Specifications
Series: --
Packaging: Bulk 
Part Status: Active
Coupler Type: Standard
Frequency: 2GHz ~ 18GHz
Coupling Factor: 6dB ± 1dB
Applications: --
Insertion Loss: 0.8dB
Power - Max: 50W
Isolation: --
Return Loss: --
Package / Case: N-Type In-Line Module
Supplier Device Package: --
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

CPL-5232-06-NNN-79 application field and working principle

The CPL-5232-06-NNN-79 is a type of RF directional coupler, which is mainly used to sample and measure signals in power amplifiers, power monitoring circuits, radio receivers, television transmission systems and digital communication systems. RF directional couplers typically consist of two or more transmission lines, but are usually not physically connected. Both transmission lines are connected to the same central ground connection, and the input signal is applied to the input port of the directional coupler. The signal will be divided into two components, one part will pass through the directional coupler and be emitted as output, while the other part is reflected back to the coupler.

This RF directional coupler CPL-5232-06-NNN-79 is a 3-port device that functions as an ideal travelling wave direction coupler. These directional couplers use a pair of narrow transmission lines coupled together by a large fraction of their line capacity. The transmission lines are connected to the two input ports which cause the travelling wave to move from the input port to the output port. The passing wave amplitude at the output port is a function of the coupling coefficient and the directivity of the coupler.

The directional coupler uses capacitive coupling instead of inductive coupling as other types of directional couplers. This means that the output port of the coupler is sensitive to both the forward travelling wave and the reflected wave, rather than just the forward wave with inductive coupling. This unique combination of capacitive and inductive coupling makes the device particularly suitable for applications like power monitoring circuits, radio receivers, and digital communications systems.

The main operating principle of CPL-5232-06-NNN-79 is lossless energy transfer. When the input signal is applied to the input port, a part of the energy will be reflected by the coupling configuration to the output port at the same amplitude as that of the input port. This energy transfer will occur for both the forward and reverse wave, thus the transmitted energy can be regarded as the same energy as that at the input port.

The CPL-5232-06-NNN-79 is typically used in applications where a high degree of accuracy is required, such as measuring gains in power amplifiers or monitoring the power level in digital communication systems. The coupler allows for accurate measurement of the signal at the output port without disturbing the signal at the input port. It provides high signal integrity and good linearity when measuring the output signals, and is suitable for applications where signals have high bandwidth or low signal to noise ratios.

The CPL-5232-06-NNN-79 provides many advantages over other designs of couplers, such as high directivity, higher insertion loss, low power dissipation, and good stability. Furthermore, the coupler also features excellent repeatability and very low intermodulation distortion. All these features make it an ideal choice for applications that need accurate and reliable measurements of signal power levels.

In conclusion, the CPL-5232-06-NNN-79 is an RF directional coupler that is used in applications that necessitate precise measurements of signals. It provides excellent repeatability and low intermodulation distortion, and is suitable for applications where signals have high bandwidths or low signal to noise ratios. The main operating principle of the CPL-5232-06-NNN-79 is lossless energy transfer; and the device has many advantages over other directional coupler designs such as high directivity, higher insertion loss, low power dissipation, and good stability.

The specific data is subject to PDF, and the above content is for reference

Latest Products
CPL-5226-06-NNN-79

COUPLER 6 DB 6-18GHZRF Directional Coupl...

CPL-5226-06-NNN-79 Allicdata Electronics
CPL-5232-20-SMA-79

COUPLER 20 DB 2-18GHZRF Directional Coup...

CPL-5232-20-SMA-79 Allicdata Electronics
1E1305-3

COUPLER HYBRID 1.2-1.85GHZRF Directional...

1E1305-3 Allicdata Electronics
XC1500A-20S

DIRECTIONAL COUPLERRF Directional Couple...

XC1500A-20S Allicdata Electronics
CP0805B1100CWTR

DIRECTIONAL COUPLER 1100MHZ 0805RF Direc...

CP0805B1100CWTR Allicdata Electronics
CP0603A2100FLTR

DIRECTIONAL COUPLER 2100MHZ 0603RF Direc...

CP0603A2100FLTR Allicdata Electronics