Allicdata Part #: | 3AP12-ND |
Manufacturer Part#: |
3AP 12 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | |
Short Description: | FUSE GLASS 12A 125VAC 3AB 3AG |
More Detail: | N/A |
DataSheet: | 3AP 12 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Contains lead / RoHS non-compliant |
1 +: | 0.00000 |
Package / Case: | 3AB, 3AG, 1/4" x 1-1/4" (Axial) |
DC Cold Resistance: | 0.007 Ohms |
Size / Dimension: | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) |
Color: | -- |
Operating Temperature: | -55°C ~ 125°C |
Approvals: | CE, CSA, PSE, UL |
Melting I²t: | 501 |
Breaking Capacity @ Rated Voltage: | 10kA |
Mounting Type: | Through Hole |
Series: | 3AP |
Response Time: | Fast |
Voltage Rating - AC: | 125V |
Current Rating: | 12A |
Fuse Type: | Cartridge, Glass |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses are safety devices used to protect electrical circuits, equipment, and components against dangerous overloads and short circuits. They can be made in either re-settable or non-resettable varieties. Fuses have been extensively used in various applications due to their reliability and ease of maintenance. Their primary use is to provide overcurrent protection for high-voltage systems. Fuses are available in a wide variety of shapes, sizes, and materials.
3AP 12 application field and working principle refers to the application and operation of 3AP 12 fuses. 3AP 12 is a type of voltage-dependent overcurrent circuit breaker, designed to be used in low-voltage circuits. This fuse type operates on the principle of detecting an overload condition and automatically disconnecting the circuit when the overload exceeds the specified current limit.
In order to operate correctly, 3AP 12 fuses must be installed with the correct fuse size and must be properly rated for the voltage they are protecting. The device must also be adequately rated for the type and amount of current it will be carrying. The fuse must also be secured in place firmly and properly. When choosing a 3AP 12 fuse, it is important to select a fuse that is rated for the current and voltage supplied by the circuit it is protecting.
The working principle of 3AP 12 fuses relies on the heat generated by the overload current flowing through the fuse element. When the current exceeds the rated current, the element melts and the circuit is disconnected. This allows the heat to dissipate and the overload condition to be cleared. This is commonly referred to as “thermal disconnection”.
3AP 12 fuses are typically used in home appliances such as air conditioners, refrigerators, washing machines, dryers, and dishwashers. They are also commonly found in industrial equipment, such as paper processing machines, pumps, transformers, and other equipment. In addition, 3AP 12 fuses are used in automotive, marine, and aviation circuit protection applications.
The 3AP 12 fuses provide a reliable and safe method of circuit protection from dangerous overload conditions. They are also relatively easy to install and maintain. Proper installation and selection of the correct fuse size are critical in ensuring the safety of the circuit and its components.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
3AP 100 | 0.0 $ | 1000 | FUSE GLASS 100MA 250VAC 3... | |
3AP 125 | 0.0 $ | 1000 | FUSE GLASS 125MA 250VAC 3... | |
3AP 160 | 0.0 $ | 1000 | FUSE GLASS 160MA 250VAC 3... | |
3AP 200 | 0.0 $ | 1000 | FUSE GLASS 200MA 250VAC 3... | |
3AP 250 | 0.0 $ | 1000 | FUSE GLASS 250MA 250VAC 3... | |
3AP 300 | 0.0 $ | 1000 | FUSE GLASS 300MA 250VAC 3... | |
3AP 375 | 0.0 $ | 1000 | FUSE GLASS 375MA 250VAC 3... | |
3AP 500 | 0.0 $ | 1000 | FUSE GLASS 500MA 250VAC 3... | |
3AP 750 | 0.0 $ | 1000 | FUSE GLASS 750MA 250VAC 3... | |
3AP 1 | 0.0 $ | 1000 | FUSE GLASS 1A 250VAC 3AB ... | |
3AP 1.25 | 0.0 $ | 1000 | FUSE GLASS 1.25A 250VAC 3... | |
3AP 1.6 | 0.0 $ | 1000 | FUSE GLASS 1.6A 250VAC 3A... | |
3AP 2 | 0.0 $ | 1000 | FUSE GLASS 2A 250VAC 3AB ... | |
3AP 2.5 | 0.0 $ | 1000 | FUSE GLASS 2.5A 250VAC 3A... | |
3AP 3 | 0.0 $ | 1000 | FUSE GLASS 3A 250VAC 3AB ... | |
3AP 3.5 | 0.0 $ | 1000 | FUSE GLASS 3.5A 250VAC 3A... | |
3AP 4 | 0.0 $ | 1000 | FUSE GLASS 4A 250VAC 3AB ... | |
3AP 5 | 0.0 $ | 1000 | FUSE GLASS 5A 250VAC 3AB ... | |
3AP 6 | 0.0 $ | 1000 | FUSE GLASS 6A 250VAC 3AB ... | |
3AP 7 | 0.0 $ | 1000 | FUSE GLASS 7A 250VAC 3AB ... | |
3AP 8 | 0.0 $ | 1000 | FUSE GLASS 8A 250VAC 3AB ... | |
3AP 10 | 0.0 $ | 1000 | FUSE GLASS 10A 250VAC 3AB... | |
3AP 12 | 0.0 $ | 1000 | FUSE GLASS 12A 125VAC 3AB... | |
3AP 15 | 0.0 $ | 1000 | FUSE GLASS 15A 125VAC 3AB... | |
APD-3AP-K2 | ITT Cannon, ... | 4.63 $ | 156 | CONN RCPT HSNG MALE 4POS ... |
APD-3AP19S | ITT Cannon, ... | 10.3 $ | 1000 | CONN RCPT HSNG MALE 19POS... |
3AP 7-R | 0.14 $ | 1000 | FUSE GLASS 7A 250VAC 3AB ... | |
3AP 160-R | 0.14 $ | 1000 | FUSE GLASS 160MA 250VAC 3... | |
3AP 10-R | 0.14 $ | 1000 | FUSE GLASS 10A 250VAC 3AB... | |
3AP 125-R | 0.14 $ | 1000 | FUSE GLASS 125MA 250VAC 3... | |
3AP 750-R | 0.14 $ | 1000 | FUSE GLASS 750MA 250VAC 3... | |
3AP 300-R | 0.14 $ | 1000 | FUSE GLASS 300MA 250VAC 3... | |
3AP 3-R | 0.14 $ | 1000 | FUSE GLASS 3A 250VAC 3AB ... | |
3AP 8-R | 0.14 $ | 1000 | FUSE GLASS 8A 250VAC 3AB ... | |
3AP 2.5-R | 0.14 $ | 1000 | FUSE GLASS 2.5A 250VAC 3A... | |
3AP 2-R | 0.14 $ | 1000 | FUSE GLASS 2A 250VAC 3AB ... | |
3AP 200-R | 0.14 $ | 1000 | FUSE GLASS 200MA 250VAC 3... | |
3AP 500-R | 0.14 $ | 1000 | FUSE GLASS 500MA 250VAC 3... | |
3AP 250-R | 0.14 $ | 1000 | FUSE GLASS 250MA 250VAC 3... | |
3AP 375-R | 0.14 $ | 1000 | FUSE GLASS 375MA 250VAC 3... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL