Allicdata Part #: | 1776-3294-ND |
Manufacturer Part#: |
NAH-20-681 |
Price: | $ 31.85 |
Product Category: | Filters |
Manufacturer: | Cosel USA, Inc. |
Short Description: | LINE FILTER 250VDC/VAC 20A CHAS |
More Detail: | N/A |
DataSheet: | NAH-20-681 Datasheet/PDF |
Quantity: | 2 |
1 +: | $ 28.95480 |
10 +: | $ 28.01930 |
25 +: | $ 27.08520 |
50 +: | $ 26.15130 |
100 +: | $ 25.21730 |
250 +: | $ 22.88240 |
Series: | NAH |
Part Status: | Active |
Filter Type: | Single Phase |
Configuration: | Single Stage |
Voltage - Rated DC: | 250V |
Voltage - Rated AC: | 250V |
Voltage - Rated AC (Phase to Ground/Neutral): | 250V |
Current: | 20A |
Frequency - Operating: | -- |
Applications: | General Purpose |
Approvals: | cURus, VDE |
Operating Temperature: | -40°C ~ 85°C |
Mounting Type: | Chassis Mount |
Termination Style: | Terminal Block |
Inductance: | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
NAH-20-681 is a power line filter module from the NAH series, specifically designed to filter out electromagnetic interference (EMI) from power lines. The module limits the amount of noise that is passed through power line systems, which helps to decrease EMI from spreading. The module can be used in a variety of applications, including electronic devices, industrial machinery, and residential homes.
The module is designed with three components - two capacitors and an inductor. The capacitors act as a low-pass filter, which filters out high-frequency signals. This helps to reduce EMI and other electrical noise caused by signals from other electrical devices. The inductor acts as a common-mode filter, which helps to reduce noise from alternating current (AC). By combining these two components, the module helps to reduce EMI and AC noise from being passed through power lines.
The NAH-20-681 module can be used in a variety of applications, including medical devices, communication systems, and industrial machines. For example, the module can be used in power lines for maintaining signal integrity in medical imaging systems and reducing EMI noise in communication systems. It can also be used in industrial machines to reduce unexpected shutdowns caused by electrical noise. In residential homes, the module can help to reduce EMI interference from electronic devices, such as TVs and computers.
In addition to providing EMI filtering, the NAH-20-681 module can help to reduce power losses. This is because it can reduce the amount of power that is lost due to the formation of parasitic capacitance in power lines. This helps to improve the efficiency of power lines, which can result in cost savings.
The NAH-20-681 module is designed to operate in a temperature range of -30°C to 85°C. This ensures that the module is able to provide reliable filtering performance, even in extreme temperatures. The module also has an internal safety system that helps to protect it from overvoltage conditions. This helps to ensure that the module is able to provide reliable performance, even in extreme conditions.
Overall, the NAH-20-681 module is an ideal solution for filtering out EMI and other electrical noise from power lines. The module is designed with two capacitors and an inductor, which helps to reduce EMI and AC noise from spreading. Furthermore, the module can help to reduce power losses and provide reliable performance even in extreme temperatures. As such, the module can provide reliable filtering performance in a variety of applications, from medical devices to residential homes.
The specific data is subject to PDF, and the above content is for reference
LINE FILTER 250VAC 20A CHASS MNT
LINE FILTER 125/250VAC 4A TH
LINE FILTER 500VAC 100A CHASSIS
LINE FILTER 480VAC 50A CHASS MNT
LINE FILTER 480/520VAC 36A CHASS
LINE FILTER 480VAC 65A CHASS MNT