Allicdata Part #: | ESX10-103-DC24V-10A-E-ND |
Manufacturer Part#: |
ESX10-103-DC24V-10A-E |
Price: | $ 50.94 |
Product Category: | Circuit Protection |
Manufacturer: | E-T-A |
Short Description: | CIRC BRKR THRM |
More Detail: | N/A |
DataSheet: | ESX10-103-DC24V-10A-E Datasheet/PDF |
Quantity: | 1000 |
1 +: | $ 46.30500 |
Series: | * |
Part Status: | Active |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are designed to ensure a certain level of safety to people, systems and machines. They are used to prevent electrical surges, shorts and overloads that can damage components and even cause death or injury. An ESX10-103-DC24V-10A-E is a common circuit breaker designed for industrial and commercial applications.
The ESX10-103-DC24V-10A-E circuit breaker is mainly used to protect circuits against short circuits, overloads, overvoltages and undervoltages. When one of these faults occurs, the breaker automatically triggers the circuit protection and cuts off the power supply. This ensures the safety of personnel and systems in the event of a fault.
The circuit breakers are operated by a set of integrated contacts. The contacts are often composed of a movable (paddle) and a stationary (trip) part. The paddle is held in place by a spring-loaded mechanism, which is activated when an overload or short circuit occurs. This causes the trip to push the paddle, forming an electrical gap and cutting off the power supply. The trip mechanism is designed to be fast enough to be effective in an emergency.
In addition to protection from power surges, the ESX10-103-DC24V-10A-E circuit breaker also provides protection from undervoltages. A surge protector is used to sense when the incoming voltage is too low and opens the circuit, preventing equipment damage due to voltage dropouts.
The ESX10-103-DC24V-10A-E circuit breaker is widely used in commercial and industrial settings to protect electrical systems from power surges, overloads, shorts and undervoltages. It is designed to provide reliable protection from faults and prevent costly damage to equipment and personnel. It is a small, reliable and easy to install device that should be an essential part of any electrical system.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
ESX108M035AK2AA | KEMET | 0.44 $ | 1633 | CAP ALUM 1000UF 20% 35V R... |
ESX108M050AM7AA | KEMET | 0.64 $ | 1588 | CAP ALUM 1000UF 20% 50V R... |
ESX10-TB-101-DC24V-10A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 10A ... |
ESX10-TB-101-DC24V-12A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 12A ... |
ESX10-TB-101-DC24V-1A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 1A 2... |
ESX10-TB-101-DC24V-2A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 2A 2... |
ESX10-TB-101-DC24V-3A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 3A 2... |
ESX10-TB-101-DC24V-4A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 4A 2... |
ESX10-TB-101-DC24V-6A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 6A 2... |
ESX10-TB-101-DC24V-8A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 8A 2... |
ESX10-TB-102-DC24V-10A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 10A ... |
ESX10-TB-102-DC24V-1A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 1A 2... |
ESX10-TB-102-DC24V-2A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 2A 2... |
ESX10-TB-102-DC24V-4A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 4A 2... |
ESX10-TB-102-DC24V-6A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 6A 2... |
ESX10-TB-102-DC24V-8A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 8A 2... |
ESX10-TB-124-DC24V-10A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 10A ... |
ESX10-TB-124-DC24V-12A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 12A ... |
ESX10-TB-124-DC24V-1A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 1A 2... |
ESX10-TB-124-DC24V-2A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 2A 2... |
ESX10-TB-124-DC24V-3A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 3A 2... |
ESX10-TB-124-DC24V-4A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 4A 2... |
ESX10-TB-124-DC24V-6A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 6A 2... |
ESX10-TB-124-DC24V-8A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 8A 2... |
ESX10-TB-127-DC24V-12A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 12A ... |
ESX10-TB-127-DC24V-1A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 1A 2... |
ESX10-TB-127-DC24V-2A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 2A 2... |
ESX10-TB-127-DC24V-3A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 3A 2... |
ESX10-TB-127-DC24V-4A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 4A 2... |
ESX10-TB-127-DC24V-6A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 6A 2... |
ESX10-TC-124-DC12V-10A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 10A ... |
ESX10-TC-124-DC12V-1A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 1A 1... |
ESX10-TC-124-DC12V-2A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 2A 1... |
ESX10-TC-124-DC12V-3A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 3A 1... |
ESX10-TC-124-DC12V-4A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 4A 1... |
ESX10-TC-124-DC12V-6A-E | E-T-A | 50.94 $ | 1000 | CIR BRKR SOLID STATE 6A 1... |
ESX10-103-DC24V-1A-E | E-T-A | 50.94 $ | 1000 | CIRC BRKR THRM |
ESX10-103-DC24V-2A-E | E-T-A | 50.94 $ | 1000 | CIRC BRKR THRM |
ESX10-103-DC24V-3A-E | E-T-A | 50.94 $ | 1000 | CIRC BRKR THRM |
ESX10-103-DC24V-4A-E | E-T-A | 50.94 $ | 1000 | CIRC BRKR THRM |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A