| Allicdata Part #: | 1776960-4-ND |
| Manufacturer Part#: |
1776960-4 |
| Price: | $ 0.00 |
| Product Category: | Connectors, Interconnects |
| Manufacturer: | TE Connectivity AMP Connectors |
| Short Description: | CONN BARRIER STRIP 4CIRC 0.375" |
| More Detail: | 4 Circuit 0.375" (9.53mm) Barrier Block Connector,... |
| DataSheet: | 1776960-4 Datasheet/PDF |
| Quantity: | 1000 |
| 1 +: | 0.00000 |
| Top Termination: | Screws |
| Material Flammability Rating: | UL94 V-0 |
| Material - Insulation: | Polypropylene (PP) |
| Operating Temperature: | 105°C |
| Mounting Type: | Chassis, Panel |
| Terminal Screw Finish: | Zinc, Clear Chromate |
| Terminal Screw Material: | Steel |
| Color: | Black |
| Features: | Flange |
| Barrier Type: | 3 Wall (Tri) |
| Bottom Termination: | Solder Turret, Insulated |
| Series: | BC6, Buchanan |
| Wire Gauge: | 12-22 AWG |
| Voltage Rating: | 300V |
| Current Rating: | 20A |
| Number of Rows: | 1 |
| Pitch: | 0.375" (9.53mm) |
| Number of Wire Entries: | 4 |
| Number of Circuits: | 4 |
| Terminal Block Type: | Barrier Block |
| Part Status: | Obsolete |
| Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Barrier blocks are a type of terminal block used as a physical separation barrier between different circuits, enabling separate circuits to interact with one another. They provide a safe environment for electrical wiring, particularly in hazardous areas, and are used for a range of applications, from automotive to heavy industry and home automation. In this article, we will discuss the 1776960-4 application field and working principle, providing in-depth insight for professionals in the field of electrical engineering.
What is a 1776960-4 Terminal Block?
The 1776960-4 terminal block is an UL-Listed terminal block used to provide a separation barrier between two circuits. It is a single-pole authorized safety barrier, with a 5mm shrouded contact that can be used to connect two circuits together without them coming in contact directly. This allows for increased safety, as it prevents the user from coming into contact with any potentially hazardous levels of electricity. Furthermore, the terminal block features an integrated indicator light to alert the user if there is an issue.
1776960-4 Application Fields
The 1776960-4 is designed for use in hazardous areas, such as in industrial plants, oil and gas fields, and marine applications. It is particularly suited for environments that require a dust- and water-tight barrier between circuits. In addition, it has also been designed to meet specific safety requirements for environments such as petrochemical plants, offshore installations, nuclear power plants, and other hazardous industries. Furthermore, the 1776960-4 is suitable for installation in tight and confined areas, thanks to its compact design.
1776960-4 Working Principle
The 1776960-4 terminal block is a single-pole safety barrier designed to provide a separation barrier between two circuits. It works by providing a 5mm shrouded contact for the two circuits to interact with one another, without them coming in contact directly. In addition, the terminal block features an integrated indicator light to alert the user if there is an issue and a mechanical self-locking screw for quick and easy mounting and dismounting.
The 1776960-4 terminal block is designed to create a dust- and water-tight barrier between circuits, thereby ensuring that they are kept safe from any harmful external influences. Furthermore, it is UL-Listed, meeting the safety requirements for the hazardous industries mentioned above, ensuring the highest levels of safety.
Conclusion
In conclusion, the 1776960-4 terminal block is a UL-Listed terminal block used to provide a separation barrier between two circuits. It is a single-pole authorized safety barrier, with a 5mm shrouded contact, an integrated indicator light, and a mechanical self-locking screw for quick and easy mounting and dismounting. The 1776960-4 is designed for use in hazardous areas, such as in industrial plants, oil and gas fields, and marine applications, as well as for environments that require a dust- and water-tight barrier between circuits. As such, it provides a safe environment for electrical wiring, particularly in hazardous areas, and is used for a range of applications, from automotive to heavy industry and home automation.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| 1776242001 | Weidmuller | 2.37 $ | 1000 | TERM BLOCK HDR 13POS VERT... |
| 1776854 | Phoenix Cont... | 4.94 $ | 1000 | TERM BLOCK HDR 18POS 90DE... |
| 2-1776244-0 | TE Connectiv... | 0.0 $ | 1000 | TERM BLOCK RCPT 20POS VER... |
| 1-1776252-5 | TE Connectiv... | 0.0 $ | 1000 | TERM BLOCK 15POS 45DEG EN... |
| 1-1776555-8 | TE Connectiv... | 0.0 $ | 1000 | TERMINAL BLK 18POS 5MM VE... |
| 1776555-3 | TE Connectiv... | 0.0 $ | 1000 | TERMINAL BLK 3POS 5MM VER... |
| 1776906 | Phoenix Cont... | 2.65 $ | 146 | TERM BLOCK HDR 4POS VERT ... |
| 1776553 | Phoenix Cont... | 4.49 $ | 116 | TERM BLOCK HDR 7POS 90DEG... |
| 1776263-3 | TE Connectiv... | 1.41 $ | 49 | TERM BLOCK PLUG 3POS 90DE... |
| 1776274-5 | TE Connectiv... | 0.36 $ | 1000 | TERM BLOCK 5POS SIDE 5.08... |
| 1776161-2 | TE Connectiv... | 0.44 $ | 1000 | TERM BLOCK HDR 2POS VERT ... |
| 1776249-9 | TE Connectiv... | 0.91 $ | 1000 | CONN BARRIER STRIP 3CIRC ... |
| 1776303-3 | TE Connectiv... | 1.29 $ | 1000 | CONN TERM STRIP 3CIRC 0.4... |
| 1776299-6 | TE Connectiv... | 1.36 $ | 1000 | CONN TERM STRIP 6CIRC 0.3... |
| 1776642-1 | TE Connectiv... | 67.1 $ | 1000 | INTERFACE MOD HDR 50POS 1... |
| 1776135-9 | TE Connectiv... | 1.93 $ | 1000 | TERM BLOCK HDR 9POS 90DEG... |
| 1776452-2 | TE Connectiv... | 0.0 $ | 1000 | TERM BLOCK HDR 2POS VERT ... |
| 1776432001 | Weidmuller | 2.0 $ | 1000 | TERM BLOCK HDR 9POS VERT ... |
| 1-1776489-4 | TE Connectiv... | 0.0 $ | 1000 | TERM BLOCK HDR 14POS VERT... |
| 1776280-2 | TE Connectiv... | 0.0 $ | 1000 | TERM BLOCK PLUG 2POS 90DE... |
| 1776293-6 | TE Connectiv... | 4.49 $ | 1131 | CONN TERM STRIP 6CIRC 0.3... |
| 1776296-7 | TE Connectiv... | 4.26 $ | 641 | CONN TERM STRIP 7CIRC 0.3... |
| 1776388 | Phoenix Cont... | 1.06 $ | 38 | TERM BLOCK HDR 3POS VERT ... |
| 1776155-2 | TE Connectiv... | 0.4 $ | 1000 | TERM BLOCK HDR 2POS 90DEG... |
| 1776294-5 | TE Connectiv... | 0.67 $ | 1000 | CONN TERM STRIP 5CIRC 0.3... |
| 1-1776300-2 | TE Connectiv... | 0.0 $ | 1000 | CONN TERM STRIP 12CIRC 0.... |
| 1776715 | Phoenix Cont... | 2.66 $ | 247 | TERM BLOCK HDR 4POS 90DEG... |
| 1776302-8 | TE Connectiv... | 7.22 $ | 47 | CONN TERM STRIP 8CIRC 0.4... |
| 1-1776259-2 | TE Connectiv... | 7.5 $ | 707 | TERM BLOCK 12POS TOP ENT ... |
| 1776153-2 | TE Connectiv... | 0.4 $ | 1000 | TERM BLOCK HDR 2POS VERT ... |
| 1776038-3 | TE Connectiv... | 0.57 $ | 1000 | TERM BLOCK HDR 3POS 90DEG... |
| 1776263-6 | TE Connectiv... | 1.13 $ | 1000 | TERM BLOCK PLUG 6POS 90DE... |
| 1776148-7 | TE Connectiv... | 1.9 $ | 1000 | TERM BLOCK HDR 7POS 90DEG... |
| 1776167-5 | TE Connectiv... | 2.07 $ | 1000 | TERM BLOCK HDR 10POS 5.08... |
| 1776304-8 | TE Connectiv... | 5.5 $ | 1000 | CONN TERM STRIP 8CIRC 0.4... |
| CTX16-17769-R | Eaton | 9.28 $ | 627 | FIXED IND 340UH 5.3A 35 M... |
| 1-177648-5 | TE Connectiv... | 0.83 $ | 618 | CONN HOUSING TAB 5POS KEY... |
| 1-1776146-0 | TE Connectiv... | 2.5 $ | 1000 | TERM BLOCK HDR 10POS VERT... |
| 1-1776260-2 | TE Connectiv... | 6.36 $ | 1000 | TERM BLOCK 12POS TOP ENT ... |
| 1776555-4 | TE Connectiv... | 0.0 $ | 1000 | TERMINAL BLK 4POS 5MM VER... |
TERM BLOCK BARRIERCircuit Connector,
TERM BLOCK BARRIERCircuit Connector,
CONN TERM BLK WW BARR 8POLE8 Circuit 0.2...
CONN TERM BLK EX BARR 2POLE2 Circuit 0.3...
CONN TERM BLK EX MT END 5POLE5 Circuit 0...
CONN TERM BLK EX MT END 2POLE2 Circuit 0...
1776960-4 Datasheet/PDF