JLE-2-1-63F-5-B4-130 Allicdata Electronics

JLE-2-1-63F-5-B4-130 Circuit Protection

Allicdata Part #:

JLE-2-1-63F-5-B4-130-ND

Manufacturer Part#:

JLE-2-1-63F-5-B4-130

Price: $ 503.17
Product Category:

Circuit Protection

Manufacturer: Sensata-Airpax
Short Description: CIR BRKR MAG-HYDR 130A 240VAC
More Detail: N/A
DataSheet: JLE-2-1-63F-5-B4-130 datasheetJLE-2-1-63F-5-B4-130 Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
3 +: $ 457.43200
Stock 1000Can Ship Immediately
$ 503.17
Specifications
Series: JLE
Part Status: Active
Lead Free Status / RoHS Status: --
Breaker Type: Magnetic (Hydraulic Delay)
Moisture Sensitivity Level (MSL): --
Current Rating: 130A
Voltage Rating - AC: 240V
Number of Poles: 2
Actuator Type: Lever
Illumination: --
Illumination Voltage (Nominal): --
Mounting Type: Panel Mount
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Circuit breakers are an integral part of any electrical circuit, as they provide security and allow for independent control of individual circuits. JLE-2-1-63F-5-B4-130 is a type of circuit breaker which offers a host of features that enable it to be used in a variety of applications. As such, it is important to understand its work principle and the applications it can be used in.

Applications

The JLE-2-1-63F-5-B4-130 circuit breaker is designed to act as a protection and control device for electrical systems. It can be used in a variety of applications, including residential and industrial buildings, high-end power distribution systems, and in hazardous areas where flammable liquids or gases may be present. Additionally, the unit can be used in places where there is a high risk of fire or explosion, such as in wet environments or in areas with high levels of dust. As its housing is made of insulating material, it can also be used in damp environments, as well as outdoors.

The JLE-2-1-63F-5-B4-130 is particularly useful for residential applications, where it can be used to protect circuits in power outlets, and for industrial applications, where it can be used to protect larger systems. It can also be used to protect circuits from overloading, as it is equipped with an adjustable overload mounting system. This allows for precise calibration of the breaker’s response under different current overload conditions. Additionally, the unit is designed to meet the requirements of UL 1077, which tests it for shock and vibration resistance.

Working Principle

The JLE-2-1-63F-5-B4-130 circuit breaker is designed to detect and respond to abnormal currents. When this type of breaker is triggered, its internal components react to the abnormal current by cutting off the electrical supply, and the breaker goes into its “trip” state. When this happens, the electrical current is disconnected, preventing damages to any connected devices or circuits.

In order to detect the abnormal current, the unit contains a thermal overload element that reacts to heat produced by circuit overloads or short circuits. The breaker will react to these overloads or short circuits by triggering a trip, and the excess current will be diverted to a separate low-voltage circuit. This low-voltage circuit can then be reset when the problem has been corrected.

The JLE-2-1-63F-5-B4-130 also includes an adjustable sensitivity setting. This sensitivity setting can be adjusted to make the breaker more responsive to certain currents. This is useful for protecting circuits from faults, such as short circuits and overloads, which may occur at normal operation levels. It is also useful for protecting against unexpected power surges. By making the unit more sensitive to these currents, the circuit breaker can quickly respond and cut off the current before any damage is done.

Conclusion

The JLE-2-1-63F-5-B4-130 is a specially designed circuit breaker which offers a host of features. It can be used for a variety of applications, from residential to industrial, hazardous environments, and more. Its internal components are designed to detect and react to abnormal currents, and it has an adjustable sensitivity setting which can be tuned to make it more responsive to certain currents. As such, the JLE-2-1-63F-5-B4-130 is an invaluable protection device which can help to ensure the safety and performance of any electrical system.

The specific data is subject to PDF, and the above content is for reference

Latest Products
UPG11-4038-10

CIRCUIT BREAKER MAG-HYDR LEVER

UPG11-4038-10 Allicdata Electronics
299-3-3283-14

CIRCUIT BREAKER MAG-HYDR LEVER

299-3-3283-14 Allicdata Electronics
JLE-1-1REG4-52-3-B1-200-A...

CIR BRKR MAG-HYDR 200A 160VDC

JLE-1-1REG4-52-3-B1-200-A-V Allicdata Electronics
IEGH666-1REC4-72-32.0-01-...

CIR BRKR MAG-HYDR

IEGH666-1REC4-72-32.0-01-V Allicdata Electronics
483-G641-K1M1-A1S0ZN-5A

CIRC BRKR THRM

483-G641-K1M1-A1S0ZN-5A Allicdata Electronics
IEG111-1-52-10.0-01-V

CIR BRKR MAG-HYDR LEVER 10A

IEG111-1-52-10.0-01-V Allicdata Electronics