0679L2000-05 Allicdata Electronics
Allicdata Part #:

507-1989-2-ND

Manufacturer Part#:

0679L2000-05

Price: $ 0.10
Product Category:

Circuit Protection

Manufacturer:
Short Description: FUSE BRD MNT 2A 125VAC/VDC
More Detail: N/A
DataSheet: 0679L2000-05 datasheet0679L2000-05 Datasheet/PDF
Quantity: 15000
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
5000 +: $ 0.09030
10000 +: $ 0.08428
Stock 15000Can Ship Immediately
$ 0.1
Specifications
Series: 0679L
Packaging: Tape & Reel (TR) 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Fuse Type: Board Mount (Cartridge Style Excluded)
Current Rating: 2A
Voltage Rating - AC: 125V
Voltage Rating - DC: 125V
Response Time: Fast
Package / Case: 2410 (6125 Metric)
Mounting Type: Surface Mount
Breaking Capacity @ Rated Voltage: 50A AC, 300A DC
Melting I²t: 0.68
Approvals: cURus
Operating Temperature: -55°C ~ 125°C
Color: --
Size / Dimension: 0.240" L x 0.100" W x 0.110" H (6.10mm x 2.54mm x 2.79mm)
DC Cold Resistance: 0.041 Ohms
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Fuses
The 0679L2000-05 is an essential component of a power system. It is designed to protect the system from overcurrent or overvoltage conditions that can otherwise lead to catastrophic destruction of the system. Knowing the application field and working principle of this fuse is very important and beneficial in ensuring the correct and safe operation of the system.
Application Field
Originally designed for use in high power systems, the 0679L2000-05 fuse is now also used in other applications such as HVAC systems and motor drives. It is also used in circuit protection, overcurrent protection, ground fault protection, arc-fault protection and other DC and AC power applications. It is also used in temperature protection, motor overload protection, coil/motor burnout protection, power output protection and surge protection.
Working Principle
The 0679L2000-05 fuse is a type of overcurrent protection device that operates when an excessive current passes through it. The device consists of a metal strip and a wire-wound element, usually encased in a ceramic housing. When an overcurrent passes through the fuse, the metal strip melts and the wire-wound element breaks its connectivity, thereby initiating the disconnection of the system. This ensures that equipment or components connected to the system are protected from the overcurrent.
Fuse Selection
Given the wide range of applications in which the 0679L2000-05 fuse can be used, careful consideration must be taken when selecting the proper fuse for a particular system. The main aspects to consider when selecting a fuse are the current and voltage ratings of the fuse and the amperage of the circuit. The fuse must have a rating that is suitable for the intended application. For instance, if the application requires the 0679L2000-05 fuse to be connected to a circuit of 50 amps, then the fuse must have a amperage rating of more than 50 amps. It is important to remember that an undersized fuse can cause equipment damage or overheating due to slow operations.
Operation Modes
The 0679L2000-05 fuse has two types of operation: the regular operation mode and the fault operation mode. In regular operation mode, the fuse will remain in the on position even if an overload or a short circuit exists in the system. In fault operation mode, the fuse will trip if a fault occurs, thereby disconnecting the system from the power source and preventing further system damage. It is important to note that the fuse can only trip in fault operation mode and not in regular operation mode.
Other Considerations
When using 0679L2000-05 fuses, it is also important to ensure that the fuse is properly mounted and located in a suitable area where temperatures and voltages will remain within acceptable levels. As such, the fuse should be installed in a cool, dry and ventilated area away from direct sunlight and flammable materials. It is also important to ensure that the fuse is securely mounted and that all connections are secure to ensure optimal operation. Additionally, the fuse must be kept clean and free of dust and debris to ensure proper operation and to avoid extra load on the system and that the wires to the fuse are properly insulated to protect the system from short circuits. In conclusion, the 0679L2000-05 is a type of fuse that is widely used in a variety of applications. Knowing its application fields and working principle is essential in ensuring its safe and proper operation. It is important to carefully consider all aspects such as current ratings, voltage ratings and fuse amperage when selecting the correct fuse. Proper mounting and insulation is also necessary to ensure optimal operation.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "0679" Included word is 40
Part Number Manufacturer Price Quantity Description
0679130002 Molex, LLC 0.0 $ 1000 CONN SD CARD PUSH-PUSH R/...
0679558001 Molex, LLC -- 1000 CONN SD CARD PUSH-PUSH R/...
0679101002 Molex, LLC 1.16 $ 3600 CONN PCI EXP MINI FEMALE ...
0679100002 Molex, LLC -- 1000 CONN PCI EXP MINI FEMALE ...
0679105700 Molex, LLC -- 17500 CONN PCI EXP MINI FEMALE ...
0679H0250-05 0.09 $ 5000 FUSE BRD MNT 250MA 350VAC...
0679H1500-05 0.09 $ 5000 FUSE BOARD MNT 1.5A 350VA...
0679H2000-05 0.09 $ 5000 FUSE BOARD MNT 2A 350VAC ...
0679H3000-05 0.09 $ 5000 FUSE BOARD MNT 3A 350VAC ...
0679H5000-05 0.09 $ 5000 FUSE BOARD MNT 5A 350VAC ...
0679H9100-05 0.09 $ 5000 FUSE BOARD MNT 10A 350VAC...
0679H9150-05 0.09 $ 5000 FUSE BOARD MNT 15A 350VAC...
0679L9100-05 0.1 $ 5000 FUSE BRD MNT 10A 125VAC/V...
0679L0250-05 0.1 $ 20000 FUSE BRD MNT 250MA 125VAC...
0679L2000-05 0.1 $ 15000 FUSE BRD MNT 2A 125VAC/VD...
0679L1000-05 0.1 $ 5000 FUSE BRD MNT 1A 125VAC/VD...
0679L4000-05 0.1 $ 5000 FUSE BRD MNT 4A 125VAC/VD...
0679L5000-05 0.1 $ 5000 FUSE BRD MNT 5A 125VAC/VD...
0679L9150-05 0.13 $ 5000 FUSE BRD MNT 15A 125VAC/V...
0679L9200-05 0.13 $ 5000 FUSE BRD MNT 20A 125VAC/V...
0679L9200-01 0.14 $ 2000 FUSE BRD MNT 20A 125VAC/V...
0679H0500-05 0.09 $ 1000 FUSE BRD MNT 500MA 350VAC...
0679L2500-05 0.1 $ 1000 FUSE BRD MNT 2.5A 125VAC/...
0679L0750-01 0.13 $ 1000 FUSE BRD MNT 750MA 125VAC...
0679L0630-01 0.13 $ 1000 FUSE BRD MNT 630MA 125VAC...
0679H9120-01 0.13 $ 1000 FUSE BOARD MNT 12A 350VAC...
0679L3500-01 0.13 $ 1000 FUSE BRD MNT 3.5A 125VAC/...
0679H8000-01 0.13 $ 1000 FUSE BOARD MNT 8A 350VAC ...
0679H1250-01 0.13 $ 1000 FUSE BRD MNT 1.25A 350VAC...
0679L3000-01 0.13 $ 1000 FUSE BRD MNT 3A 125VAC/VD...
0679L1500-01 0.13 $ 1000 FUSE BRD MNT 1.5A 125VAC/...
0679L2500-01 0.13 $ 1000 FUSE BRD MNT 2.5A 125VAC/...
0679L4000-01 -- 1000 FUSE BRD MNT 4A 125VAC/VD...
0679H3000-01 0.13 $ 1000 FUSE BOARD MNT 3A 350VAC ...
0679H0375-01 0.13 $ 1000 FUSE BRD MNT 375MA 350VAC...
0679H0750-01 0.13 $ 1000 FUSE BRD MNT 750MA 350VAC...
0679H0630-01 0.13 $ 1000 FUSE BRD MNT 630MA 350VAC...
0679L1000-01 0.13 $ 1000 FUSE BRD MNT 1A 125VAC/VD...
0679L7000-01 0.13 $ 1000 FUSE BRD MNT 7A 125VAC/VD...
0679L0500-01 0.13 $ 1000 FUSE BRD MNT 500MA 125VAC...
Latest Products
3404.0011.11

FUSE BRD MNT 1.6A 125VAC/VDC SMD

3404.0011.11 Allicdata Electronics
2060.0048.11

FUSE BOARD MNT 3.15A 125VAC/VDC

2060.0048.11 Allicdata Electronics
2060.0043.11

FUSE BOARD MNT 350MA 125VAC/VDC

2060.0043.11 Allicdata Electronics
2060.0013.11

FUSE BRD MNT 2.5A 125VAC/VDC SMD

2060.0013.11 Allicdata Electronics
2060.0011.11

FUSE BRD MNT 1.6A 125VAC/VDC SMD

2060.0011.11 Allicdata Electronics
2040.0715

FUSE BOARD MNT 1A 250VAC RADIAL

2040.0715 Allicdata Electronics