Allicdata Part #: | W28-X1015-3.70-ND |
Manufacturer Part#: |
W28-X1015-3.70 |
Price: | $ 1.87 |
Product Category: | Circuit Protection |
Manufacturer: | TE Connectivity Potter & Brumfield Relays |
Short Description: | CIR BRKR THRM |
More Detail: | N/A |
DataSheet: | W28-X1015-3.70 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Contains lead / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
100 +: | $ 1.69785 |
Series: | W28 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 3.7A |
Voltage Rating - AC: | 250V |
Voltage Rating - DC: | 32V |
Number of Poles: | 1 |
Actuator Type: | Push to Reset |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are electrical devices designed to protect electrical circuits, preventing dangerous overloads and short circuits. The W28-X1015-3.70 is a type of circuit breaker that is suitable for medium-voltage line protection applications with rated voltage up to and including 12 kV. It is a three-pole, pole interval discrimination breaker with a rated current of 925 amperes.
Application
The W28-X1015-3.70 circuit breaker is typically used in medium-voltage applications such as switchgears, primary substation switchgear, and distribution switchgear. It is used to protect feeders, junction points, bus bars, or other high current-carrying circuits. It is also used for power factor protection, as well as for protection against external faults, lightning, and overvoltages. In addition, the W28-X1015-3.70 can be used in transformer applications to protect the transformer from overload.
Working Principle
When a fault such as an overload or short circuit occurs, the W28-X1015-3.70 circuit breaker senses the abnormal current and trips, automatically interrupting the flow of power in the circuit. The circuit breaker is designed with two cut-off mechanisms: mechanical and thermal. The mechanical cut-off mechanism is designed to trip when a certain current level is exceeded. The thermal cut-off mechanism is designed to trip if the circuit continues to draw abnormally high current for an extended period of time. If a fault or overload occurs, the circuit breaker\'s thermal overload characteristic will begin to kick in, allowing for a current path to the fault point that is only just large enough for the protection of downstream equipment.
The W28-X1015-3.70 also offers protection against reverse current and spurious currents. Its fixed-time overcurrent (FTCO) feature provides protection against reverse faults, minimizing the possibility of damage from single-fault pickups. The W28-X1015-3.70 also features a programmable auto-reclose voltage, which is designed to automatically apply a safe level of voltage following a fault trip. This feature allows for circuit protection that is both effective and reliable.
In addition, the W28-X1015-3.70 offers the advantage of a high interrupting rating, allowing it to be used for high-energy applications. Its compact design also allows for easy installation in existing systems, whether it is installed in indoor or outdoor environments.
Overall, the W28-X1015-3.70 is an ideal choice for medium-voltage application protection. It is designed to provide reliable protection and safety, as well as affordability, ease of installation and maintenance.
The specific data is subject to PDF, and the above content is for reference