Allicdata Part #: | 3414.0119.26.M-ND |
Manufacturer Part#: |
3414.0119.26.M |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Schurter Inc. |
Short Description: | FUSE BOARD MNT 0402 |
More Detail: | N/A |
DataSheet: | 3414.0119.26.M Datasheet/PDF |
Quantity: | 1000 |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
1 +: | 0.00000 |
Package / Case: | 0402 (1005 Metric) |
DC Cold Resistance: | 0.03 Ohms |
Size / Dimension: | 0.040" L x 0.020" W x 0.019" H (1.00mm x 0.50mm x 0.48mm) |
Color: | -- |
Operating Temperature: | -55°C ~ 90°C |
Approvals: | cURus |
Melting I²t: | 0.1 |
Breaking Capacity @ Rated Voltage: | 35A |
Mounting Type: | Surface Mount |
Series: | USF 0402 |
Response Time: | Fast |
Voltage Rating - DC: | 32V |
Current Rating: | 2A |
Moisture Sensitivity Level (MSL): | -- |
Fuse Type: | Board Mount (Cartridge Style Excluded) |
Lead Free Status / RoHS Status: | -- |
Part Status: | Obsolete |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
The 3414.0119.26.M product is a fuse which is used in various applications, from general industrial, automotive, telecommunications, or power distribution to even very specific applications such as automotive circuit protection. Fuses ensure that circuit protection does not degrade over time and guard against the risk of fire arising from short-circuits and overloads.
The 3414.0119.26.M fuse is used mainly in the automotive industry where it operates in both AC and DC circuits. It is also typically used for medium voltage applications in industrial, telecommunications, and power distribution sectors. Generally, fuses should be used when a load device needs to be protected against short circuit conditions or when a high overload condition requires current limiting to prevent damage to the power supply. Due to its current rating and breaking capacity, it can be used in a range of applications from domestic consumer units to medium sized domestic and light industrial installations. This fuse type is designed for use in up to 3-phase AC applications with two poles.
The 3414.0119.26.M operates based on the principle of melting metal when the current through exceeds the rated current. The meltable metal in the fuse is designed to melt in a certain amount of time, when the current passing through the fuse is more than the rated current. This action of melting serves both to open the circuit, cutting off the power supply to the device and to prevent the further flow of current. In case of a short-circuit, or an overload, the metal melts down quickly, thereby restricting the flow of current in order to protect the circuitry. Apart from these, the 3414.0119.26.M also features a vibration-resistant design, which aids to reduce the chances for false tripping. Additionally, the solderless pressure connection allows for easy and secure installation, accelerates the wiring process and ensures long-lasting connections.
When looking for the right fuse for a specific application, it is important to understand the factors that influence fuse selection. The following criteria should be taken into consideration: the amount of current that could pass through the fuse, the voltage rating, the interrupting rating and the response time. In addition, factors such as physical size, mounting type and pluggability should be considered as well. When it comes to the 3414.0119.26.M, these factors are all met, offering reliability and efficiency requested for a variety of applications.
The 3414.0119.26.M is a specialized fuse designed for various applications, including automotive, telecommunications, and power distribution. It has a current rating and breaking capacity suitable for domestic consumer units to medium size industrial installations, and it is designed for use in up to three-phase AC applications with two poles. The working principle of the 3414.0119.26.M is to melt metal when the current through it exceeds the rated current limit, thereby cutting off the power supply and protecting the circuitry. In order to get the right fuse for a specific application, it is important to understand the factors influencing fuse selection. The 3414.0119.26.M meets various factors such as voltage rating, response time, and physical size.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
IULHK11-34144-1 | Sensata-Airp... | 123.93 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IALN11-34148-2 | Sensata-Airp... | 133.04 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
3414.0112.24 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 375MA 32VD... |
3414.0113.24 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 500MA 32VD... |
3414.0121.24 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MOUNT 3A 32VDC... |
3414.0123.24 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MOUNT 4A 32VDC... |
3414.0124.24 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MOUNT 5A 24VDC... |
3414.0113.22 | Schurter Inc... | 0.16 $ | 1000 | FUSE BOARD MNT 500MA 32VD... |
3414.0114.22 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 750MA 32VD... |
3414.0115.22 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MOUNT 1A 32VDC... |
3414.0117.22 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MOUNT 1.5A 32V... |
3414.0119.22 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MOUNT 2A 32VDC... |
3414.0124.22 | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MOUNT 5A 24VDC... |
3414.0112.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0113.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0114.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0115.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0117.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0119.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0120.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0121.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0123.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0124.26.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0112.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0112.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0113.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0113.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0114.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0114.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0115.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0115.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0117.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0117.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0119.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0119.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0120.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0120.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0121.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0121.24.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
3414.0123.22.M | Schurter Inc... | 0.0 $ | 1000 | FUSE BOARD MNT 0402 |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL