$ 15.79
Specifications
Frequency: DC ~ 50kHz
Package / Case: Ring Opening 0.630" Dia, 4 Leads
Mounting Type: --
Polarization: Bidirectional
Operating Temperature: -40°C ~ 80°C
Current - Supply (Max): 15mA
Response Time: 3µs
Voltage - Supply: ±12 V ~ 15 V
Accuracy: ±1%
Linearity: ±1%
Series: HTB
Sensitivity: --
Output: Ratiometric, Voltage
Number of Channels: 1
Current - Sensing: 200A
Sensor Type: Hall Effect, Open Loop
For Measuring: AC/DC
Part Status: Active
Packaging: Tray 
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Current transducers are devices that are used to measure the current in electrical circuits. The HTB 200-P current transducer is a typical example of such a device.

The HTB 200-P current transducer is designed to provide a highly accurate DC or AC current measurement. It has a range of up to 200A and can measure up to 200mA. The device also has an integrated shunt resistor of 0.1 ohms, which is used to provide the electrical resistance needed for current measurement. The device also has a built-in temperature sensing element, which is used to compensate for temperature changes that can affect current measurements.

The HTB 200-P current transducer works on the principle of Faraday\'s law, which states that a change in current through a conductor is directly proportional to the inductance of the conductor. This means that when a current passes through the transducer, the inductance of the conductor will change and consequently the output voltage will vary. This is how the transducer measures the current.

The HTB 200-P current transducer can be used in a wide range of applications. For example, it can be used in industrial processes to measure the flow of current, in automotive systems to measure the battery charge level, and in fuel cells to measure the current generated by the fuel cells. The device can also be used to monitor the power consumption of electrical equipment, as well as for safety and security purposes.

The HTB 200-P current transducer is designed to provide a reliable and accurate current measurement device. The device is easy to use and has a range of features that make it suitable for a wide range of applications. It can be used in industrial processes, automotive systems, and for security and safety purposes.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "HTB " Included word is 40
Part Number Manufacturer Price Quantity Description
BK/HTB-44I-R Eaton 2.3 $ 618 FUSE HLDR CART 250V 20A P...
BK/HTB-44M-R Eaton 2.7 $ 569 FUSE HLDR CART 250V 16A P...
HTB18-N4A2AB SICK, Inc. 79.27 $ 1000 SEN PHT NPN LO/DO M12 RED...
HTB18-P4A2BED02 SICK, Inc. 82.95 $ 1000 SEN PHT PNP LO/DO M12 RED...
HTB18-A4A2BE SICK, Inc. 82.95 $ 1000 SEN PHT PNP/NPN DO M12 RE...
BK/HTB-22I Eaton 4.17 $ 1000 FUSE HLDR CART 250V 20A P...
HTB-28I-R Eaton 5.55 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-32I Eaton 0.0 $ 1000 FUSE HLDR CART 250V 20A P...
HTB18-B1G2AB SICK, Inc. 79.27 $ 7 SEN PHT PNP/NPN 150MM LO ...
HTB18L-P4B5BB SICK, Inc. 156.01 $ 1000 SEN PHT PNP LO/DO M12 RED...
HTB-44I-R Eaton 4.92 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-92M Eaton 0.0 $ 1000 FUSE HLDR CART 250V 16A P...
HTB3-C-M Panduit Corp 47.54 $ 1000 TAPE BARRICADE CAUTION
HTB18L-B4A5BD02 SICK, Inc. 140.48 $ 1000 SEN PHT PNP/NPN LO M12
BK/HTB-88I-R Eaton 3.63 $ 600 FUSE HLDR CART 250V 20A P...
BK/HTB-28M-SP Eaton 4.56 $ 1000 FUSE HLDR CART 250V 16A P...
BK/HTB-88 Eaton 0.0 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-82M Eaton 0.0 $ 1000 FUSE HLDR CART 250V 16A P...
HTB-32I-R Eaton 4.92 $ 1000 FUSE HLDR CART 250V 20A P...
HTB18L-B4A5BAD04 SICK, Inc. 140.48 $ 5 SEN PHT PNP/NPN 30-100MM ...
HTB18-A1G2BB SICK, Inc. 82.95 $ 1000 SEN PHT PNP/NPN DO CBL RE...
HTB18-P1G2AF SICK, Inc. 83.87 $ 1000 SEN PHT PNP LO/DO CBL
BK/HTB-22 Eaton 2.65 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-34I Eaton 4.17 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-68M Eaton 0.0 $ 1000 FUSE HLDR CART 250V 16A P...
HTB18-P4A2BB SICK, Inc. 82.95 $ 15 SEN PHT PNP 5-150MM LO/DO...
HTB18L-N3A5AB SICK, Inc. 145.14 $ 1000 SEN PHT NPN LO/DO M8-4 RE...
BK/HTB-48M-R Eaton 3.21 $ 345 FUSE HLDR CART 250V 16A P...
BK/HTB-26I-SP Eaton 4.62 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-22-R Eaton 0.0 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-24-R Eaton 0.0 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-82I-R Eaton 5.29 $ 61 FUSE HLDR CART 250V 20A P...
HTB18-P3B2BB SICK, Inc. 92.17 $ 15 SEN PHT PNP 5-150MM LO/DO...
BK/HTB-32I-R Eaton 5.29 $ 296 FUSE HLDR CART 250V 20A P...
HTB 200-P LEM USA Inc. 15.79 $ 128 SENSOR CURRENT HALL 200A ...
BK/HTB-24I-R Eaton 2.07 $ 8032 FUSE HLDR CART 250V 20A P...
BK/HTB-48I-MN Eaton 4.36 $ 1000 FUSE HLDR CART 250V 20A P...
BK/HTB-66-R Eaton 0.0 $ 1000 FUSE HLDR CART 250V 20A P...
HTB-88M-R Eaton 5.55 $ 1000 FUSE HLDR CART 250V 16A P...
HTB18-B4A2BAD04 SICK, Inc. 73.74 $ 1000 SEN PHT PNP/NPN LO M12 RE...
Latest Products
CR4110S-40

SENSOR CURRENT XFMR 40A ACCurrent Sensor...

CR4110S-40 Allicdata Electronics
CR4410-5

SENSOR CURRENT XFMR 5A ACCurrent Sensor ...

CR4410-5 Allicdata Electronics
HO 15-NSM-0000

SENSOR CURRENT HALL 15A AC/DCCurrent Sen...

HO 15-NSM-0000 Allicdata Electronics
LESR 50-NP KIT

3 PIECE KIT SENSOR CURRENT HALLCurrent S...

LESR 50-NP KIT Allicdata Electronics
2904923

PACT RCP-4000A-1A-D190Current Sensor 100...

2904923 Allicdata Electronics
CR5210S-30

SENSOR CURRENT HALL 30A DCCurrent Sensor...

CR5210S-30 Allicdata Electronics