Allicdata Part #: | BEL5955-1000-ND |
Manufacturer Part#: |
9825 0601000 |
Price: | $ 5.54 |
Product Category: | Cables, Wires |
Manufacturer: | Belden Inc. |
Short Description: | 25 PR #28 PP SH PVC |
More Detail: | 50 (25 Pair Twisted) Conductor Multi-Pair Cable Ch... |
DataSheet: | 9825 0601000 Datasheet/PDF |
Quantity: | 1000 |
1 +: | $ 5.04000 |
Jacket (Insulation) Diameter: | 0.429" (10.90mm) |
Shield Coverage: | 100%, 90% |
Shield Material: | Aluminum; Copper, Tinned |
Conductor Insulation: | Polypropylene (PP) |
Jacket (Insulation) Thickness: | 0.0350" (0.889mm) |
Operating Temperature: | -30°C ~ 60°C |
Jacket Color: | Chrome |
Length: | 1000.0' (304.8m) |
Shield Type: | Foil, Braid |
Series: | -- |
Jacket (Insulation) Material: | Poly-Vinyl Chloride (PVC) |
Conductor Material: | Copper, Tinned |
Conductor Strand: | 7/36 |
Wire Gauge: | 28 AWG |
Number of Conductors: | 50 (25 Pair Twisted) |
Cable Type: | Multi-Pair |
Part Status: | Active |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Multiple conductor cables have become a common and accepted part of life, due to their ability to greatly improve the reliability and safety of electrical applications. The 9825 0601000 application field and working principle of multiple conductor cables is perhaps the most critical aspect of their utility. This article will explore the various design aspects of multiple conductor cables, which make them an effective choice for a variety of electrical applications.
Design
Multiple conductor cables are typically composed of a combination of different materials, including plastic, rubber, and metal. The exact material used in each cable will depend upon the specific application, but the commonality is that each wire is carefully insulated with a dielectric material, which can contain an insulating gas or oil mixture, to protect the wire from shocks and high temperatures. This insulation adds to the overall durability of the cable, as it minimizes the effects of moisture, heat, and other environmental factors.
Basic Construction
In order to ensure that multiple conductor cables will perform reliably and safely in many different applications, their construction is usually designed around very specific parameters. For instance, the most common size of a multiple conductor cable is usually rated from 26 to 28 gauge, allowing for a solid rubber insulation which is highly resistant to temperature changes. Additionally, most multiple conductor cables are designed with a temperature range of -55 to 105 degrees Celsius, ensuring a reliable and sustained power delivery.
Wire Gauge and Current Capacity
As mentioned before, the general gauge of multiple conductor cables are usually set to 26 to 28 gauge in order to ensure a reliable and durable connection. Additionally, the current capacity will vary depending on the individual application. Most multiple conductor cables can safely handle between 3 to 5 amperes of current, though some larger cables can support up to 10 amperes of current.
Applications
Multiple conductor cables are commonly used in a wide variety of applications. They can be used to connect two individual devices, such as a controller and an actuator, or multiple circuits in a single device. Multiple conductor cables are also used to connect electrical monitoring devices, such as power meters, enabling real-time monitoring of a system’s performance. Additionally, multiple conductor cables can be used to provide power to industrial machines, computers, and other electrical equipment.
Benefits
Multiple conductor cables are an attractive choice as they offer a number of benefits. First, because of their insulated design, the cables are highly resistant to environmental and external factors. Additionally, these cables are extremely durable, and their design means that they can easily be connected and disconnected without the need for specialized tools.
Conclusion
Multiple conductor cables have become an essential part of many industrial applications. Their ability to handle a variety of different current and voltage levels, as well as their resistance to environmental factors, make them an attractive choice for many electrical applications. The 9825 0601000 application field and working principle of multiple conductor cables is therefore important to understand, as these cables can provide a reliable and safe solution for a variety of electrical applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
40-9825M | Cinch Connec... | 0.64 $ | 117 | CONN D-SUB HOUSING PLUG 2... |
40-9825S | Cinch Connec... | 0.64 $ | 95 | CONN D-SUB HOUSING RECEPT... |
9825 0601000 | Belden Inc. | 5.54 $ | 1000 | 25 PR #28 PP SH PVC50 (25... |
9825DC-6 | 3M | 10.66 $ | 1000 | FILTRETE MICRO ALLERGEN F... |
982594-1 | TE Connectiv... | 11.06 $ | 1000 | PIN,ROUND |
92-7012-9825 | Kester Solde... | 0.0 $ | 1000 | SOLDER FLUX-CORED/296 .02... |
98256 | Desco | 15.3 $ | 10 | ADAPTER AC COMBO TESTER 1... |
9825 060500 | Belden Inc. | 2.77 $ | 1000 | 25 PR #28 PP SH PVC50 (25... |
CABLE 4COND 16AWG YELLOW 250'4 Conductor...
CBL 5E COPPER VIOL FLAME RET PVCConducto...
CABLE 6COND 16AWG BLACK 100'6 Conductor ...
MULTI-PAIR 100COND 28AWG 328.1'100 (50 P...
MULTI-PAIR 8COND 20AWG YEL 1000'8 (4 Pai...
CABLE 2COND 20AWG BLUE 100'2 (1 Pair Twi...