
4430.1609 Circuit Protection |
|
Allicdata Part #: | TA45-A121T060C0-ND |
Manufacturer Part#: |
4430.1609 |
Price: | $ 13.45 |
Product Category: | Circuit Protection |
Manufacturer: | Schurter Inc. |
Short Description: | CIR BRKR THRM 6A 240VAC 60VDC |
More Detail: | N/A |
DataSheet: | ![]() |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
20 +: | $ 12.22230 |
Series: | TA45 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 6A |
Voltage Rating - AC: | 240V |
Voltage Rating - DC: | 60V |
Number of Poles: | 2 |
Actuator Type: | Rocker |
Illumination: | Clear |
Illumination Voltage (Nominal): | 220V |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are an essential part of any electrical system, ensuring that a circuit performs its basic function of protecting people and equipment from overloads and short circuits. The 4430.1609 is a specific type of circuit breaker that conforms to certain UL standards and that is certified to provide protection against overloads and short circuits in residential and commercial electrical systems.
The 4430.1609 circuit breaker is a three-pole breaker, meaning it is suitable for connecting three-phase circuits. It has a current rating of 30A and an interrupting rating of 10kA. It is UL 489 listed, meaning that it has passed UL safety testing requirements and is suitable for installation in residential and commercial electrical systems. It is also rated for a voltage of 120/240VAC.
The 4430.1609 circuit breaker has a wide range of uses, particularly in residential and commercial buildings. It can be used as a main breaker, a branch breaker, or a feed-through breaker, depending on the needs of the system. It also has a built-in trip indicator that lets the user know when the breaker has tripped.
In terms of its working principle, the 4430.1609 circuit breaker works by detecting signals from a sensor within the breaker. When an overload or short circuit is detected, the breaker triggers the sensor to trip the breaker and cut the current flow. This prevents damage to the equipment connected to the circuit and prevents the circuit from getting overloaded.
The 4430.1609 circuit breaker is designed for easy installation. It comes with a self-aligning quick connect feature that makes it easy to connect the circuit breaker to a power source. It also has a built-in diagnostic feature that allows the user to test the breaker for problems before it is used.
In order to ensure the safety of the 4430.1609 circuit breaker, it should always be tested before it is used. The circuit breaker should be tested on a regular basis to ensure it continues to provide adequate protection against overloads and short circuits. Additionally, the circuit breaker should be replaced periodically to ensure it continues to function properly and safely.
The 4430.1609 circuit breaker provides reliable protection against overloads and short circuits in residential and commercial electrical systems. It is UL 489 listed, meaning it has passed UL safety testing requirements and is suitable for installation in residential and commercial electrical systems. It is also designed for easy installation and it has a built-in diagnostic feature that allows the user to test the breaker for problems before it is used. Furthermore, the 4430.1609 circuit breaker should be tested on a regular basis and replaced periodically to ensure it continues to provide adequate protection against overloads and short circuits.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
4430.0439 | Schurter Inc... | 0.9 $ | 1000 | GASKET CIRCUIT BRKR 2POLE |
4430.3502 | Schurter Inc... | 13.45 $ | 1000 | CIR BRKR THRM 7A 240VAC 6... |
4430.3008 | Schurter Inc... | 31.54 $ | 1000 | CIR BRKR THRM 20A 240VAC ... |
4430.2039 | Schurter Inc... | 12.4 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4430.2276 | Schurter Inc... | 13.45 $ | 1000 | CIR BRKR THRM 8A 240VAC 6... |
4430.3248 | Schurter Inc... | 19.42 $ | 1000 | CIR BRKR THRM 1.2A 240VAC... |
4430.3324 | Schurter Inc... | 33.24 $ | 1000 | CIR BRKR THRM 15A 240VAC ... |
4430.2051 | Schurter Inc... | 20.32 $ | 101 | CIR BRKR THRM 20A 240VAC ... |
4430.0695 | Schurter Inc... | 2.3 $ | 50 | SCREW COVER CIRCUIT BRKR ... |
4430.0835 | Schurter Inc... | 0.85 $ | 1000 | SCREW COVER CIRCUIT BRKR ... |
4430.1624 | Schurter Inc... | 12.4 $ | 1000 | CIR BRKR THRM 1.2A 240VAC... |
4430F | 3M | 67.4 $ | 1000 | FOAM KIT |
4430.1353 | Schurter Inc... | 14.27 $ | 29 | CIR BRKR THRM 5A 240VAC 6... |
4430.2226 | Schurter Inc... | 37.01 $ | 1000 | CIR BRKR THRM 240VAC 60VD... |
4430.2525 | Schurter Inc... | 17.26 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4430.3709 | Schurter Inc... | 19.42 $ | 1000 | CIR BRKR THRM 15A 240VAC ... |
4430.2307 | Schurter Inc... | 14.27 $ | 15 | CIR BRKR THRM 500MA 240VA... |
4430.3513 | Schurter Inc... | 18.32 $ | 1000 | CIR BRKR THRM 20A 240VAC ... |
4430.0707 | Schurter Inc... | 23.5 $ | 1000 | CIR BRKR THRM 6A 240VAC 6... |
4430.3053 | Schurter Inc... | 26.1 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4430.3361 | Schurter Inc... | 36.85 $ | 1000 | CIR BRKR THRM 240VAC 60VD... |
4430.1248 | Schurter Inc... | 13.45 $ | 1000 | CIR BRKR THRM 2A 240VAC 6... |
4430.2869 | Schurter Inc... | 24.42 $ | 1000 | CIR BRKR THRM 12A 240VAC ... |
4430.0586 | Schurter Inc... | 14.27 $ | 20 | CIR BRKR THRM 5A 240VAC 6... |
4430.1856 | Schurter Inc... | 12.4 $ | 1000 | CIR BRKR THRM 5A 240VAC 6... |
4430.0015 | Schurter Inc... | 13.16 $ | 1000 | CIR BRKR THRM 7A 240VAC 6... |
4430.3661 | Schurter Inc... | 13.45 $ | 1000 | CIR BRKR THRM 8A 240VAC 6... |
4430.3172 | Schurter Inc... | 10.6 $ | 1000 | CIR BRKR THRM 240VAC 60VD... |
4430.1472 | Schurter Inc... | 12.4 $ | 1000 | CIR BRKR THRM 3.8A 240VAC... |
4430.089 | Schurter Inc... | 13.45 $ | 1000 | CIR BRKR THRM 15A 240VAC ... |
4430.3091 | Schurter Inc... | 16.47 $ | 1000 | CIR BRKR THRM 3A 240VAC 6... |
4430.0778 | Schurter Inc... | 13.45 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4430.1961 | Schurter Inc... | 37.02 $ | 1000 | CIR BRKR THRM 16A 240VAC ... |
4430.0428 | Schurter Inc... | 14.27 $ | 1000 | CIR BRKR THRM 4.5A 240VAC... |
4430.0907 | Schurter Inc... | 14.36 $ | 15 | CIR BRKR THRM 240VAC 60VD... |
4430.2872 | Schurter Inc... | 12.4 $ | 1000 | CIR BRKR THRM 6A 240VAC 6... |
4430.3377 | Schurter Inc... | 12.4 $ | 1000 | CIR BRKR THRM 3A 240VAC 6... |
4430.258 | Schurter Inc... | 15.23 $ | 1000 | CIR BRKR THRM 10A 240VAC ... |
4430.2736 | Schurter Inc... | 10.6 $ | 1000 | CIR BRKR THRM 240VAC 60VD... |
4430.2551 | Schurter Inc... | 12.4 $ | 1000 | CIR BRKR THRM 3.5A 240VAC... |
CIRCUIT BREAKER MAG-HYDR LEVER

CIRCUIT BREAKER MAG-HYDR LEVER

CIR BRKR MAG-HYDR 200A 160VDC

CIR BRKR MAG-HYDR

CIRC BRKR THRM

CIR BRKR MAG-HYDR LEVER 10A
