Allicdata Part #: | 3AP8-ND |
Manufacturer Part#: |
3AP 8 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | |
Short Description: | FUSE GLASS 8A 250VAC 3AB 3AG |
More Detail: | N/A |
DataSheet: | 3AP 8 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Contains lead / RoHS non-compliant |
1 +: | 0.00000 |
Package / Case: | 3AB, 3AG, 1/4" x 1-1/4" (Axial) |
DC Cold Resistance: | 0.012 Ohms |
Size / Dimension: | 0.272" Dia x 1.280" L (6.90mm x 32.50mm) |
Color: | -- |
Operating Temperature: | -55°C ~ 125°C |
Approvals: | CE, CSA, PSE, UL |
Melting I²t: | 184 |
Breaking Capacity @ Rated Voltage: | 200A |
Mounting Type: | Through Hole |
Series: | 3AP |
Response Time: | Fast |
Voltage Rating - AC: | 250V |
Current Rating: | 8A |
Fuse Type: | Cartridge, Glass |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses are an important component of electrical systems, as they are designed to prevent overcurrent conditions. 3AP 8 fuses are among the most common types of fuses, and are used in a variety of applications. This article will discuss the different application fields and working principles of 3AP 8 fuses.
The first application field for 3AP 8 fuses is in the protection of power distribution systems. These fuses are typically used in the main switchboards of large buildings, industrial plants, and electrical substations. They are used to protect the circuits from excessive current and to prevent dangerous short-circuit conditions from occurring in the system. 3AP 8 fuses can also be used in residential circuits where the current load is relatively low. They are designed to protect these circuits against overloads and short-circuits.
A second application field for 3AP 8 fuses is in the protection of motors. These fuses are used for the protection of motors and other equipment that can produce excessive amounts of current during a fault condition. They are designed to open the circuit when the current exceeds the rating of the fuse, thereby preventing damage to the motor and the rest of the system.
The third application field for 3AP 8 fuses is in the protection of electronic equipment. These fuses are used for the protection of computer systems, control systems, and other electronic equipment. They are designed to open the circuit and disconnect the equipment from the supply when the current exceeds the specified rating. This helps to protect the equipment from damage due to excessive current.
The fourth application field for 3AP 8 fuses is in the protection of telecommunications systems. These fuses are typically used to protect telephone and radio systems from high currents. They are designed to automatically open the circuit when the current exceeds the specified rating.
Finally, 3AP 8 fuses are also used in the protection of power transformers. These fuses are used to protect the transformers from overcurrents that can cause damage to the transformer’s insulation. They are designed to open the circuit when the current exceeds the rating of the fuse.
The 3AP 8 fuse works by melting in an overcurrent situation. This melting occurs when the current passing through the fuse exceeds its rating. This causes a large amount of heat to be generated, which melts the fuse and opens the circuit. This prevents further current from passing through the circuit, thus protecting the system or equipment from damage.
In conclusion, 3AP 8 fuses are a type of fuse used for the protection of a variety of electrical systems and equipment. They are designed to open the circuit in situations of excessive current, thereby protecting the system or equipment from damage. The working principle of these fuses involves the melting of the fuse when an overcurrent situation occurs, thus opening the circuit and preventing further current from passing through it.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
3AP 100 | 0.0 $ | 1000 | FUSE GLASS 100MA 250VAC 3... | |
3AP 125 | 0.0 $ | 1000 | FUSE GLASS 125MA 250VAC 3... | |
3AP 160 | 0.0 $ | 1000 | FUSE GLASS 160MA 250VAC 3... | |
3AP 200 | 0.0 $ | 1000 | FUSE GLASS 200MA 250VAC 3... | |
3AP 250 | 0.0 $ | 1000 | FUSE GLASS 250MA 250VAC 3... | |
3AP 300 | 0.0 $ | 1000 | FUSE GLASS 300MA 250VAC 3... | |
3AP 375 | 0.0 $ | 1000 | FUSE GLASS 375MA 250VAC 3... | |
3AP 500 | 0.0 $ | 1000 | FUSE GLASS 500MA 250VAC 3... | |
3AP 750 | 0.0 $ | 1000 | FUSE GLASS 750MA 250VAC 3... | |
3AP 1 | 0.0 $ | 1000 | FUSE GLASS 1A 250VAC 3AB ... | |
3AP 1.25 | 0.0 $ | 1000 | FUSE GLASS 1.25A 250VAC 3... | |
3AP 1.6 | 0.0 $ | 1000 | FUSE GLASS 1.6A 250VAC 3A... | |
3AP 2 | 0.0 $ | 1000 | FUSE GLASS 2A 250VAC 3AB ... | |
3AP 2.5 | 0.0 $ | 1000 | FUSE GLASS 2.5A 250VAC 3A... | |
3AP 3 | 0.0 $ | 1000 | FUSE GLASS 3A 250VAC 3AB ... | |
3AP 3.5 | 0.0 $ | 1000 | FUSE GLASS 3.5A 250VAC 3A... | |
3AP 4 | 0.0 $ | 1000 | FUSE GLASS 4A 250VAC 3AB ... | |
3AP 5 | 0.0 $ | 1000 | FUSE GLASS 5A 250VAC 3AB ... | |
3AP 6 | 0.0 $ | 1000 | FUSE GLASS 6A 250VAC 3AB ... | |
3AP 7 | 0.0 $ | 1000 | FUSE GLASS 7A 250VAC 3AB ... | |
3AP 8 | 0.0 $ | 1000 | FUSE GLASS 8A 250VAC 3AB ... | |
3AP 10 | 0.0 $ | 1000 | FUSE GLASS 10A 250VAC 3AB... | |
3AP 12 | 0.0 $ | 1000 | FUSE GLASS 12A 125VAC 3AB... | |
3AP 15 | 0.0 $ | 1000 | FUSE GLASS 15A 125VAC 3AB... | |
APD-3AP-K2 | ITT Cannon, ... | 4.63 $ | 156 | CONN RCPT HSNG MALE 4POS ... |
APD-3AP19S | ITT Cannon, ... | 10.3 $ | 1000 | CONN RCPT HSNG MALE 19POS... |
3AP 7-R | 0.14 $ | 1000 | FUSE GLASS 7A 250VAC 3AB ... | |
3AP 160-R | 0.14 $ | 1000 | FUSE GLASS 160MA 250VAC 3... | |
3AP 10-R | 0.14 $ | 1000 | FUSE GLASS 10A 250VAC 3AB... | |
3AP 125-R | 0.14 $ | 1000 | FUSE GLASS 125MA 250VAC 3... | |
3AP 750-R | 0.14 $ | 1000 | FUSE GLASS 750MA 250VAC 3... | |
3AP 300-R | 0.14 $ | 1000 | FUSE GLASS 300MA 250VAC 3... | |
3AP 3-R | 0.14 $ | 1000 | FUSE GLASS 3A 250VAC 3AB ... | |
3AP 8-R | 0.14 $ | 1000 | FUSE GLASS 8A 250VAC 3AB ... | |
3AP 2.5-R | 0.14 $ | 1000 | FUSE GLASS 2.5A 250VAC 3A... | |
3AP 2-R | 0.14 $ | 1000 | FUSE GLASS 2A 250VAC 3AB ... | |
3AP 200-R | 0.14 $ | 1000 | FUSE GLASS 200MA 250VAC 3... | |
3AP 500-R | 0.14 $ | 1000 | FUSE GLASS 500MA 250VAC 3... | |
3AP 250-R | 0.14 $ | 1000 | FUSE GLASS 250MA 250VAC 3... | |
3AP 375-R | 0.14 $ | 1000 | FUSE GLASS 375MA 250VAC 3... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL