... |
8345-C01A-U3M1-DB1A1A-2A | E-T-A | 92.18 $ | 1000 | CIR BRKR MAG-HYDR 2A LEVE... |
8345-F21A-V3M2-DB1B1B-20A-V | E-T-A | 92.74 $ | 1000 | CIRC BRKR HYDRAULIC MAGNE... |
8345-F01A-U0T1-282013-125A | E-T-A | 92.86 $ | 1000 | CIR BRKR MAG-HYDR 125A 80... |
8345-F01Z-R0M1-DB1B1B-125A | E-T-A | 92.86 $ | 1000 | CIR BRKR THRM 125A |
8345-F01Z-R0M1-DB1B2B-125A | E-T-A | 92.86 $ | 1000 | CIR BRKR THRM 125A |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A