Allicdata Part #: | 42411000101-ND |
Manufacturer Part#: |
42411000101 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | FUSE BOARD MNT 1A 125VAC/VDC SMD |
More Detail: | N/A |
DataSheet: | 42411000101 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Contains lead / RoHS non-compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | 424 |
Packaging: | Tape & Reel (TR) |
Lead Free Status / RoHS Status: | -- |
Part Status: | Obsolete |
Moisture Sensitivity Level (MSL): | -- |
Fuse Type: | Board Mount (Cartridge Style Excluded) |
Current Rating: | 1A |
Voltage Rating - AC: | 125V |
Voltage Rating - DC: | 125V |
Response Time: | Fast |
Package / Case: | SMD w/Holder |
Mounting Type: | Holder |
Breaking Capacity @ Rated Voltage: | 50A |
Melting I²t: | 0.42 |
Approvals: | cULus |
Operating Temperature: | -55°C ~ 125°C |
Color: | -- |
Size / Dimension: | 0.394" L x 0.197" W x 0.146" H (10.00mm x 5.00mm x 3.70mm) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses are amongst the most critical elements of a new technology or system. 4-2-4-1-1-0-0-1-0-1 Fuses are arguably the most important safety device, as these devices protect individuals, property, and functions from potentially dangerous intensity or current flows. Fuses are designed to open when too much current is drawn from a circuit, which in turn prevents damage to electrical equipment.
4-2-4-1-1-0-0-1-0-1 Fuses are found in a plethora of devices, ranging from home appliances to motor vehicles to industrial equipment and systems. In each application, the fuse\'s purpose remains the same, to protect against potentially damaging degrees of current. But in terms of application, 4-2-4-1-1-0-0-1-0-1 Fuses can be grouped in general and specific fields depending on the capabilities and characteristics of the fuse s in question.
Generally speaking, there are two major application fields for 4-2-4-1-1-0-0-1-0-1 Fuses: overcurrent protection and electric isolation. Overcurrent protection Fuses are used to protect operating components and circuits against excess current, while electric isolation Fuses are used to protect adjacent or opposing circuits from each other. As such, understanding the working principles of both overcurrent protection and electric isolation Fuses is critical for ensuring the appropriate fuse is utilized in any given system.
Overcurrent Protection Fuses
In terms of overcurrent protection, the working principle behind 4-2-4-1-1-0-0-1-0-1 Fuses is to protect a system against an excessive, or ‘overcurrent’ flow. In these fuse-protected systems, the circuit will typically remain closed until it begins to draw too much current, at which point the fuse ‘opens’ or ‘blows’, preventing further current from flowing and thus saving the system from potential damage. It is important to note that the rated current of the fuse must be correctly selected and never exceeded, as exceeding the rated current can nullify the fuse’s protective mechanism.
Electric Isolation Fuses
Unlike overcurrent protection Fuses, which are designed to prevent damage from an excessive current flow, electric isolation Fuses serve to prevent the transfer of current from one circuit to another. In these applications, the 4-2-4-1-1-0-0-1-0-1 Fuses are designed with elements that ‘short-circuit’ when the predetermined clearing current is exceeded; in doing so, the fuse creates a break in the circuit thus preventing the current transfer. This type of fuse is commonly used in household appliances and industrial systems to protect adjacent or opposing circuits from each other.
Conclusion
The 4-2-4-1-1-0-0-1-0-1 Fuse is a safety device designed to protect a system in the event of an excess current flow. When utilized correctly, these devices can ensure safe operation of a wide range of applications. 4-2-4-1-1-0-0-1-0-1 Fuses are available in two major application fields; overcurrent protection Fuses are designed to prevent damage to a system should it draw an excessive current, while electric isolation Fuses are used to ensure that one circuit does not transfer its current to another. Understanding the working principle behind both of these fuse types is key to selecting the appropriate fuse for any application and ensuring the safety of those utilizing any given system.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
42410-8314 | Molex Connec... | 1.01 $ | 1702 | CONN MOD JACK 8P8C VERT U... |
4241 | Keystone Ele... | 0.0 $ | 1000 | BREADBOARD P PATTERN .042... |
1-424156-2 | TE Connectiv... | 1.29 $ | 1000 | CONT SPG L HDContact Gold... |
1-424155-2 | TE Connectiv... | 1.6 $ | 1000 | CONN CONTACT SPRING .031X... |
424156-8 | TE Connectiv... | 1.86 $ | 1000 | CONT SPG L HDContact Gold... |
424155-8 | TE Connectiv... | 1.86 $ | 1000 | CONT SPG R HDContact Gold... |
42411000101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BOARD MNT 1A 125VAC/... |
42413000101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BOARD MNT 3A 125VAC/... |
42415000101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BOARD MNT 5A 125VAC/... |
42414000101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BOARD MNT 4A 125VAC/... |
42412500101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BOARD MOUNT 2.5A 125... |
42417000101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BOARD MNT 7A 125VAC/... |
42411500101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BRD MNT 1.5A 125VAC/... |
42412000101 | Littelfuse I... | 0.0 $ | 1000 | FUSE BRD MOUNT 2A 125VAC/... |
42415-1 | TE Connectiv... | 0.04 $ | 1000 | CONN QC RCPT 22-24AWG 0.1... |
70156-4241 | Omron Automa... | 5.54 $ | 1000 | SYSTEM |
D4C-4241 | Omron Automa... | 74.22 $ | 3 | SWITCH SNAP ACT SPDT 100M... |
4241A22UU | APEM Inc. | 5.61 $ | 1000 | SWITCH TOGGLE DPST 6A 125... |
VB-4241 | Omron Automa... | 241.33 $ | 1000 | SWITCH SNAP ACTION SPDT 1... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL