Allicdata Part #: | EAP-16-472-D-ND |
Manufacturer Part#: |
EAP-16-472-D |
Price: | $ 21.59 |
Product Category: | Filters |
Manufacturer: | Cosel USA, Inc. |
Short Description: | LINE FILTER 250VDC/VAC 16A DIN |
More Detail: | N/A |
DataSheet: | EAP-16-472-D Datasheet/PDF |
Quantity: | 1000 |
1 +: | $ 19.62450 |
Series: | EAP |
Part Status: | Active |
Filter Type: | Single Phase |
Configuration: | Single Stage |
Voltage - Rated DC: | 250V |
Voltage - Rated AC: | 250V |
Voltage - Rated AC (Phase to Ground/Neutral): | 250V |
Current: | 16A |
Frequency - Operating: | -- |
Applications: | General Purpose |
Approvals: | cURus, VDE |
Operating Temperature: | -40°C ~ 85°C |
Mounting Type: | DIN Rail |
Termination Style: | Terminal Block |
Inductance: | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
The EAP-16-472-D is a power line filter module used in different electronic applications. It is designed to protect and filter power lines from unwanted noise, helping to ensure the components connected to the power line are not affected by RF interference and are provided with the clean power they need to properly function. The filter module is available in both commercial and industrial grades.
The EAP-16-472-D power line filter module is designed to suppress differential-mode electromagnetic interference. The module operates using a filter architecture that is based on the use of common-mode and differential-mode chokes, along with bypass capacitors.
The common-mode choke is the first component of the filter architecture, and its purpose is to reduce the amount of common-mode currents flowing through the line. This is done by reducing the inductance of the common-mode current waves, which helps prevent interference from nearby devices. The differential-mode choke is used to reduce the amount of high-frequency noise on the line, and it works by inductively coupling the alternating current of the interference to ground. This helps reduce the amount of noise on the line and also helps reduce the voltage across the two terminals of the filter.
The bypass capacitors are then used to shunt any high-frequency interference away from the power line, further reducing the amount of noise on the line. The bypass capacitors are usually connected in series with one end connected to ground, and the other end connected to the power source. This helps reduce the AC voltage across the two terminals, and thus reducing the amount of noise on the line.
The EAP-16-472-D power line filter module can be used in various applications, such as industrial and commercial. In industrial applications, the filter module is used to reduce induced interference from nearby devices on electrical equipment, as well as to protect against overvoltage surges, and provide protection against transients. In commercial applications, the filter module is used to provide clean power to consumer electronics, providing protection against interference from nearby devices and noise from other sources.
The EAP-16-472-D power line filter module is a solid filter choice for applications that require reliable filtering of power lines and protection from unwanted noise. This module is designed to provide high levels of isolation and interference suppression, and provides users with reliable protection against electromagnetic interference and overvoltage surges.
The specific data is subject to PDF, and the above content is for reference
LINE FILTER 250VAC 20A CHASS MNT
LINE FILTER 125/250VAC 4A TH
LINE FILTER 500VAC 100A CHASSIS
LINE FILTER 480VAC 50A CHASS MNT
LINE FILTER 480/520VAC 36A CHASS
LINE FILTER 480VAC 65A CHASS MNT