| Allicdata Part #: | 3131-AF1NT-000000-1Y2-5A-ND |
| Manufacturer Part#: |
3131-AF1NT-000000-1Y2-5A |
| Price: | $ 16.32 |
| Product Category: | Circuit Protection |
| Manufacturer: | E-T-A |
| Short Description: | CIR BRKR THRM 5A 250VAC 32VDC |
| More Detail: | N/A |
| DataSheet: | 3131-AF1NT-000000-1Y2-5A Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 10 +: | $ 14.83710 |
| Series: | 3131 |
| Part Status: | Active |
| Lead Free Status / RoHS Status: | -- |
| Breaker Type: | Thermal |
| Moisture Sensitivity Level (MSL): | -- |
| Current Rating: | 5A |
| Voltage Rating - AC: | 250V |
| Voltage Rating - DC: | 32V |
| Number of Poles: | 1 |
| Actuator Type: | Not Included |
| Illumination: | Yellow |
| Illumination Voltage (Nominal): | 10V |
| Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breaker technology has been in use since the early days of electrical engineering. In its most basic form, a circuit breaker is an electrical switch that interrupts the flow of electricity when a fault condition is detected. The 3131-AF1NT-000000-1Y2-5A circuit breaker is a modern variant of the classic design. It is designed to combine the features of two different circuit breaker designs, the arc fault and the ground-fault circuit breaker.
Operational Overview
All circuit breakers are designed to recognize dangerous conditions and shut off the flow of electricity before more damage is done. They are usually either manual or automated. The 3131-AF1NT-000000-1Y2-5A circuit breaker, is an automatic device, meaning that it operates without the need for manual intervention. It is designed to detect both arc faults and ground-faults and to immediately shut off the flow of electricity when a dangerous situation is detected.
Operating Principle
The 3131-AF1NT-000000-1Y2-5A circuit breaker works on the principle of arc detection. When a dangerously high current passes through the circuit, the device disrupts the flow of electricity. This interruption of the current prevents further damage being done to the wiring or other components. It is able to detect both arc faults and ground-faults.
Arc Fault Detection
Arc faults are dangerous because they cause sparks which can be a potential fire hazard. The best way to detect an arc fault is to use a current-sensing device. The 3131-AF1NT-000000-1Y2-5A circuit breaker uses two internal current-sensing devices, one for each kind of fault. These devices measure the level of current going through the circuit and detect any dangerous fluctuations.
Ground Fault Detection
Ground faults can occur when a ground is overloaded or when a wire breaks and makes contact between an electrical component and ground. The 3131-AF1NT-000000-1Y2-5A detects these faults by comparing the current levels at two points in the circuit. If the two current levels are substantially different, then a ground fault has probably occurred.
Trip Settings
The 3131-AF1NT-000000-1Y2-5A circuit breaker has two adjustable trip settings. The first setting is the current level that it is designed to trip when the arc fault is detected. The second setting is the current level that it is designed to trip when a ground fault is detected. Both of these settings can be adjusted, allowing the device to be tailored to the specific conditions and requirements of the circuit that is being protected.
Maintenance
Regular maintenance is essential for the 3131-AF1NT-000000-1Y2-5A circuit breaker to function correctly. This includes checking the device’s trip settings and ensuring that the wiring is intact and secure. If the trip settings have been adjusted, it is important to ensure that the wires are connected correctly and that the device is not being overloaded. Regular inspections of the device should also be conducted to identify any issues that may require repairs.
Conclusion
The 3131-AF1NT-000000-1Y2-5A circuit breaker is a modern variant of the classic design. It is designed to combine the features of two different circuit breaker designs, the arc fault and the ground-fault circuit breaker. It works on the principle of arc detection, using two internal current-sensing devices, and it is able to detect both arc faults and ground-faults. It has two adjustable trip settings, allowing it to be tailored to the specific requirements of the circuit being protected. Regular maintenance is essential for the device to remain in good working order.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| 3131-AF1PT-000000-000-2.5A | E-T-A | 31.49 $ | 1000 | CIRC BRKR THRM |
| BU-3131-A-12-2 | Mueller Elec... | 4.82 $ | 1000 | TEST LEAD MINI-ALLIGATOR1... |
| 3131 BK005 | Alpha Wire | 0.0 $ | 1000 | HOOK-UP STRND 16AWG BLACK... |
| IEGS1-1REC4-31314-15-V | Sensata-Airp... | 28.95 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
| 09-50-3131 | Molex Connec... | 0.52 $ | 1189 | CONN RECEPT 13POS .156 W/... |
| 3131 GY001 | Alpha Wire | 0.0 $ | 1000 | HOOK-UP 16AWG GRN/YEL 100... |
| 3131-AF1HT-000000-3Y2-5A | E-T-A | 34.97 $ | 1000 | CIRC BRKR THRM |
| 3131A F2V1000 | Belden Inc. | 0.69 $ | 1000 | COAX 18AWG QUAD SHLD 75 O... |
| 31316 | Parallax Inc... | 0.0 $ | 1000 | BOARD AUDIO PLAYER AP-16+... |
| IELK1111-31311-2-V | Sensata-Airp... | 241.83 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| BU-3131-A-48-2 | Mueller Elec... | 4.92 $ | 1000 | TEST LEAD MINI-ALLIGATOR4... |
| 3131-AF1HT-000000-3T2-1A | E-T-A | 34.97 $ | 1000 | CIRC BRKR THRM |
| 3131141 | Phoenix Cont... | 0.81 $ | 1000 | JUMPER FOR MODULAR TERM B... |
| 3131-AF1PT-000000-1T2-8A | E-T-A | 16.32 $ | 1000 | CIR BRKR THRM 8A 250VAC 3... |
| 91901-31311LF | Amphenol FCI | 0.97 $ | 1000 | CONN HEADER 11POS 1MM VER... |
| 3131441 TN001 | Alpha Wire | 0.69 $ | 1000 | CBL 1COND 14AWG 600V TAN ... |
| 313173-2 | TE Connectiv... | 466.74 $ | 1000 | INDENTER INSULATION UPPER |
| 3131-AF1PT-000000-1T3-10A | E-T-A | 34.97 $ | 1000 | CIRC BRKR THRM |
| 3131-AF1NT-000000-1Y2-5A | E-T-A | 16.32 $ | 1000 | CIR BRKR THRM 5A 250VAC 3... |
| 3131-DF1NQ-000000-2Y2-20A | E-T-A | 16.3 $ | 1000 | CIRCUIT BREAKER THRM 20A ... |
| 3131-AF1PT-000000-3Y2-20A | E-T-A | 16.32 $ | 1000 | CIR BRKR THRM 20A 250VAC ... |
| 3131-BF1NQ-000000-2T3-20A | E-T-A | 16.32 $ | 1000 | CIRCUIT BREAKER THRM 20A ... |
| 3131-AF1NT-000000-1T2-15A | E-T-A | 34.97 $ | 1000 | CIRC BRKR THRM |
| 313196-3 | TE Connectiv... | 202.76 $ | 1000 | TOOL KIT, EXPANSION, SUBA... |
| 3131-AF1PT-000000-000-3A | E-T-A | 14.0 $ | 1000 | CIR BRKR THRM 3A 250VAC 3... |
| 3131-AF1HT-000000-1Y2-2.5A | E-T-A | 16.32 $ | 1000 | CIR BRKR THRM 2.5A 250VAC... |
| 3131-CF1PT-000000-3Y2-20A | E-T-A | 34.99 $ | 1000 | CIRC BRKR THRM |
| 3131-AF1PT-000000-1T3-16A | E-T-A | 16.3 $ | 1000 | CIR BRKR THRM 16A 250VAC ... |
| 3131-BF1NQ-000000-2T2-20A | E-T-A | 16.32 $ | 1000 | CIRCUIT BREAKER THRM 20A ... |
| 313100001 | C&K | 86.37 $ | 1000 | SWITCH THUMB BCD 0.1A 120... |
| 3131-AF1PT-000000-000-16A | E-T-A | 14.0 $ | 1000 | CIR BRKR THRM 16A 250VAC ... |
| BU-3131-A-60-0 | Mueller Elec... | 4.92 $ | 1000 | TEST LEAD MINI-ALLIGATOR6... |
| 3131816 TN003 | Alpha Wire | 0.0 $ | 1000 | CBL 1COND 18AWG 600V TAN ... |
| 3131-AF1PT-000000-000-15A | E-T-A | 14.0 $ | 1000 | CIR BRKR THRM 15A 240VAC ... |
| 3131-AF1PT-000000-1Y6-20A | E-T-A | 16.3 $ | 1000 | CIR BRKR THRM 20A 250VAC ... |
| 3131-AF1HT-000000-1Y2-0.3A | E-T-A | 18.56 $ | 1000 | CIR BRKR THRM 300MA 250VA... |
| 3131-AF1NT-000000-1Y2-2A | E-T-A | 19.25 $ | 1000 | CIR BRKR THRM 2A 250VAC 3... |
| 10124017-3131121LF | Amphenol FCI | 1.11 $ | 1000 | CONAN PLUG |
| 3131-AF1PT-000000-1Y2-2A | E-T-A | 19.25 $ | 1000 | CIR BRKR THRM 2A 250VAC 3... |
| 3131-AF1PT-000000-000-12A | E-T-A | 14.0 $ | 1000 | CIR BRKR THRM 12A 250VAC ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A
3131-AF1NT-000000-1Y2-5A Datasheet/PDF