Allicdata Part #: | PB2854-ND |
Manufacturer Part#: |
W92-X112-2 |
Price: | $ 39.10 |
Product Category: | Circuit Protection |
Manufacturer: | TE Connectivity Potter & Brumfield Relays |
Short Description: | CIR BRKR MAG-HYDR 2A 277VAC |
More Detail: | N/A |
DataSheet: | W92-X112-2 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Contains lead / RoHS Compliant |
12 +: | $ 35.53930 |
Series: | W9 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Current Rating: | 2A |
Voltage Rating - AC: | 277V |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are electrical devices designed to shut off electrical power to circuits when excessive current or voltage is detected. W92-X112-2 is a two-pole, multi-function circuit breaker designed for use in the residential, commercial, and industrial markets. It is designed to be a cost-effective and reliable circuit protection solution, protecting a wide range of appliances or machinery from battery shorting, overloads, and other electrical faults.
The W92-X112-2 circuit breaker is used in a variety of applications in residential, commercial, and industrial settings. It can be used for circuit protection in common applications such as HVAC systems, electrical motors, lighting loads, air conditioning, refrigeration, pumps, food service equipment, agricultural equipment, and other similar loads.
The W92-X112-2 circuit breaker is designed to protect against current surges, overloads, and short circuits. It is designed to open the circuit relay and shut off power to the circuit when it detects a fault. It will reset itself once the fault clears. The W92-X112-2 is UL 1077-Listed and has an off-state current capacity of 5 times its rated current.
The W92-X112-2 features an internal system with a thermal and magnetic trip unit. The thermal trip unit is designed to sense current and immediately disconnect the circuit as soon as an overload is detected. The magnetic trip unit senses current flowing through the circuit and will open the circuit relay after a predetermined amount of time.
The W92-X112-2 has a number of configurability settings which allow it to be adjusted for different applications and conditions. The current rating can be adjusted from 6A to 20A, the voltage rating can be adjusted from 120VAC to 277VAC, and the temperature range can be adjusted from -20°C to 80°C. It also has an adjustable set point which can be adjusted from 0.04A to 0.7A and a maximum fault interrupting capacity of 6000A.
The W92-X112-2 is an efficient and cost-effective way to protect against electrical faults and overloads. It is designed to be reliable and easy to install, and is UL 1077-Listed for safety. With its adjustable settings and wide range of applications, it is an excellent choice for residential, commercial, and industrial circuit protection.
The specific data is subject to PDF, and the above content is for reference
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A