FNA-2-1/4 Allicdata Electronics

FNA-2-1/4 Circuit Protection

Allicdata Part #:

FNA-2-1/4-ND

Manufacturer Part#:

FNA-2-1/4

Price: $ 18.82
Product Category:

Circuit Protection

Manufacturer: Eaton
Short Description: FUSE CARTRIDGE 2.25A 250VAC CYL
More Detail: N/A
DataSheet: FNA-2-1/4 datasheetFNA-2-1/4 Datasheet/PDF
Quantity: 1000
Moisture Sensitivity Level (MSL): 1 (Unlimited)
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
10 +: $ 17.10950
Stock 1000Can Ship Immediately
$ 18.82
Specifications
Applications: Electrical, Industrial
Size / Dimension: 0.406" Dia x 1.500" L (10.31mm x 38.10mm)
Package / Case: Cylindrical, Alarm Indicating, 5AG, 10x38.1mm
Mounting Type: Holder
Breaking Capacity @ Rated Voltage: 200A
Operating Temperature: --
Approvals: CE, CSA, UL
Class: --
Features: Indicating
Series: FNA
Response Time: Slow
Voltage Rating - AC: 250V
Current Rating: 2.25A
Fuse Type: Cartridge
Moisture Sensitivity Level (MSL): --
Part Status: Active
Lead Free Status / RoHS Status: --
Packaging: Bulk 
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

The FNA-2-1/4 is a type of speciality fuse, and is an integral part of the electrical setup for many applications. It is designed to perform a specific protective function in a circuit, and it is important to understand what the various components and features of these fuses are in order to use them correctly. As such, this article looks to explain the application field and working principle of the FNA-2-1/4.

The FNA-2-1/4 is designed to protect against current overloading in a circuit. Generally, when an electric current is detected that is above the safety limit of the circuit, the FNA-2-1/4 will trip and open the circuit, interrupting electricity flow and preventing any further damage. This type of circuit protection is especially important in electrical systems that could potentially be exposed to high energy currents or voltage overloads. The FNA-2-1/4 can also act as an advantageous first line of defence against overcurrents, offering better circuit protection than circuit breakers and other form of overprotection devices can.

The FNA-2-1/4 has an AC current rating of 2 amperes and a DC current rating of 1/4 amperes. In addition, it is also rated IP20, which means that it is designed to be used in interior locations only. This fuse is particularly suitable for use in low-voltage automotive applications, as well as for other applications such as surveillance systems and similar components. Furthermore, with two blade terminals, it can easily be connected to two different circuits.

In terms of construction, the FNA-2-1/4 has a one-piece molded body made from a flame-resistant material. The terminals are made from copper, and the base cap is made from high-grade thermoplastic. The epoxy molded seal has a protective sleeve with no bypass device, no arcing, and no delayed action. The fuse can handle up to 125°C of continuous operating temperature.

In terms of its working principle, the FNA-2-1/4 works by utilizing the Joule effect. When electric current passes through a conductor such as a wire, it creates heat at the point of contact. This is known as Joule heating, and as the current starts to rise, the temperature at the point of contact increases until it reaches the melting point of the conductor. When this point is reached, the fuse trips and the circuit is interrupted.

The FNA-2-1/4 is also designed with a calibrated release time, which is the time it takes for the fuse to open the circuit when an overcurrent is detected. This calibration is done by adjusting the shape of the arc during the manufacturing process, and is an important factor in determining the fuse’s efficiency as a protective device. The fuse should also be equipped with a short-circuit protection limiter to ensure that any short-circuits are prevented from causing damage to the circuit.

Overall, the FNA-2-1/4 is an important part of the electrical setup of many different applications, and its application field and working principle are essential to understand in order to use the fuse safely and effectively. As such, it is important to be familiar with what it is and how it works in order to utilize it correctly.

The specific data is subject to PDF, and the above content is for reference

Latest Products
CCMR009.T

FUSE CARTRIDGE 9A 600VAC/250VDC

CCMR009.T Allicdata Electronics
50NH00G-690

FUSE SQUARE 50A 690VAC RECT

50NH00G-690 Allicdata Electronics
KLPC2100X

FUSE CRTRDGE 2.1KA 600VAC/480VDC

KLPC2100X Allicdata Electronics
KLPC1400X

FUSE CRTRDGE 1.4KA 600VAC/480VDC

KLPC1400X Allicdata Electronics
150E1C5.5W

FUSE CARTRIDGE 150A 5.5KVAC

150E1C5.5W Allicdata Electronics
10E1CL15.5

FUSE CARTRIDGE 10A 15.5KVAC CYL

10E1CL15.5 Allicdata Electronics