UPG66-4076-1 Circuit Protection |
|
Allicdata Part #: | UPG66-4076-1-ND |
Manufacturer Part#: |
UPG66-4076-1 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | UPG66-4076-1 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | UPG |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are essential components of all types of electrical systems. They are designed to protect systems from short circuit, overload, and current surges. By doing so, they enable us to safely connect and disconnect current throughout our electrical systems. UPG66-4076-1 is one type of circuit breaker, found in many high-efficiency power supplies. In this paper, we’ll discuss its application field and working principle.
Application Field
UPG66-4076-1 circuit breakers are typically used in high-efficiency power supplies. These include linear, pulsed, and switchers. These systems may include low-voltage direct current (DC) sources, high-voltage components, transformers, and other circuit components. They are also widely used in solar power systems, in order to protect systems from voltage overload.
Working Principle
In order to understand the working principle of the UPG66-4076-1 circuit breaker, it is important to first discuss the concept of current limiting. This is because the circuit breaker is designed to limit the current flowing through the electrical system. When the current reaches its peak value, the circuit breaker rapidly opens and closes, limiting the amount of current that is allowed to flow. In this way, it can protect the system from overloads, surges, and short circuits.
The UPG66-4076-1 circuit breaker is also designed to withstand high inrush currents, which can occur during system start-up or shut-down. It can also detect and protect against overvoltage conditions, which can cause damage to other components.
In addition to current limiting and protection, the UPG66-4076-1 circuit breaker can also be used to isolate certain components or energy sources. This can be done by simply opening and closing the circuit, which will cause the circuit breaker to open and close, thereby isolating the components from the rest of the system.
The UPG66-4076-1 circuit breaker can be used in a variety of systems, including static and dynamic systems, as well as in pulse and switched systems. By accurately measuring the electrical current through the circuit, it is possible to accurately control the amount of current through the system.
The UPG66-4076-1 circuit breaker is a an essential part of any power system, providing protection against short circuits, overloads, and surges. It is designed to withstand high inrush currents and can protect against overvoltage conditions. It can also be used to isolate electrical components or energy sources. With its numerous features, it is one of the most reliable circuit breakers currently available.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
UPG66-1-61-303-01 | Sensata-Airp... | 64.28 $ | 1000 | CIR BRKR 30A 250VAC 65VDC |
UPG62-6149-3 | Sensata-Airp... | 121.51 $ | 1000 | CIR BRKR 30A 250VAC 65VDC |
PPM3A1-UPG6M | Equinox Tech... | 0.0 $ | 1000 | UPGRADE PPM3 LABVIEW DEVE... |
UPG66-27823-1 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
UPG666-35092-10 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
UPG60-7601-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG60-7601-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG60-7601-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG60-7601-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG60-7601-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG60-7601-7 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-2246-469 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-24104-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-24104-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-24104-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-24104-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-24104-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-4573-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC2-4573-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC4-34931-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC5-34557-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-1REC5-34679-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-20035-8 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-20452-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-20452-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-20452-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-20452-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-20452-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-20452-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-18 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-19 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-21 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-36 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPG6-21616-40 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A