2-1546670-4 Allicdata Electronics
Allicdata Part #:

2-1546670-4-ND

Manufacturer Part#:

2-1546670-4

Price: $ 0.00
Product Category:

Connectors, Interconnects

Manufacturer: TE Connectivity AMP Connectors
Short Description: CONN BARRIER STRP 24CIRC 0.437"
More Detail: 24 Circuit 0.437" (11.10mm) Barrier Block Connecto...
DataSheet: 2-1546670-4 datasheet2-1546670-4 Datasheet/PDF
Quantity: 1000
1 +: 0.00000
Stock 1000Can Ship Immediately
$ 0
Specifications
Top Termination: Screws
Material Flammability Rating: UL94 V-0
Material - Insulation: Thermoplastic
Operating Temperature: -40°C ~ 120°C
Mounting Type: Chassis, Panel
Terminal Screw Finish: Nickel
Terminal Screw Material: Steel
Color: Black
Features: Flange
Barrier Type: 2 Wall (Dual)
Bottom Termination: Closed
Series: Buchanan
Wire Gauge: 14-22 AWG
Voltage Rating: 300V
Current Rating: 25A
Number of Rows: 2
Pitch: 0.437" (11.10mm)
Number of Wire Entries: 48
Number of Circuits: 24
Terminal Block Type: Barrier Block
Part Status: Obsolete
Packaging: Bulk 
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Terminal Blocks - Barrier Blocks

2-1546670-4 application field and working principle is a wide-spread and versatile use in a number of industries. This type of terminal block provides an easy way to connect multiple pieces of equipment in a variety of configurations. It also offers a wide variety of connection options such as direct-through, bridge, and star configurations.

Types of Barrier Blocks

The two main types of barrier blocks are external and internal. Both are designed to provide an electrical connection between devices, and both come with a variety of connection options. For example, external barrier blocks are ideal for applications that require multiple inputs and outputs in order to achieve desired results. They are commonly used in automation systems and in industrial control panels.

Internal barrier blocks are typically used for secure, low-voltage applications such as lighting and power. They are often used in conjunction with the external barrier block. The external block allows the connection of multiple devices while the internal blocks provide power, or analysis in order to determine if the connection is functioning correctly.

Uses for 2-1546670-4 Barrier Blocks

Barrier blocks are used in a variety of industries and applications, from furniture outlets to electrical installations. For example, in the furniture industry, barrier blocks are used to connect different components such as lighting, wiring, and casework to the furniture assembly. This helps to ensure that all of the components are properly connected for the smooth operation of the furniture.

Barrier blocks are also used extensively in the electrical and telecommunications industry. These blocks are used to connect different telephone lines and equipment, as well as to provide a secure connection for telephone equipment and wiring. This type of connection ensures that the lines and equipment are supplied with the correct voltage for operation.

In addition, barrier blocks are often used in the automation industry. These blocks provide a secure connection between products such as motors, sensors, and actuators. This type of connection ensures that the products are properly connected for the smooth operation of the automated system.

Barrier blocks are also used in the industrial control field. They provide a secure connection between the industrial control system and its various components. This secure connection ensures that the control system is operating correctly and allows for remote access and control over the system.

Working Principle of 2-1546670-4 Barrier Blocks

Barrier blocks are essentially designed as a secure connection between two or more electrical components. This type of connection works by using several barrier plates which form a barrier between the components. When electricity flows through this barrier, it is diverted into a separate terminal block. This block is then connected to other components in the circuit. There are typically several terminal blocks in an electrical circuit to provide flexibility for connections.

When installing 2-1546670-4 barrier blocks, it is important to ensure that the terminals are properly aligned and the correct size for the application. It is also essential to check the electrical ratings of the components and the power requirements for the block prior to installation. Lastly, it is important to follow the manufacturer’s instructions for installation as improper installation can lead to electrical problems or failure.

Conclusion

2-1546670-4 application field and working principle is a versatile and widely used system in a variety of industries. It allows for secure and efficient connection between multiple components in a variety of configurations. These blocks provide a secure connection and can be installed to ensure the proper voltage and power is supplied for the components in the circuit. As with any electrical connection, it is important to follow manufacturer’s instructions for installation and maintenance.

The specific data is subject to PDF, and the above content is for reference

Latest Products
T34E01406

TERM BLOCK BARRIERCircuit Connector,

T34E01406 Allicdata Electronics
T34E01404

TERM BLOCK BARRIERCircuit Connector,

T34E01404 Allicdata Electronics
CB50420807

CONN TERM BLK WW BARR 8POLE8 Circuit 0.2...

CB50420807 Allicdata Electronics
CB10720207

CONN TERM BLK EX BARR 2POLE2 Circuit 0.3...

CB10720207 Allicdata Electronics
CB10710507

CONN TERM BLK EX MT END 5POLE5 Circuit 0...

CB10710507 Allicdata Electronics
CB10710203

CONN TERM BLK EX MT END 2POLE2 Circuit 0...

CB10710203 Allicdata Electronics