Allicdata Part #: | 283-2320-ND |
Manufacturer Part#: |
BK/ATC-20 |
Price: | $ 0.54 |
Product Category: | Circuit Protection |
Manufacturer: | Eaton |
Short Description: | FUSE AUTOMOTIVE 20A 32VDC BLADE |
More Detail: | N/A |
DataSheet: | BK/ATC-20 Datasheet/PDF |
Quantity: | 2375 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 0.48510 |
5 +: | $ 0.47124 |
10 +: | $ 0.45675 |
50 +: | $ 0.38405 |
100 +: | $ 0.31878 |
250 +: | $ 0.28980 |
500 +: | $ 0.24633 |
1000 +: | $ 0.21735 |
5000 +: | $ 0.19562 |
Series: | ATC® |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Fuse Type: | Automotive |
Current Rating: | 20A |
Voltage Rating - DC: | 32V |
Response Time: | Fast |
Package / Case: | Blade, ATO/ATC |
Mounting Type: | Holder |
Breaking Capacity @ Rated Voltage: | 1kA |
Approvals: | UL |
Operating Temperature: | -- |
Color: | Yellow |
Size / Dimension: | 0.760" L x 0.207" W x 0.492" H (19.30mm x 5.25mm x 12.50mm) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses are electrical protection devices designed and manufactured to limit or protect the system or components from over-current, over-voltage, reverse flow of electric current, or total electrical or power supply failure. BK/ATC-20 fuses are classified as low-voltage fuses and are commonly used for protection in residential, commercial, and light industrial applications. In this article, we will discuss what applications these fuses are used for and the working principle behind them.
Applications of BK/ATC-20 Fuses
BK/ATC-20 fuses are primarily used for residential, commercial, and light industrial applications that require low voltage protection, such as in lighting circuits, refrigeration systems, and HVAC systems. They are also used in motors, pumps, and other motor-driven loads. The fuse can also be used in circuits where the current may fluctuate or drop suddenly. They are designed to protect against overloads, short circuits, and ground faults.
Low voltage applications are applications that require fuses with working voltage of no more than 600V. These fuses are designed for 400V system applications and have a current rating of 20A. They come in two sizes; standard size and miniature size. The type BK/ATC-20 is a dual-element fuse with a time-delay feature so that it can handle temporary overloads. The dual-element feature also provides a greater amount of current protection than is available with a single-element fuse.
Working Principle of BK/ATC-20 Fuses
The BK/ATC-20 fuse has two elements; a glass tube and a metal ring. The glass tube is filled with a fusible alloy material that melts when the current through the fuse is too high. This melting of the fusible element interrupts the flow of current and causes the fuse to blow. The metal ring is located around the outside of the tube and it acts as a safety device. If the fuse does blow, the metal ring will catch any pieces of the melted fusible element, thus preventing them from escaping and causing a fire.
The BK/ATC-20 fuse has a dual-element design. This means that it has two components; a thermal element and an electrical element. The thermal element responds to an increase in current and begins to heat up. As the temperature increases, the electrical element starts to open up. Once the electrical element opens, it interrupts the flow of current and the fuse blows. This time-delay feature helps to protect the circuit from transient overloads.
The BK/ATC-20 fuse is also designed to be reset after it has blown. To reset it, the user needs to remove the old fuse and replace it with a new one. Resetting the fuse after it has blown ensures that the circuit will continue to be protected from overloads and short circuits. This resetting feature also helps to protect the system from potentially dangerous and costly power outages caused by a blown fuse.
Conclusion
In conclusion, BK/ATC-20 fuses are designed for low voltage protection in residential, commercial, and light industrial applications. They are designed to protect against overloads, short circuits, and ground faults. The dual-element design with time-delay feature provides increased protection against sudden transient overloads. The fuse can also be easily reset after it has blown. Therefore, the BK/ATC-20 fuse is ideal for a variety of low voltage applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
BKAC2-313-30002-FO | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAE2-234M-30010-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 234PO... |
BKAE2-31330001F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAE2-313-30004-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAE2-313-30009-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAD3-62630001F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 626PO... |
BKAD3-626-30011-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 626PO... |
BKAE2-40030001F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 400PO... |
BKAE2-400-30002-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 400PO... |
BKAE2-155M-30001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 155PO... |
BKAE2-30030001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 300PO... |
BKAD3-80030001F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 800PO... |
BKAD3-800-30022-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 800PO... |
BKAD2-Q174-40001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL RCPT 174PO... |
BKAE2-234M-30001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 234PO... |
BKAE2-234M-300 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 234PO... |
BKAD2-25330001F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 253PO... |
BKAD2-155-31201-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 155PO... |
BKAE2-313-30009 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAE2-31330001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAE2-313-30096 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAE2-313-30030 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAE2-313-30010 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 313PO... |
BKAD16740072 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 125PO... |
BKAD2-071-40001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL RCPT 71POS... |
BKAD2-155-30000 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 155PO... |
BKAD2-155-31201 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 155PO... |
BKAD3-600-30001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 600PO... |
BKAE2-40030001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 400PO... |
BKAE2-155M-40001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL RCPT 155PO... |
BKAD2-25330001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 253PO... |
BKAD3-62630001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 626PO... |
BKAD3-626-30015 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 626PO... |
BKAD3-A71330001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 713PO... |
BKAD3-71330001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 713PO... |
BKAD3-80030001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 800PO... |
BKAD3-800300 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 800PO... |
BKAD3-800-30022 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL PLUG 800PO... |
BKAD2-155-40001-F0 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL RCPT 155PO... |
BKAD2-234-40001 | ITT Cannon, ... | 0.0 $ | 1000 | RACK AND PANEL RCPT 234PO... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL