
Allicdata Part #: | 43-10844-ND |
Manufacturer Part#: |
43-10844 |
Price: | $ 12.05 |
Product Category: | Cable Assemblies |
Manufacturer: | Conec |
Short Description: | CONN FEMALE M12X1 ANGLE |
More Detail: | Cable Assembly Circular 04 pos Female, Right Angle... |
DataSheet: | ![]() |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
10 +: | $ 10.95250 |
Series: | 43 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
1st Connector: | M12 Female, Right Angle |
Moisture Sensitivity Level (MSL): | -- |
2nd Connector: | M12 Male |
Number of Positions: | 4 |
Number of Positions Loaded: | All |
Length: | 0.98' (300.00mm) |
Cable Type: | Round |
Color: | Orange |
Shielding: | Unshielded |
Usage: | Industrial Environments - IP67 |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circular Cable Assemblies
Circular cable assemblies are an essential component of almost all electrical systems. They are used for a wide range of applications, from signal transfer in consumer electronics to mounting industrial motors. The 43-10844 standards are a set of guidelines that define the key characteristics of circular cable assemblies, including size, material, and other performance parameters. This article will provide an overview of the application field and working principle of this standard.
Applications
Circular cable assemblies are used in a variety of applications. These include audio/visual systems, automotive electronics, industrial machinery, and computing applications. They are used to transfer signals between multiple devices, provide power to a variety of electronics, and connect components in a system. Because of their versatility, circular cable assemblies can be used in almost any type of system. They are available in various sizes, materials, and configurations, making them ideal for a wide range of applications.
Working Principle
The 43-10844 standard specifies the performance parameters of circular cable assemblies. These parameters include temperature rating, voltage rating, current carrying capacity, environmental resistance, and corrosion resistance.The temperature rating defines the maximum operating temperature of the cable assembly. The voltage rating defines the maximum voltage that can be applied to the assembly. The current carrying capacity defines the maximum current that the cable assembly can carry. The environmental resistance defines the resistance of the cable assembly to environmental conditions such as dust, moisture, and extreme temperatures. The corrosion resistance defines the resistance of the cable assembly to corrosion.
Cable assemblies are constructed according to the 43-10844 standard using a variety of materials. These materials include metal, rubber, fiber, and plastic. The type of material used is determined based on the requirements of the application. Each material has its own unique properties that make it suitable for specific applications. The cable is sealed using a variety of techniques such as soldering, crimping, and lacing. The type of technique used is dependent on the requirements of the application.
The 43-10844 standard also defines the testing procedure for cable assemblies. The tests include electrical, thermal, and mechanical testing. Electrical testing is used to ensure that the cable assemblies can safely handle the electrical currents passed through them. Thermal testing is used to ensure that the cable assemblies can withstand the temperatures encountered during operation. Mechanical testing is used to ensure that the cable assemblies are durable and can withstand the stresses encountered during operation.
The 43-10844 standard also specifies the approvals for cable assemblies. Cable assemblies must meet certain performance requirements in order to receive a UL, CSA, or EIA approval. The approval marks can be found on the body of the cable assembly and indicate that the cable assembly has been tested and approved according to the standards set forth in the 43-10844.
Conclusion
The 43-10844 standards provide a set of guidelines for the design and construction of circular cable assemblies. It defines the key performance parameters of these assemblies and prescribes the required testing and approvals. These standards ensure that the cable assemblies used in any application are safe and reliable. Circular cable assemblies are used in a variety of applications and their use is essential for the safe and efficient operation of modern electronic systems.
The specific data is subject to PDF, and the above content is for reference
CABLE CONNECTORCable Assembly 9.93' (3....

SAC-5P-MS/0 5-647/FR SCO BKCable Assembl...

SENSOR I/O CONNECTORCable Assembly Circu...

CONN FMALE M8 3POS R/A 10M CABLECable As...

CABLE ASSY R/A MALE SNGL 5POS 5MCable As...

CABLE ASSY CORD SET M12Cable Assembly 6...
