Allicdata Part #: | JLM-1-1RLS5-30174-150-ND |
Manufacturer Part#: |
JLM-1-1RLS5-30174-150 |
Price: | $ 322.39 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIR BRKR MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | JLM-1-1RLS5-30174-150 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
3 +: | $ 293.07600 |
Series: | * |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Moisture Sensitivity Level (MSL): | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are essential components in the electrical industry, which allows the current to be switched on and off quickly in order to protect electrical systems and equipment from dangerous overloads. One type of breaker is the JLM-1-1RLS5-30174-150 breaker, which is a reverse-logic type circuit breaker with an adjustable time delay. The breaker is designed for use in the control of three-phase circuits of up to 4000A in AC-1 conditions and 1100A in AC-3.
The JLM-1-1RLS5-30174-150 breaker is a versatile device that is suitable for a wide range of applications, ranging from industrial to residential and from commercial to utility. It can be used for direct current (DC) loads or alternating current (AC) loads and can be used in systems with incoming voltage up to 600V. The breaker is available in three different versions, each with its own time delay range, which can be adjusted to provide better protection.
One of the most common applications for the JLM-1-1RLS5-30174-150 is in the control of air conditioning systems. It is designed to protect the system from power surges or sudden changes in current that can damage the equipment. The breaker can also be used to protect electrical systems from overloads due to high current demand or thermal overloading. It can be used to protect motors from overloads and can also be used to control motor starting.
The working principle of the JLM-1-1RLS5-30174-150 circuit breaker involves the sensing of current flow. When the current flow exceeds a preset level, the breaker activates and switches off the electrical circuit. The time delay mechanism prevents the breaker from being immediately reactivated when the current stops, in order to prevent the circuit from being switched back on too quickly. The time delay can be adjusted for different electrical systems and loads, allowing for improved protection.
The JLM-1-1RLS5-30174-150 circuit breaker can be used to protect a wide variety of electrical systems and loads. It is easy to install and can be used in both single and three-phase systems. The adjustable time delay and multiple versions make it a versatile and reliable choice for many types of industrial, commercial, and residential applications.
The specific data is subject to PDF, and the above content is for reference
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A