UPL1-34177-70 Circuit Protection |
|
Allicdata Part #: | UPL1-34177-70-ND |
Manufacturer Part#: |
UPL1-34177-70 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | UPL1-34177-70 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | UPL |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 1 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
.Circuit Breakers: UPL1-34177-70 Application Field and Working Principle
Circuit breakers are essential pieces of equipment in electrical systems, providing protection to electrical circuits in cases of overcurrent or a potentially dangerous situation. The UPL1-34177-70 circuit breaker offers reliable protection against overcurrent and short circuits in medium-voltage networks and substations. This article will discuss the application field and working principle of the UPL1-34177-70 circuit breaker.
Application Field and Considerations
The UPL1-34177-70 circuit breaker is designed for use as a low-voltage circuit breaker in medium-voltage networks and substations. It is suitable for applications with a rated voltage of up to 34.5 kV and currents of up to 7.5kA. The breaker can be used as a single-pole breaker or in a multi-pole configuration. The maximum size of the breaker is governed by the size of the cubicle in which it is installed.
When selecting the UPL1-34177-70 circuit breaker, a number of factors should be taken into consideration. The inrush current of the circuit must be below a certain limit to ensure the safe operation of the breaker and to prevent any damage to downstream components. It is also important to ensure that the area is free from combustible gases or vapor that could potentially react with the arcing contacts of the breaker. The breaker is best suited for indoor use but can also be used outdoors if it is adequately weatherproofed.
Working Principle
The UPL1-34177-70 circuit breaker works using an overcurrent protection system. When an overcurrent passes through the circuit, this triggers a release mechanism which opens the contacts of the breaker and interrupts the circuit. The contacts of the breaker are rated for up to 7.5kA. At lower currents, the breaker will be able to trip safely without causing any damage to the downstream components.
The release mechanism of the circuit breaker consists of two components, a spring and a release. When an overcurrent is detected, the spring is compressed, releasing the release which then opens the contacts of the breaker. The contacts of the breaker are designed to avoid arcing when they open, making the breaker safe to use in environments with combustible gases or vapor. The contacts are also designed to minimize wear and tear from repeated use, ensuring a long service life.
Advantages of the UPL1-34177-70 Circuit Breaker
The UPL1-34177-70 circuit breaker offers a number of advantages over traditional circuit breakers. It is designed for medium-voltage networks and substations, making it a suitable choice for applications with higher currents and voltages than a standard circuit breaker. The circuit breaker is also designed with a release mechanism that prevents arcing, making it suitable for use in areas with combustible gases or vapor. The design also ensures that the contacts of the breaker remain in good condition, reducing wear and tear and ensuring a long service life.
The UPL1-34177-70 circuit breaker is a reliable and safe choice for medium-voltage networks and substations. It offers reliable protection from overcurrent and short circuits, as well as being suitable for use in areas with combustible gases or vapor. The design of the contacts and release mechanism also ensures that the breaker will last for a long time, reducing wear and tear and making it a cost-effective choice.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
UPL121 | Cinch Connec... | 9.16 $ | 1000 | CONN BNC PLUG STR 75OHM S... |
UPL110-026 | Cinch Connec... | 10.96 $ | 1000 | CONN 1.6/5.6 PLG STR 75OH... |
UPL143-026 | Cinch Connec... | 25.58 $ | 1000 | CONN SMZ PLUG STR 75 OHM ... |
UPL11-1-61-403 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAG-HYDR 40A 65V... |
UPL1-1-72-302 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAG-HYDR 250VAC ... |
UPL1-1-72-502 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAGHYDR 5A 250VA... |
UPL1-1-72-203 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR 20A 250VAC 65VDC |
UPL1-1-72-303 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR 30A 250VAC 65VDC |
UPL1-1-72-403 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR 40A 250VAC 65VDC |
UPL1-1-72-503 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR 50A 250VAC 65VDC |
UPL111-33319-1 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
UPL1110-20458-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1110-25351-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1110-25459-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-1REC4-22706-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-27214-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-28673-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-2REC2-20707-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-30302-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-30302-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-34807-50 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-1548-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-7007-11 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-755-13 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL1111-7617-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-1REC2-3307-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-1REC4-26040-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-2026-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-21415-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-21415-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-22096-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-22854-004 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-23551-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-23736-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-23736-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-25620-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-25684-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-26883-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-27227-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPL111-2758-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A