Allicdata Part #: | 317-1337-ND |
Manufacturer Part#: |
F20A160053600060 |
Price: | $ 2.52 |
Product Category: | Sensors, Transducers |
Manufacturer: | Cantherm |
Short Description: | THERM NC 160C LEAD FRAME 2SIP |
More Detail: | N/A |
DataSheet: | F20A160053600060 Datasheet/PDF |
Quantity: | 1000 |
200 +: | $ 2.29547 |
Series: | F20 |
Part Status: | Active |
Circuit: | SPST-NC |
Switching Temperature: | 320°F (160°C) |
Reset Temperature: | 266°F (130°C) |
Current Rating - AC: | 1.6A (250V) |
Current Rating - DC: | -- |
Tolerance: | ±9°F (±5°C) |
Switching Cycles: | 7K |
Termination Style: | Wire Leads - 4" (101.6mm) |
Mounting Type: | Through Hole |
Package / Case: | 2-SIP, Potted |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Temperature Sensors - Thermostats - Mechanical
The F20A160053600060 is a cost effective and reliable device used for temperature applications. It is a mechanical thermostat, which consists of an enclosed thermostat that contains a bimetal strip, bellows, and rivet. This thermostat is used for controlling temperatures of system components, such as motors, pumps, and heaters. It is also used for preventing the system from overheating or freezing.
The working principle of the F20A160053600060 can be understood by looking at its components. The bimetal strip is made up of two metal strips bonded at one end, which behaves like a spring. When temperature rises, the bimetal strip is forced to bend, thereby activating the rivet and opening up a sensor contact. This sensor contact then switches the system off or on depending on the setting of the thermostat.
The bellows are responsible for sensing a change in temperature when the bimetal strip is activated. This is done by causing a pressure change within the thermostat. When the bimetal strip is bent, it causes the bellows to expand or contract, thus causing a pressure change in the bellows and working as a switch.
The F20A160053600060 is designed for use in a variety of temperature sensing applications. It is suitable for tasks such as motor temperature controlling, pump motor temperature controlling, heater temperature controlling, and freezing/overheating detection. It can be used in various systems, and is ideal for commercial and industrial applications such as air conditioning units, refrigeration units, and HVAC systems.
The F20A160053600060 is a cost effective and reliable choice for temperature applications. It is also easy to install and use, and requires minimal maintenance. This thermostat can be used for a wide array of temperature applications, and is suitable for many commercial and industrial settings.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
P120K-F20AR100K | TT Electroni... | 0.22 $ | 1000 | POTENTIOMETEROhm Gang ... |
P120PK-F20AR2K | TT Electroni... | 0.22 $ | 1000 | POTENTIOMETEROhm Gang ... |
P140KH-F20AR10K | TT Electroni... | 0.34 $ | 1000 | POTENTIOMETEROhm Gang ... |
P140KH-F20AR50K | TT Electroni... | 0.34 $ | 1000 | POTENTIOMETEROhm Gang ... |
P140KH1-F20AR5K | TT Electroni... | 0.36 $ | 1000 | POTENTIOMETEROhm Gang ... |
P140KV1-F20AR50K | TT Electroni... | 0.36 $ | 1000 | POTENTIOMETEROhm Gang ... |
K2CU-F20A-C AC8-20A AC100 | Omron Automa... | 193.19 $ | 1000 | DETECT HEATER ELEMENT 100... |
K2CU-F20A-D AC110 | Omron Automa... | 193.19 $ | 1000 | DETECT HEATER ELEMENT 110... |
K2CU-F20A-E-AC200 | Omron Automa... | 193.19 $ | 1000 | DETECT HEATER ELEMENT 200... |
K2CU-F20A-F AC220 | Omron Automa... | 193.19 $ | 1000 | DETECT HEATER ELEMENT 220... |
K2CU-F20A-FGS | Omron Automa... | 193.19 $ | 1000 | DETECT HEATER ELEMENT 220... |
K2CU-F20A-DGS | Omron Automa... | 199.75 $ | 1000 | DETECT HEATER ELEMENT 110... |
K2CU-F20A-EGS | Omron Automa... | 199.75 $ | 1000 | DETECT HEATER ELEMENT 200... |
CA08COM-F20A48S-B-01-F0 | ITT Cannon, ... | 24.81 $ | 1000 | CONN PLUG HSNG FMALE 19PO... |
CA08COM-F20A48SXB-01-F0 | ITT Cannon, ... | 24.81 $ | 1000 | CONN PLUG HSNG FMALE 19PO... |
CA08COM-F20A48SYB-01-F0 | ITT Cannon, ... | 24.81 $ | 1000 | CONN PLUG HSNG FMALE 19PO... |
F20A160051ZA0060 | Cantherm | 4.64 $ | 111 | THERMOSTAT 160 DEG C NC 2... |
F20A12505ACFA06E | Cantherm | 4.1 $ | 85 | THERMOSTAT 125 DEG C NC 2... |
F20A105053600060 | Cantherm | 4.1 $ | 77 | THERMOSTAT 105 DEG C NC 2... |
F20A135051ZA0060 | Cantherm | 4.1 $ | 35 | THERMOSTAT 135 DEG C NC 2... |
F20A07505ACFA06E | Cantherm | 4.1 $ | 1000 | THERMOSTAT 75 DEG C NC 2S... |
F20A095053600060 | Cantherm | 4.1 $ | 1000 | THERM NC 95C LEAD FRAME 2... |
F20A14505ACFA06E | Cantherm | 2.23 $ | 1000 | THERMOSTAT 145 DEG C NC 2... |
F20A075051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 75 DEG C NC 2S... |
F20A080051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 80 DEG C NC 2S... |
F20A085051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 85 DEG C NC 2S... |
F20A090051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 90 DEG C NC 2S... |
F20A095051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 95 DEG C NC 2S... |
F20A100051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 100 DEG C NC 2... |
F20A105051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 105 DEG C NC 2... |
F20A110051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 110 DEG C NC 2... |
F20A115051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 115 DEG C NC 2... |
F20A120051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 120 DEG C NC 2... |
F20A125051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 125 DEG C NC 2... |
F20A130051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 130 DEG C NC 2... |
F20A140051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 140 DEG C NC 2... |
F20A145051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 145 DEG C NC 2... |
F20A150051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 150 DEG C NC 2... |
F20A155051ZA0060 | Cantherm | 2.23 $ | 1000 | THERMOSTAT 155 DEG C NC 2... |
F20A115053600060 | Cantherm | 2.23 $ | 1000 | THERM NC 115C LEAD FRAME ... |
MANUAL RESET THERMOSTAT
CERAMIC MANUAL RESET THERMOSTAT
MANUAL RESET THERMOSTAT
AUTO RESET THERMOSTAT
AUTO RESET THERMOSTAT
AUTO RESET THERMOSTAT