![39708000000 Allicdata Electronics](https://files.allicdata.com/upload/common/default.jpg)
Allicdata Part #: | 39708000000-ND |
Manufacturer Part#: |
39708000000 |
Price: | $ 0.26 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | FUSE BOARD MNT 800MA 125VAC RAD |
More Detail: | N/A |
DataSheet: | ![]() |
Quantity: | 1000 |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
1400 +: | $ 0.23020 |
Package / Case: | Radial, Box |
DC Cold Resistance: | 0.1616 Ohms |
Size / Dimension: | 0.335" L x 0.157" W x 0.315" H (8.50mm x 4.00mm x 8.00mm) |
Color: | -- |
Operating Temperature: | -40°C ~ 85°C |
Approvals: | cUL, UL |
Melting I²t: | 2.4 |
Breaking Capacity @ Rated Voltage: | 50A |
Mounting Type: | Through Hole |
Series: | TE5® 397 |
Response Time: | Slow |
Voltage Rating - AC: | 125V |
Current Rating: | 800mA |
Fuse Type: | Board Mount (Cartridge Style Excluded) |
Moisture Sensitivity Level (MSL): | -- |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Packaging: | Tape & Box (TB) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses are the most commonly used over-current protection device in low and medium-voltage electrical systems. Fuses have been in use since the 19th century and nowadays they are the most reliable and cost-effective form of protection to prevent damage from over-currents and short circuits. The 39708000000 application field and working principles of fuses are described in this article.
Types and Working Principle of Fuses:
Fuses are divided into two main types, namely Type 1 and Type 2. Type 1 Fuses are the most commonly used for over-current protection in medium-voltage power distribution systems, and they are designed to protect the electrical components of the system from over-currents and short circuits. Type 1 Fuses are made of a metal sheath and two fusible elements, i.e., a current limiting resistor and a trip coil. When a current exceeding the rated current flows through the fuse, the current-limiting resistor causes a rapid rise in temperature, which in turn causes the fusible elements to melt. This results in the opening of the trip coil, which cuts off the current flow and thereby prevents the damage due to a short circuit.
Type 2 Fuses are used for over-current protection in low-voltage systems such as industrial control systems, domestic equipment, etc. These fuses are made of a ceramic tube containing a copper wire element. When the current flowing through the fuse exceeds the rated current, the temperature of the element increases rapidly and fuses it away from the ceramic tube. This opens the circuit, preventing the damage caused by a short circuit.
Advantages of Fuses:
Fuses offer numerous advantages over other types of over-current protection devices. They are relatively low cost, easy to install, and most importantly they are fast in operation, and hence they can protect against sudden surge in currents faster than other protective devices. Another advantage of fuses is that they are non-directional, i.e., they can disconnect the circuit in both over-current and under-current conditions. They also require no maintenance and are safe to use, due to their thermal and non-conductive characteristics.
39708000000 Application Field and Working Principle of Fuses :
The 39708000000 application field of fuses is mainly in the protection of electrical and electronic circuits. They are widely used in medium and low voltage power systems, industrial control systems, domestic appliances, data centers, and other applications.
The working principle of a fuse is based on its ability to limit and interrupt the excessive current flow. When a current exceeding the rated current and time range flows through the fuse, the temperature of the element inside the fuse increases rapidly due to the Joule heating effect. This in turn increases the melting point of the element and causes it to melt. When this happens, the contacts of the fuse become disconnected and the circuit will be opened, thus breaking the current flow and preventing the damage due to an overload or a short circuit.
Safety Considerations:
Fuses must be used with caution, as they can be dangerous when used incorrectly. Before installing a fuse, the user must ensure that the fuse corresponds with the system and current requirements. They must also be replaced as soon as possible, as they can be damaged over time due to the high current ratings they carry. Additionally, whenever a fuse blows, the user should always check the circuit to identify the cause of the problem before replacing the fuse, as not doing this could put the system at risk for further damage.
In conclusion, fuses are an effective and safe means of protecting against over-currents and short circuits. Their 39708000000 application field and working principles ensure that they are an essential component in all power systems. Care should be taken while installing and using them, as misuse can lead to severe damage to the system.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
IEGBX1-1REC5-39702-16-V | Sensata-Airp... | 50.3 $ | 1000 | CIR BRKR MAG-HYDR ROCKER ... |
IEGBX1-1REC5-39702-25-V | Sensata-Airp... | 50.3 $ | 1000 | CIR BRKR MAG-HYDR ROCKER ... |
IEGBX1-1REC5-39702-30-V | Sensata-Airp... | 50.3 $ | 1000 | CIR BRKR MAG-HYDR ROCKER ... |
IEGBX1-1REC5-39702-8-V | Sensata-Airp... | 50.3 $ | 1000 | CIR BRKR MAG-HYDR ROCKER ... |
IUGNF66-39709-439 | Sensata-Airp... | 103.24 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-440 | Sensata-Airp... | 103.67 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-441 | Sensata-Airp... | 103.67 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-486 | Sensata-Airp... | 103.67 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-492 | Sensata-Airp... | 103.67 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-493 | Sensata-Airp... | 103.67 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-497 | Sensata-Airp... | 103.67 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-498 | Sensata-Airp... | 103.67 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-442 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-541 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-542 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-543 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-544 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-545 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-546 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IUGNF66-39709-547 | Sensata-Airp... | 103.67 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IEGS1-39701-10-V | Sensata-Airp... | 38.51 $ | 1000 | CIR BRKR MAG-HYDR LEVER 1... |
IUGNF66-39709-540 | Sensata-Airp... | 112.76 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-549 | Sensata-Airp... | 112.76 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IUGNF66-39709-539 | Sensata-Airp... | 112.76 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
209-3-39703-1 | Sensata-Airp... | 193.26 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
397004-01 | Qualtek | 4.24 $ | 300 | CORD 16AWG JIS 8303 TO CB... |
397003-01 | Qualtek | 5.24 $ | 194 | CORD 16AWG 8303-IEC320-C1... |
397005-01 | Qualtek | 5.45 $ | 295 | CORD 16AWG JIS 8303 TO CB... |
397002-01 | Qualtek | 5.82 $ | 648 | POWER CORD 12A 2.5M8.20' ... |
39703500000 | Littelfuse I... | 0.26 $ | 1000 | FUSE BOARD MNT 350MA 125V... |
39705000000 | Littelfuse I... | 0.26 $ | 1000 | FUSE BOARD MNT 500MA 125V... |
39708000000 | Littelfuse I... | 0.26 $ | 1000 | FUSE BOARD MNT 800MA 125V... |
39703500440 | Littelfuse I... | 0.28 $ | 1000 | FUSE BOARD MNT 350MA 125V... |
39705000440 | Littelfuse I... | 0.28 $ | 1000 | FUSE BOARD MNT 500MA 125V... |
39708000440 | Littelfuse I... | 0.28 $ | 1000 | FUSE BOARD MNT 800MA 125V... |
IULZXK21-39708-20 | Sensata-Airp... | 140.32 $ | 1000 | CIR BRKR MAG-HYDR ROCKER |
UPGH11-3970-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
70156-3970 | Omron Automa... | 2.08 $ | 1000 | SYSTEM |
39700 | Desco | 0.0 $ | 1000 | SHORT PARTITION 457-SP |
39702 | Desco | 0.0 $ | 1000 | SHORT PARTITION 458-SP |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
![3404.0011.11 Allicdata Electronics](https://files.allicdata.com/upload/common/default.jpg)
FUSE BOARD MNT 3.15A 125VAC/VDC
![2060.0048.11 Allicdata Electronics](https://files.allicdata.com/upload/common/default.jpg)
FUSE BOARD MNT 350MA 125VAC/VDC
![2060.0043.11 Allicdata Electronics](https://files.allicdata.com/upload/common/default.jpg)
FUSE BRD MNT 2.5A 125VAC/VDC SMD
![2060.0013.11 Allicdata Electronics](https://files.allicdata.com/upload/common/default.jpg)
FUSE BRD MNT 1.6A 125VAC/VDC SMD
![2060.0011.11 Allicdata Electronics](https://files.allicdata.com/upload/common/default.jpg)
FUSE BOARD MNT 1A 250VAC RADIAL
![2040.0715 Allicdata Electronics](https://files.allicdata.com/upload/common/default.jpg)