
Allicdata Part #: | 1300851138-ND |
Manufacturer Part#: |
1300851138 |
Price: | $ 4.85 |
Product Category: | Uncategorized |
Manufacturer: | Molex, LLC |
Short Description: | 12531733005 W/ REVERSE ROTATION |
More Detail: | N/A |
DataSheet: | ![]() |
Quantity: | 1000 |
1 +: | $ 4.41000 |
Series: | * |
Part Status: | Active |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
1300851138, also known as a Laser-Induced Breakdown Spectroscopy (LIBS) system, is a spectroscopy technique used for elemental analysis. It is used to identify chemical composition of unknown samples by analyzing the emissions emitted from the sample as a result of an energetic laser pulse. Utilizing this instrument, analysis will be done through detecting the energies of the emitted signals, frequencies, and spectral information of the sample.
The apparatus, built for use at lab scale and field level, consists of several main components. These components include a laser source, a light collector, a spectroscopy unit, a detector, and a readout system. The laser source is most often a pulsed Nd:YAG or Copper Vapor pumped laser which produces a wavelength that is absorbed by the atom or molecules of the sample. The laser creates a spark which is the source of the emission. The light collector gathers this emission and directs it to the spectroscopy unit. This unit splits the emission into its components and passes it into the detector. The detector then transforms the spectra into electrical signals and delivers the information to the readout system.
The application of 1300851138 is vast and wide, mainly because of its capability for fast and reliable on-site measurements. It is used in scientific research, environmental monitoring, and on-site analysis, where the direct and accurate identification of trace elements and compounds is essential. It can also be used to identify elements in materials, inorganic compounds and in surfaces, soils, rocks, and sediment.
LIBS is also used in the production and qality control. In the production process, on-line LIBS detection may be used to monitor the quality of alloys in processes such as smelting, steel-rolling, and cold-working. It is also used in the fabrication of electronic circuits and semiconductors as quality control system. In addition to this, LIBS is also used to analyze the composition of polymers, textiles, rubber, and paint.
The working principle of 1300851138 is based on the emission spectroscopy technique. The laser interaction creates an intense plasma which is the source of the emission. When the laser pulse directly hits the sample, vapor plume and ablation continues from the sample, and the electric field incident to the plasma induces a strong radiation from the plasma. This radiation is then divided according to their wavelengths and intesity. By detecting the energies of the emitted signals, frequencies, and spectral information of the sample, an accurate chemical composition analysis of the sample can be obtained.
To conclude, 1300851138 is a spectroscopy technique used for elemental analysis. The apparatus consists of a laser source, a light collector, a spectroscopy unit, a detector, and a readout system. Its wide applications extend from scientific research, environmental monitoring, and on-site analysis, to production and quality control. Its working principle is based on the emission spectroscopy technique, where the emission is divided according to their energies, frequencies, and spectral information to obtain a chemical composition analysis of the sample.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
1300940520 | Molex, LLC | 25.98 $ | 1000 | BUS-DROP GRIP .820-1.00" ... |
1300060585 | Molex, LLC | 22.82 $ | 4 | MC 3P MP 6' 18/3 PVCCable... |
KR-1300SCL3X1 | Panasonic - ... | 0.0 $ | 1000 | BATT PACK 1300MAH 3.6V SC... |
KR-1300SCT | Panasonic - ... | 0.0 $ | 1000 | BATTERY NICAD 1.2V 1.3AH ... |
1300990101 | Molex, LLC | 54.33 $ | 1000 | CABLE GRIP 14.2-17.5MM 3/... |
1300990107 | Molex, LLC | 91.04 $ | 1000 | CABLE GRIP RA 16-19MM 3/4... |
13008-003KESZ/HR | Vishay Sprag... | 4.61 $ | 1000 | CAP TANT 1000UF 4V 10% 29... |
13008-072KESZ/HR | Vishay Sprag... | 5.49 $ | 1000 | CAP TANT 22UF 50V 10% 291... |
13008-081MESC/HR | Vishay Sprag... | 6.83 $ | 1000 | CAP TANT 15UF 63V 20% 291... |
1300840052 | Molex, LLC | 2.08 $ | 1000 | CABLE REEL RETRACTING OVE... |
1300850891 | Molex, LLC | 3.47 $ | 1000 | 114310304J2 W/2FMYE; NO C... |
1300860331 | Molex, LLC | 7.62 $ | 1000 | 205350904J5C CABLE REEL W... |
1300620131 | Molex, LLC | 114.61 $ | 1000 | MC 4P M/MFE 10M #14/4 GRA... |
1300070455 | Molex, LLC | 116.31 $ | 1000 | MC 6P MP 30' 16/6 PVC SS |
1300061320 | Molex, LLC | 117.35 $ | 1000 | MC 5P FP 25' 16/5 SOO |
1300080493 | Molex, LLC | 118.87 $ | 1000 | MC 19P M/MP 4M 18/3 & 22/... |
1300990094 | Molex, LLC | 123.26 $ | 1000 | MAX-LOC 90 F3 3/4W/GR .43... |
1300062150 | Molex, LLC | 124.4 $ | 1000 | MC 6P FP 40FT. 16/6 PVC |
1300120389 | Molex, LLC | 131.77 $ | 1000 | MC 9P MFE 9' 16/9 PVC |
1300680096 | Molex, LLC | 132.48 $ | 1000 | QC 4P TEE W/MC ALT-KEY 4P... |
1300640143 | Molex, LLC | 137.09 $ | 1000 | QC 4P M/MFE ST/ST SK 4M 1... |
1300101103 | Molex, LLC | 143.51 $ | 1000 | MC 5P MFE 50' 18/5 PVC |
1300240291 | Molex, LLC | 151.96 $ | 1000 | MC 5P FP 15M ST TRUNK FLE... |
1300640323 | Molex, LLC | 152.9 $ | 1000 | QC 4P M/MFE 90/ST SK 5M 1... |
1300240048 | Molex, LLC | 159.8 $ | 1000 | MC 5P M/MP 25M ST TRUNK |
1300940402 | Molex, LLC | 190.32 $ | 1000 | SR250-U SINGLE U EYE STAI... |
1300500179 | Molex, LLC | 191.14 $ | 1000 | ENET MMJ IND/IND 568B 30M |
1300200228 | Molex, LLC | 208.12 $ | 1000 | CC 11P FR |
1300640334 | Molex, LLC | 209.1 $ | 1000 | QC 4P M/MFE 90/ST SK 7M 1... |
DIODE GENERAL PURPOSE TO220

CB 6C 6#16 SKT RECP

CA08COME36-3PB-44

CA-BAYONET

CB 6C 6#16S SKT PLUG

CAC 3C 3#16S SKT RECP LINE
