Allicdata Part #: | S506-32-R-ND |
Manufacturer Part#: |
S506-32-R |
Price: | $ 4.70 |
Product Category: | Circuit Protection |
Manufacturer: | Eaton |
Short Description: | FUSE GLASS 32MA 250VAC 5X20MM |
More Detail: | N/A |
DataSheet: | S506-32-R Datasheet/PDF |
Quantity: | 1000 |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
5 +: | $ 4.27014 |
Package / Case: | 5mm x 20mm |
DC Cold Resistance: | 21 Ohms |
Size / Dimension: | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) |
Color: | -- |
Operating Temperature: | -- |
Approvals: | BSI, CCC, IMQ, SEMKO, UL, VDE |
Melting I²t: | 0.0051 |
Breaking Capacity @ Rated Voltage: | 35A |
Mounting Type: | Holder |
Series: | S506 |
Response Time: | Slow |
Voltage Rating - AC: | 250V |
Current Rating: | 32mA |
Fuse Type: | Cartridge, Glass |
Moisture Sensitivity Level (MSL): | -- |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses are electrical components which play an important role in protecting electrical circuits from overloading. They are designed to protect sensitive equipment and wiring from short circuits, overloads, and other electrical hazards. The S506-32-R is a specific type of fuse which is designed to specifically protect certain types of industrial applications. By understanding the application field and working principle of the S506-32-R, it is possible to maintain the electrical system in a safe and effective manner.
The main application field of the S506-32-R fuse is in medium voltage industrial applications. It is used to protect capacitor banks, motors, starter boxes, generators, reactors, and switchgears. In these critical industrial applications, it is essential that the fuse does not break before its rated current is reached. If it does, this could lead to system damage or even losses of life. Therefore, it is important to choose a fuse with a proper rating for the application where it is used.
In medium voltage applications, the S506-32-R fuse is typically used in combination with an intermediate disconnect switch. The switch is used to ensure that the fuse is the only point of protection against short circuits and electrically hazardous situations. The combination of the switch and the fuse provides excellent protection to the system and helps to isolate the system from any short circuits or other adverse conditions. The switch also ensures that the fuse is the only point of protection against overloads.
The working principle of the S506-32-R fuse is simple and effective. When an electrical current is passed through the fuse, it is heated. When the current exceeds the fuse\'s rating, the heat generated causes a rapid melting of the fuse wire, which breaks the circuit and prevents any further current flow. The rated current is determined by the diameter and material of the fuse wire. This type of fuse is very effective in high current situations, as it can prevent further current flow as soon as the current exceeds its rating.
The S506-32-R fuse is designed for medium voltage applications. Its rated current is generally higher than that of a low-voltage fuse, and its interrupting rating is usually higher as well. As it is made of material suitable for high current situations, it provides excellent protection against short circuits and other electrical hazards. The fuse is easy to install and its operation is simple and dependable, ensuring that it will continue to provide protection throughout its lifespan.
In conclusion, the S506-32-R fuse is designed specifically for medium voltage industrial applications. As it is designed for high current situations, it is an effective component in protecting the circuit from short circuits and other hazardous conditions. It is easy to install and its working principle is simple and reliable, ensuring that it will continue to provide protection throughout its lifespan. Therefore, understanding the application field and working principle of the S506-32-R is essential in order to maintain the electrical system in a safe and effective manner.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
BK/S506-2.5-R | Eaton | 0.67 $ | 7241 | FUSE GLASS 2.5A 250VAC 5X... |
BK/S506-5-R | Eaton | 0.67 $ | 6202 | FUSE GLASS 5A 250VAC 5X20... |
BK/S506-2-R | Eaton | 0.67 $ | 5627 | FUSE GLASS 2A 250VAC 5X20... |
BK/S506-3.15-R | Eaton | 0.67 $ | 4020 | FUSE GLASS 3.15A 250VAC 5... |
BK/S506-4-R | Eaton | 0.67 $ | 3996 | FUSE GLASS 4A 250VAC 5X20... |
BK/S506-1-R | Eaton | 0.67 $ | 1688 | FUSE GLASS 1A 250VAC 5X20... |
BK/S506-V-15-R | Eaton | 2.07 $ | 1000 | FUSE GLASS 15A 250VAC 5X2... |
TR2/S506-V-6.3R | Eaton | 2.18 $ | 1000 | FUSE GLASS 6.3A 250VAC 5X... |
TR2/S506-V-32-R | Eaton | 2.21 $ | 1000 | S506 32MA BUSS TD TR2 150... |
BK/S506-15-R | Eaton | 2.23 $ | 1000 | FUSE GLASS 15A 250VAC 5X2... |
S506-1.25-R | Eaton | 2.68 $ | 1000 | FUSE GLASS 1.25A 250VAC 5... |
BK/S506-V-200-R | Eaton | 2.79 $ | 1000 | FUSE GLASS 200MA 250VAC 5... |
BK/S506-V-250-R | Eaton | 2.79 $ | 1000 | FUSE GLASS 250MA 250VAC 5... |
BK/S506-V-315-R | Eaton | 2.79 $ | 1000 | FUSE GLASS 315MA 250VAC 5... |
BK/S506-V-400-R | Eaton | 2.79 $ | 1000 | FUSE GLASS 400MA 250VAC 5... |
S506-1.6-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 1.6A 250VAC 5X... |
S506-1-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 1A 250VAC 5X20... |
S506-2.5-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 2.5A 250VAC 5X... |
S506-2-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 2A 250VAC 5X20... |
S506-3.15-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 3.15A 250VAC 5... |
S506-4-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 4A 250VAC 5X20... |
S506-500-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 500MA 250VAC 5... |
S506-5-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 5A 250VAC 5X20... |
S506-630-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 630MA 250VAC 5... |
S506-800-R | Eaton | 2.81 $ | 1000 | FUSE GLASS 800MA 250VAC 5... |
BK/S506-63-R | Eaton | 2.9 $ | 1000 | FUSE GLASS 63MA 250VAC 5X... |
BK/S506-V-32-R | Eaton | 2.93 $ | 1000 | FUSE GLASS 32MA 250VAC 5X... |
BK/S506-V-40-R | Eaton | 2.93 $ | 1000 | FUSE GLASS 40MA 250VAC 5X... |
BK/S506-V-63-R | Eaton | 2.93 $ | 1000 | FUSE GLASS 63MA 250VAC 5X... |
BK/S506-V-80-R | Eaton | 2.93 $ | 1000 | FUSE GLASS 80MA 250VAC 5X... |
S506-6.3-R | Eaton | 3.09 $ | 1000 | FUSE GLASS 6.3A 250VAC 5X... |
BK8/S506-4-R | Eaton | 0.0 $ | 1000 | FUSE GLASS 4A 250VAC 5X20... |
TR/S506-V-250-R | Eaton | 0.0 $ | 1000 | FUSE GLASS 250MA 250VAC 5... |
S506-15-R | Eaton | 3.75 $ | 1000 | FUSE GLASS 15A 250VAC 5X2... |
S506-12.5-R | Eaton | 3.88 $ | 5 | FUSE GLASS 12.5A 250VAC 5... |
S506-100-R | Eaton | 4.23 $ | 1000 | FUSE GLASS 100MA 250VAC 5... |
S506-315-R | Eaton | 4.23 $ | 1000 | FUSE GLASS 315MA 250VAC 5... |
S506-400-R | Eaton | 4.23 $ | 1000 | FUSE GLASS 400MA 250VAC 5... |
S506-8-R | Eaton | 4.29 $ | 1000 | FUSE GLASS 8A 250VAC 5X20... |
S506-125-R | Eaton | 4.35 $ | 1000 | FUSE GLASS 125MA 250VAC 5... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL