Allicdata Part #: | BP/MB-20-ND |
Manufacturer Part#: |
BP/MB-20 |
Price: | $ 22.94 |
Product Category: | Circuit Protection |
Manufacturer: | Eaton |
Short Description: | PLUG TYPE CIRCUIT BREAKER |
More Detail: | N/A |
DataSheet: | BP/MB-20 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
5 +: | $ 20.85300 |
Specifications
Series: | MB |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | -- |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 20A |
Voltage Rating - AC: | 125V |
Number of Poles: | 1 |
Actuator Type: | Push to Reset |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Holder |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit Breakers: BP/MB-20 Application Field and Working Principle
A circuit breaker is an important device that helps protect electrical systems from overcurrent and short circuit conditions. BP/MB-20 is one of the most recognizable circuit breakers that is widely used in the commercial, industrial, and residential applications. This article will focus on the application fields, structure, and working principle of BP/MB-20 circuit breakers.Application Field
BP/MB-20 is a UL 1077 listing Circuit Breaker and it is suitable for use in AC power systems. This circuit breaker is UL Recognized and has been tested with UL standard 489. It is rated for 600 Volts with a maximum of 150 Amps. It is well-suited for use in industrial, commercial, and residential applications.Additionally, the BP/MB-20 circuit breaker is UL Classified for arc fault current interruption. When used in combination with a CT this circuit breaker can be used to detect an arc fault and initiate rapid detection of arc faults. This makes it ideal for use in AFCI applications for residential and commercial building as it can help to reduce the fire hazard that arc faults can cause.Structure
The BP/MB-20 circuit breaker is composed of a molded case and trip unit. The molded case is made from a high temperature UL 94V-0 flame retardant thermoplastic material and it is designed to withstand temperatures up to 130°C. The trip unit is a two-piece assembly that is composed of a vacuum bottle and bimetallic elements. The vacuum bottle is a sealed unit that contains a pressurized mixture of inert gases that serves to trip the circuit breaker in the event of an overcurrent or short circuit condition.Working Principle
The BP/MB-20 circuit breaker works by utilizing the bimetallic elements and the vacuum bottle. The bimetallic elements are two pieces of metal that are joined together that expand and contract with changes in temperature. When current passes through the bimetallic elements, they generate heat and begin to expand. As the temperature continues to increase, the bimetallic elements expand, and the pressure inside the vacuum bottle begins to increase. When a preset threshold is reached, the pressure inside the bottle forces a plunger to push the circuit breaker contacts into the open position, thus interrupting the current flow. The BP/MB-20 circuit breaker is designed to respond quickly to overcurrent and short circuit conditions. The circuit breaker will begin tripping at a current of 2.5 times the rated current of the circuit breaker; this allows the circuit breaker to respond quickly and protect the system from any further damage. The BP/MB-20 circuit breaker also has a thermal-magnetic trip unit, which allows for remote resetting of the trip unit in the event of an overload.Conclusion
The BP/MB-20 circuit breaker provides exceptional protection from overcurrent, short circuit, and arc fault conditions. It is UL listed and rated for 600 Volts with a maximum of 150 Amps, and it is suitable for use in commercial, industrial, and residential applications. The circuit breaker utilizes a bimetallic element and vacuum bottle to rapidly detect and interrupt current flow in the event of an overcurrent or short circuit condition. Additionally, the thermal-magnetic trip unit allows for quick resetting of the trip unit, making BP/MB-20 an ideal choice for protecting electrical systems.The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "BP/M" Included word is 40
Part Number | Manufacturer | Price | Quantity | Description |
---|
BPM1234SJ | Tamura | 10.3 $ | 89 | DC/DC CONVERTER 12VIsolat... |
BPM15-050-Q48-C | Murata Power... | 20.79 $ | 74 | DC/DC CONVERTER +/-5V 15W... |
BPM15-150-Q12-C | Murata Power... | 20.79 $ | 65 | DC/DC CONVERTER +/-15V 15... |
BPM15-150-Q12P-C | Murata Power... | 21.04 $ | 100 | DC/DC CONVERTER +/-15V 15... |
BPM15-050-Q12-C | Murata Power... | 20.79 $ | 63 | DC/DC CONVERTER +/-5V 15W... |
BPM15-120-Q12-C | Murata Power... | 20.79 $ | 48 | DC/DC CONVERTER +/-12V 15... |
BPM15-120-Q48-C | Murata Power... | 20.79 $ | 81 | DC/DC CONVERTER +/-12V 15... |
BPM15-050-Q48P-C | Murata Power... | 21.04 $ | 96 | DC/DC CONVERTER +/-5V 15W... |
BPM15-120-Q48P-C | Murata Power... | 21.04 $ | 88 | DC/DC CONVERTER +/-12V 15... |
BPM15-150-Q48P-C | Murata Power... | 21.04 $ | 74 | DC/DC CONVERTER +/-15V 15... |
BPM15-120-Q12N-C | Murata Power... | 21.25 $ | 96 | DC/DC CONVERTER +/-12V 15... |
BPM15-050-Q12N-C | Murata Power... | 21.25 $ | 91 | DC/DC CONVERTER +/-5V 15W... |
BPM15-150-Q48N-C | Murata Power... | 21.25 $ | 83 | DC/DC CONVERTER +/-15V 15... |
BPM15-050-Q48N-C | Murata Power... | 21.25 $ | 66 | DC/DC CONVERTER +/-5V 15W... |
BPM15-120-Q48N-C | Murata Power... | 21.25 $ | 36 | DC/DC CONVERTER +/-12V 15... |
BPM2417SJ | Tamura | 7.55 $ | 431 | DC/DC CONVERTER 24VIsolat... |
BPM15-150-Q48-C | Murata Power... | 20.79 $ | 132 | DC/DC CONVERTER +/-15V 15... |
BPM15-120-Q12P-C | Murata Power... | 21.04 $ | 138 | DC/DC CONVERTER +/-12V 15... |
BPM15-050-Q12P-C | Murata Power... | 21.04 $ | 159 | DC/DC CONVERTER +/-5V 15W... |
BPM15-150-Q12N-C | Murata Power... | 21.25 $ | 135 | DC/DC CONVERTER +/-15V 15... |
BPMULTI | Tripp Lite | 0.0 $ | 1000 | CONN FOR BATT PACK DAISY ... |
A22NN-BPM-NWA-G101-NN | Omron Automa... | 10.45 $ | 1000 | SWITCH PUSH DPST-NO 10A 1... |
A22NZ-BPM-UOA | Omron Automa... | 2.74 $ | 1000 | ORANGE PLSTIC BEZEL, PROJ... |
BPM-2 | Essentra Com... | 0.4 $ | 9297 | FOOT CYLINDRICAL 0.394" D... |
BPM-1 | Essentra Com... | 0.16 $ | 1000 | FOOT CYLINDRICAL 0.394" D... |
BPM-3 | Essentra Com... | 0.2 $ | 1000 | FOOT CYLINDRICAL 0.394" D... |
BPM-22261 | Bud Industri... | 75.54 $ | 43 | BRACKET POLE MNT FOR NEMA... |
BPM-22260 | Bud Industri... | 53.02 $ | 94 | BRACKET POLE MNT FOR NEMA... |
BPM500YPV | Eaton | 61.69 $ | 1000 | VARISTOR 1KV 25KA MOD PLU... |
BPM320IEC | Eaton | 76.95 $ | 1000 | VARISTOR 230V 40KA MOD PL... |
BPM385IEC | Eaton | 76.95 $ | 1000 | VARISTOR 230V 40KA MOD PL... |
BPM750WE | Eaton | 76.95 $ | 1000 | VARISTOR 690V 25KA MOD PL... |
BPMA48D60LV | Eaton | 88.55 $ | 1000 | VARISTOR 25KA MODULE PLUG... |
BPM440IEC | Eaton | 92.33 $ | 1000 | VARISTOR 400V 40KA MOD PL... |
BPM600IEC | Eaton | 100.02 $ | 1000 | VARISTOR 480V 30KA MOD PL... |
BPM275UL | Eaton | 34.35 $ | 1000 | VARISTOR 120V 40KA MOD PL... |
BPMA275D350LV | Eaton | 40.47 $ | 1000 | VARISTOR 40KA MODULE PLUG... |
BPMA320D420LV | Eaton | 40.47 $ | 1000 | VARISTOR 40KA MODULE PLUG... |
BPMA385D500LV | Eaton | 40.47 $ | 1000 | VARISTOR 40KA MODULE PLUG... |
BPM300YPV | Eaton | 46.27 $ | 1000 | VARISTOR 600V 25KA MOD PL... |
Latest Products
UPG11-4038-10
CIRCUIT BREAKER MAG-HYDR LEVER
299-3-3283-14
CIRCUIT BREAKER MAG-HYDR LEVER
JLE-1-1REG4-52-3-B1-200-A...
CIR BRKR MAG-HYDR 200A 160VDC
IEGH666-1REC4-72-32.0-01-...
CIR BRKR MAG-HYDR
483-G641-K1M1-A1S0ZN-5A
CIRC BRKR THRM
IEG111-1-52-10.0-01-V
CIR BRKR MAG-HYDR LEVER 10A