HY 50-P Sensors, Transducers |
|
Allicdata Part #: | 398-1106-ND |
Manufacturer Part#: |
HY 50-P |
Price: | $ 18.22 |
Product Category: | Sensors, Transducers |
Manufacturer: | LEM USA Inc. |
Short Description: | SENSOR CURRENT HALL 50A AC/DC |
More Detail: | Current Sensor 50A 1 Channel Hall Effect, Open Loo... |
DataSheet: | HY 50-P Datasheet/PDF |
Quantity: | 96 |
1 +: | $ 16.56270 |
5 +: | $ 15.81050 |
10 +: | $ 14.30410 |
25 +: | $ 13.17480 |
50 +: | $ 11.66920 |
100 +: | $ 11.29270 |
500 +: | $ 10.53990 |
Series: | HY |
Packaging: | Tray |
Part Status: | Active |
For Measuring: | AC/DC |
Sensor Type: | Hall Effect, Open Loop |
Current - Sensing: | 50A |
Number of Channels: | 1 |
Output: | Ratiometric, Voltage |
Sensitivity: | -- |
Frequency: | DC ~ 50kHz |
Linearity: | ±1% |
Accuracy: | ±1% |
Voltage - Supply: | ±15V |
Response Time: | 3µs |
Current - Supply (Max): | 10mA |
Operating Temperature: | -10°C ~ 80°C |
Polarization: | Bidirectional |
Mounting Type: | Through Hole |
Package / Case: | Module |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers are physical devices, usually electrical in nature, which allow current to be measured. The HY 50-P current transducer is no exception. This device measures current by using a transformer to convert current into a voltage signal.
This transducer is primarily used in the identification of short-circuits, irregular currents, and excessive current levels. The HV 50-P can detect current as low as 0.2 Hz up to 50 kHz. It is also compatible with power lines ranging from 48V to 600V, making it suitable for many applications.
The working principle of the HY 50-P is similar to that of other transformer-based transducers. When an alternating current flows through the secondary winding of the transformer, the transformer\'s input creates an alternating flux. This alternating flux produces an induced voltage, which is then transformed into a proportional voltage level by the main transformer. The voltage level is then amplified by a low-noise amplifier, so it can be accurately measured.
The HV 50-P is used in a variety of applications. It is typically used to identify and monitor short circuits, as well as to measure the amount of current flowing through a power line at any given time. Additionally, it has been used in the automotive and aerospace industries to monitor and mitigate the risks associated with high voltage load handling.
The HY 50-P is also useful in general power monitoring applications. It can be used to detect faults in a power line, as well as to detect power fluctuations and power surges, so corrective action can be taken to protect sensitive equipment.
In summary, the HY 50-P is a reliable current transducer that can be used for a variety of applications ranging from identifying short-circuits to monitoring power lines. Its transformer-based design makes it a reliable, accurate device that can detect current levels from 0.2 Hz up to 50 kHz. This makes it suitable for many different applications, including those in the automotive and aerospace industries.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HY500 | 3M | 16.6 $ | 1000 | 3M PELTOR COMFORT HEADBA |
HY505 | 3M | 44.83 $ | 1000 | 3M PELTOR HYGIENE KIT HY |
HY53 PTL | 3M | 126.64 $ | 1000 | EARMUFF HYGIENE KIT 20PC |
HY539SG-13 | Diodes Incor... | -- | 1000 | IC REGULATOR LINEAR |
HY538PG-B | Diodes Incor... | 0.0 $ | 1000 | IC REGULATOR LINEAR |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...
SENSOR CURRENT XFMR 5A ACCurrent Sensor ...
SENSOR CURRENT HALL 15A AC/DCCurrent Sen...
3 PIECE KIT SENSOR CURRENT HALLCurrent S...
PACT RCP-4000A-1A-D190Current Sensor 100...
SENSOR CURRENT HALL 30A DCCurrent Sensor...