BMI-S-107 Allicdata Electronics

BMI-S-107 RF/IF and RFID

Allicdata Part #:

903-1012-2-ND

Manufacturer Part#:

BMI-S-107

Price: $ 2.22
Product Category:

RF/IF and RFID

Manufacturer: Laird Technologies EMI
Short Description: BOARD SHIELD 1.747X1.747" 1PIECE
More Detail: RF Shield Shield, 1-Piece 1.747" (44.37mm) X 1.747...
DataSheet: BMI-S-107 datasheetBMI-S-107 Datasheet/PDF
Quantity: 4680
120 +: $ 2.01695
360 +: $ 1.82016
600 +: $ 1.63323
840 +: $ 1.47580
1200 +: $ 1.37742
3000 +: $ 1.30854
Stock 4680Can Ship Immediately
$ 2.22
Specifications
Series: --
Packaging: Tape & Reel (TR) 
Part Status: Active
Type: Shield, 1-Piece
Height - Overall: 0.384" (9.75mm)
Length - Overall: 1.747" (44.37mm)
Width - Overall: 1.747" (44.37mm)
Ventilation: Vent Holes in Pattern
Mounting Type: Solder
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

IntroductionThe BMI-S-107 is a RF shield designed especially for applications in the medical, military and telecommunications fields. It is used to contain high frequency electromagnetic radiation from the equipment that needs to achieve a secure interference-free environment. The BMI-S-107 comes in two standard sizes, 39x40mm and 72x72mm. It consists of a housing, an absorptive material, a metallic shielding mesh and an optional wire mesh. The design of the shield is optimized for applications in which there is an intentional radiation source. Working PrincipleThe BMI-S-107 RF shield uses its absorptive material and vast array of sizes to absorb any unwanted electromagnetic radiation. The absorbent material works by trapping and absorbing the electromagnetic waves that travel in the environment. The absorbent material also helps to reduce reflections off any metallic surfaces.In addition to the absorbent material, the shield also contains a metallic shielding mesh. This mesh is designed to protect the equipment from any external radiation sources. This shielding mesh is made up of an array of wires that form an electrical connection between the absorptive material and the components inside the shield. This connection serves as a barrier that stops radiation from entering the shielded environment.The last component of the BMI-S-107 is an optional wire mesh. This mesh is used to stop the emitted radiation from entering and exiting the shield. The mesh works by creating a Faraday cage effect, which is designed to block any radiation that is trying to enter or exit the shielded environment. The shielding mesh also adds additional protection against short circuit currents. Application FieldsThe BMI-S-107 is designed for use in a variety of applications including communications, medical, military, telecommunications, and other sensitive applications. The communications industry uses the BMI-S-107 to shield their systems from external interference. The shielding helps to protect communication lines from domestic, commercial and military sources of interference. It also helps to protect against system crashes caused by external interference. The medical industry also uses the BMI-S-107 to shield against external interference. The shield helps to protect medical instruments from external interference which can cause inaccurate readings. The shielding mesh also helps to protect sensitive electrical components from short circuit currents.The military also uses this shield to protect their sensitive electronics from any external interference. The shield helps to protect electronic systems from outside interference which can cause system crashes. The shielding mesh also helps to protect the system from short circuit currents that can damage sensitive components.The telecommunications industry uses the BMI-S-107 to contain high frequency electromagnetic radiation from the equipment they use. This helps to create a secure, interference-free environment for their devices.ConclusionThe BMI-S-107 is a RF shield designed especially for applications in the medical, military and telecommunications fields. It consists of a housing, an absorptive material, a metallic shielding mesh and an optional wire mesh. The absorbent material works to trap and absorb the electromagnetic waves that travel in the environment. In addition, the shield uses its shielding mesh to block any external radiation sources from entering and exiting the shielded environment. The shield is used to create a secure, interference-free environment for sensitive applications such as communications, medical, military and telecommunications.

The specific data is subject to PDF, and the above content is for reference

Latest Products
48-CBSA-1.25X5.75X0.4

48 SERIES CBS SHIELD ASSEMBLYRF Shield S...

48-CBSA-1.25X5.75X0.4 Allicdata Electronics
49L-CBSFNSV-0.75X1.75X0.5

49L-CBSFNSV-0.75X1.75X0.5--49L13RF Shiel...

49L-CBSFNSV-0.75X1.75X0.5 Allicdata Electronics
21M-CBSA-5.25X5.75X0.225

21M SERIES CBS SHIELD ASSEMBLY -RF Shiel...

21M-CBSA-5.25X5.75X0.225 Allicdata Electronics
42-CBSA-5.0X5.75X0.4

42 SERIES CBS SHIELD ASSEMBLYRF Shield S...

42-CBSA-5.0X5.75X0.4 Allicdata Electronics
55-CBSA-4.5X5.75X0.5

55 SERIES CBS SHIELD ASSEMBLY -RF Shield...

55-CBSA-4.5X5.75X0.5 Allicdata Electronics
29-CBSA-5.75X6.0X0.2

29 SERIES CBS SHIELD ASSEMBLY -RF Shield...

29-CBSA-5.75X6.0X0.2 Allicdata Electronics