UPG1-4470-2 Circuit Protection |
|
| Allicdata Part #: | UPG1-4470-2-ND |
| Manufacturer Part#: |
UPG1-4470-2 |
| Price: | $ 0.00 |
| Product Category: | Circuit Protection |
| Manufacturer: | Sensata-Airpax |
| Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
| More Detail: | N/A |
| DataSheet: | UPG1-4470-2 Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 1 +: | 0.00000 |
| Series: | UPG |
| Part Status: | Obsolete |
| Lead Free Status / RoHS Status: | -- |
| Breaker Type: | Magnetic (Hydraulic Delay) |
| Moisture Sensitivity Level (MSL): | -- |
| Current Rating: | -- |
| Number of Poles: | 1 |
| Actuator Type: | Lever |
| Illumination: | -- |
| Illumination Voltage (Nominal): | -- |
| Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are an integral part of any electrical circuit and can be used to protect the circuit from overloads and unintended short circuits. The UPG1-4470-2 is a type of circuit breaker which provides both protection and control for a circuit. The circuit breaker can be used in a wide variety of applications, from high power equipment to low voltage control circuits.
Applications
The UPG1-4470-2 can be used in a number of different types of applications, where the device is used to protect the circuit from overcurrents and short circuits. The device can be used in the following types of applications:
- High voltage power systems
- Distribution boards
- Industrial control systems
- Lighting circuits
- Appliance control circuits
- Building management systems
In addition to these applications, the UPG1-4470-2 can also be used to provide protection for data and communication lines from lightning and other sources of EMC interference. This type of protection can help to ensure that data and communication lines remain operational even in harsh environmental conditions.
Working Principle
The UPG1-4470-2 circuit breaker operates on the principle of thermal-magnetic protection. This means that the circuit breaker consists of two separate parts: a thermal trip unit and a magnetic trip unit. The thermal trip unit monitors the temperature of the circuit and will trip if the temperature exceeds the device\'s preset temperature limit. The magnetic trip unit monitors the current in the circuit and will trip if it exceeds the preset current limit.
When the thermal trip unit senses a temperature increase above its preset limit, it will trip the circuit breaker and disconnect the circuit from the power supply. The magnetic trip unit will then take over the protection function, and if the current exceeds its preset limit, it will also trip the circuit. In either case, the circuit will be disconnected from the power supply, protecting it from possible damage due to excessive current or temperature.
The UPG1-4470-2 also includes a manual reset feature, which can be used to reset the circuit breaker after it has been tripped. This allows the circuit to be reconnected to the power supply after it has cooled down or the current returned to a safe level.
Conclusion
The UPG1-4470-2 is a type of circuit breaker which provides both protection and control for the circuit. It is designed to be used in a wide variety of applications, including high voltage power systems, distribution boards, industrial control systems, lighting circuits, appliance control circuits, and building management systems. The device works on the principle of thermal-magnetic protection, with a thermal trip unit and a magnetic trip unit which provide protection against overcurrents and short circuits. The device also includes a manual reset feature, which allows the device to be reset after it has been tripped.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| UPG1-20035-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-4038-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-26174-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-1REC2-2730-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| PPM4MK1-UPG15 | Equinox Tech... | 542.85 $ | 1000 | UPGRADE PPM4 ATMEL AT91SA... |
| UPG11-36350-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-20035-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-20005-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG12-24644-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-25758-7 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-36350-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG111-5651-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-34549-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-5782-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-1REC4-34557-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG13-5920-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-4038-11 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-1REC5-34476-3 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
| UPG1-4683-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-35203-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-20035-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-1REC2-1542-8 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-4038-12 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG13-1226-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-1REC2-4683-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-9953-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-1REC4-28280-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-26359-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-1REG4-34843-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-20403-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-25759-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-4470-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-5184-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG12-25700-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-31777-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| ISPNANO-UPG10AR | Equinox Tech... | 115.47 $ | 1000 | ISP NANO RUN TIME LICENSE |
| UPG11-26174-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG11-26541-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG1-1REC4-28728-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| UPG12-22721-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A
UPG1-4470-2 Datasheet/PDF