Specifications
Series: *
Part Status: Active
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Fuses are an important safety device. They protect against overdrawing of current and voltage, by acting as an automatic shutoff switch. 5HLE-30E fuses are a type of overcurrent fuse typically used for industrial and commercial applications, specifically in higher voltage ranges. This article will discuss the principles of operation and application field of 5HLE-30E fuses.

Design

5HLE-30E fuses are constructed with two components: a main element and a plastic body. The main element is typically made of nickel-chromium iron (NiCrFe4) wire encased in a ceramic body, often referred to as a ceramic tube. The tube is soldered onto a base. The plastic body is designed to house the main element within a protective case. Generally, 5HLE-30E fuses come in two configurations: class CC and class RK5.

The class CC configuration includes a 10,000 ampere interrupt rating (AIC) with optimized thermal protection, making it suitable for higher voltage applications. The class RK5 has an 11,000 AIC rating. This makes it suitable for lower voltage applications. It is important to note that the voltage ratings of these fuses will vary depending on the manufacturer, so it is important to read the label of the fuse before installation.

Operation

5HLE-30E fuses are designed to protect against an overload or short circuit. When the current exceeds the rated ampere interrupt rating (AIC), the fuse will open and break the electrical circuit. The time it takes for the fuse to open will depend on the amount of current running through the circuit.

When a 5HLE-30E fuse is in use, it is important to note the cut-in and cut-out values. The cut-in value is the amount of current that will cause the fuse to blow once its AIC has been exceeded. The cut-out value is the maximum current that the fuse can safely handle. In general, the cut-in and cut-out values for 5HLE-30E fuses should be as close as reasonably possible in order to ensure optimal protection.

Application Field

5HLE-30E fuses are typically used in industrial and commercial applications requiring higher voltage protection, such as electric motors, pumps, transformers, and HVAC equipment. The higher ratings allow them to handle greater loads, which is important for applications such as transformers and HVAC equipment. They can also be used to provide extra protection to sensitive electronic components, such as those found in consumer electronics.

5HLE-30E fuses are not recommended for use with low voltage applications, such as home wiring. This is due to their higher voltage ratings, which may result in damage to the device or even a fire. It is important to always read the label and consult an electrician to determine the most suitable fuse for a particular application.

Advantages and Disadvantages

The main advantage of 5HLE-30E fuses lies in their ability to provide effective overload protection in higher voltage ranges. They are also designed with optimized thermal protection, making them ideal for higher voltage applications. Additionally, they are designed to work in both class CC and class RK5 configurations, meaning they can be used in a wide variety of applications.

One disadvantage of 5HLE-30E fuses is that they are not suitable for use with lower voltage applications. As mentioned previously, their high voltage ratings may cause damage to the device. Additionally, they can be more expensive than other types of fuses, depending on the manufacturer.

Conclusion

5HLE-30E fuses are a type of fuse designed to provide effective protection against overloads and short circuits in higher voltage applications. They are typically used in industrial and commercial applications, such as pumps, transformers, and HVAC equipment. The main advantage of 5HLE-30E fuses lies in their ability to provide optimized thermal protection. However, it is important to note that they are not suitable for use with lower voltage applications.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "5HLE" Included word is 19
Part Number Manufacturer Price Quantity Description
5HLE-100E Eaton 413.65 $ 1000 5.5KV 100E HLE FUSE
5HLE-10E Eaton 413.65 $ 1000 5.5KV 10E HLE FUSE
5HLE-15E Eaton 413.65 $ 1000 5.5KV 15E HLE FUSE
5HLE-20E Eaton 413.65 $ 1000 5.5KV 20E HLE FUSE
5HLE-25E Eaton 413.65 $ 1000 5.5KV 25E HLE FUSE
5HLE-30E Eaton 413.65 $ 1000 5.5KV 30E HLE FUSE
5HLE-40E Eaton 413.65 $ 1000 5.5KV 40E HLE FUSE
5HLE-50E Eaton 413.65 $ 1000 5.5KV 50E HLE FUSE
5HLE-65E Eaton 413.65 $ 1000 5.5KV 65E HLE FUSE
5HLE-80E Eaton 413.65 $ 1000 5.5KV 80E HLE FUSE
5HLE-125E Eaton 655.5 $ 1000 5.5KV 125E HLE FUSE
5HLE-150E Eaton 655.5 $ 1000 5.5KV 150E HLE FUSE
5HLE-200E Eaton 655.5 $ 1000 5.5KV 200E HLE FUSE
5HLE-250E Eaton 655.5 $ 1000 5.5KV 300E HLE FUSE
5HLE-175E Eaton 680.15 $ 1000 5.5KV HLE MV FUSE, 175E
5HLE-300E Eaton 0.69 $ 1000 5.5KV 300E HLE FUSE
5HLE-350E Eaton 0.69 $ 1000 5.5KV 350E HLE FUSE
5HLE-400E Eaton 0.69 $ 1000 5.5KV 400E HLE FUSE
5HLE-450E Eaton 0.69 $ 1000 FUSE 5.5KV 450E E-RATED
Latest Products
3404.0011.11

FUSE BRD MNT 1.6A 125VAC/VDC SMD

3404.0011.11 Allicdata Electronics
2060.0048.11

FUSE BOARD MNT 3.15A 125VAC/VDC

2060.0048.11 Allicdata Electronics
2060.0043.11

FUSE BOARD MNT 350MA 125VAC/VDC

2060.0043.11 Allicdata Electronics
2060.0013.11

FUSE BRD MNT 2.5A 125VAC/VDC SMD

2060.0013.11 Allicdata Electronics
2060.0011.11

FUSE BRD MNT 1.6A 125VAC/VDC SMD

2060.0011.11 Allicdata Electronics
2040.0715

FUSE BOARD MNT 1A 250VAC RADIAL

2040.0715 Allicdata Electronics