BK/GLX-1/2 Allicdata Electronics
Allicdata Part #:

BK/GLX-1/2-ND

Manufacturer Part#:

BK/GLX-1/2

Price: $ 14.59
Product Category:

Circuit Protection

Manufacturer: Eaton
Short Description: FUSE BRD MNT 500MA 125VAC RADIAL
More Detail: N/A
DataSheet: BK/GLX-1/2 datasheetBK/GLX-1/2 Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Contains lead / RoHS non-compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
100 +: $ 13.25840
Stock 1000Can Ship Immediately
$ 14.59
Specifications
Series: GLX
Packaging: Bulk 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Fuse Type: Board Mount (Cartridge Style Excluded)
Current Rating: 500mA
Voltage Rating - AC: 125V
Response Time: Fast
Package / Case: Radial Bend Cylinder
Mounting Type: Through Hole
Breaking Capacity @ Rated Voltage: 50A
Approvals: --
Operating Temperature: --
Color: --
Size / Dimension: 0.146" Dia x 0.299" L (3.70mm x 7.60mm)
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

BK/GLX-1/2 Application Field and Working Principle

Fuses are simple but highly effective forms of overcurrent protection. Suitable for a wide variety of electrical installation applications, fuses provide effective overload protection and isolation, by using two alloys to perform an action when a fault occurs. As a result, a fuse prevents a current flow from one conductor to another by opening the circuit, and thus provides a significant safety benefit.

For high voltage applications, the BK/GLX-1/2 range of fuses provides a reliable means of protection. This type of fuse operates in a current-limiting mode and has a rated breaking capacity of at least 20 kA. It can also withstand an impulse withstand voltage of at least 80 kV.

The BK/GLX-1/2 range of fuses is designed to be used as a power system protection device in a variety of switchgear system configurations. These include direct connected applications, three-pole fuse switch devices, and busbar current-limiting fuses, depending on the application requirements. As such, they are suitable for use in the protection of motors, transformers, rectifiers, capacitors, and other connected electrical equipment.

In operation, the BK/GLX-1/2 fuse uses two alloys to provide overload protection and isolation. The fuse is made of two contact pieces connected with a conductor. The two contact pieces are usually made from different metals with different melting points and electrical conductivities. When an overcurrent is detected, the lower melting point metal quickly melts and opens the circuit, thereby preventing any further current flow. This quick action prevents damage to the electrical equipment and provides a safe environment for users.

The BK/GLX-1/2 range of fuses also includes a range of fuses specifically designed for photovoltaic systems. These include the BK/GLX XI2000/M/I/X, which provides a four pole configuration suitable for use in photovoltaic systems. This type of fuse allows for a deferred operating time, which provides additional protection for the photovoltaic system and ensures that overcurrents are detected before damage can occur.

Overall, the BK/GLX-1/2 range provides a reliable, safe, and cost-effective solution for many overcurrent protection applications. Their applications and benefits can provide an extra layer of protection for electrical installations of any size.

The specific data is subject to PDF, and the above content is for reference

Latest Products
3404.0011.11

FUSE BRD MNT 1.6A 125VAC/VDC SMD

3404.0011.11 Allicdata Electronics
2060.0048.11

FUSE BOARD MNT 3.15A 125VAC/VDC

2060.0048.11 Allicdata Electronics
2060.0043.11

FUSE BOARD MNT 350MA 125VAC/VDC

2060.0043.11 Allicdata Electronics
2060.0013.11

FUSE BRD MNT 2.5A 125VAC/VDC SMD

2060.0013.11 Allicdata Electronics
2060.0011.11

FUSE BRD MNT 1.6A 125VAC/VDC SMD

2060.0011.11 Allicdata Electronics
2040.0715

FUSE BOARD MNT 1A 250VAC RADIAL

2040.0715 Allicdata Electronics