UPGF6-30513-28 Circuit Protection |
|
Allicdata Part #: | UPGF6-30513-28-ND |
Manufacturer Part#: |
UPGF6-30513-28 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | UPGF6-30513-28 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Specifications
Series: | UPG |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 1 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Introduction
A UPGF6-30513-28 circuit breaker is a device used to protect an electrical circuit from excessive current. Circuit breakers are an important part of electrical safety equipment and can help protect a circuit from harmful surges, which can occur due to lightning strikes, power outages, or other conditions.The UPGF6-30513-28 circuit breaker is designed for both residential and commercial applications, as well as for applications in industrial plants. It is rated at a maximum current of 305A and is one of the most popular circuit breakers on the market today.Application Fields
The UPGF6-30513-28 circuit breaker is widely used in residential, commercial, and industrial settings. In residential applications, it is suitable for any multi-breaker electrical box with a standard 60 amp rating. In commercial applications, the UPGF6-30513-28 circuit breaker can provide short circuit and overload protection to industrial motors and other large equipment. It can also be used in industrial plants to protect circuits from hazardous overloads or short circuits.Working Principle
The UPGF6-30513-28 circuit breaker has two main components: the current-limiting device and the short-circuit device. These two components work together to protect the circuit in case of an overload or short circuit.When an overload or short circuit occurs, the current-limiting device will detect the overload and quickly reduce the circuit\'s current. The short-circuit device will then detect the reduction in current and immediately disconnect the circuit from the power source. When the circuit is disconnected, the current will reduce to a safe level and the circuit breaker will reset itself, restoring power to the circuit. If the overload is caused by a fault in the circuit, the circuit breaker will trip again and power to the circuit will be cut off. To restore the circuit, the fault in the circuit must be corrected and the circuit breaker must be reset again.Conclusion
The UPGF6-30513-28 circuit breaker is a reliable and important device for electrical circuit protection. It is suitable for both residential and commercial applications, as well as for industrial plants, and is capable of providing short circuit and overload protection. Its current-limiting and short-circuit devices work together to protect circuits from damage due to overloads and short circuits.The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "UPGF" Included word is 40
Part Number | Manufacturer | Price | Quantity | Description |
---|
UPGF6-1REC4-31870-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-1REC4-31874-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF62-28752-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF62-28802-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-27822-18 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-27822-21 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-27822-22 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-27822-23 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-27822-24 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-29486-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-29848-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-29848-18 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-29848-19 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-29848-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-29848-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30348-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30348-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30348-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30348-25 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30348-30 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30348-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-00 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-02 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-04 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-06 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-08 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-14 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-18 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-22 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-24 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-26 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-28 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30421-30 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30479-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30479-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30479-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30479-25 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGF6-30479-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
Latest Products
UPG11-4038-10
CIRCUIT BREAKER MAG-HYDR LEVER
299-3-3283-14
CIRCUIT BREAKER MAG-HYDR LEVER
JLE-1-1REG4-52-3-B1-200-A...
CIR BRKR MAG-HYDR 200A 160VDC
IEGH666-1REC4-72-32.0-01-...
CIR BRKR MAG-HYDR
483-G641-K1M1-A1S0ZN-5A
CIRC BRKR THRM
IEG111-1-52-10.0-01-V
CIR BRKR MAG-HYDR LEVER 10A