AC120 Circuit Protection |
|
Allicdata Part #: | F10871-ND |
Manufacturer Part#: |
AC120 |
Price: | $ 2.14 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | GDT 120V 5KA |
More Detail: | Gas Discharge Tube 120V 5000A (5kA) 2 Pole User D... |
DataSheet: | ![]() |
Quantity: | 746 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 1.94040 |
5 +: | $ 1.84716 |
10 +: | $ 1.75392 |
50 +: | $ 1.41574 |
100 +: | $ 1.20028 |
250 +: | $ 1.16948 |
500 +: | $ 0.98482 |
1000 +: | $ 0.87711 |
5000 +: | $ 0.76939 |
Series: | AC |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 120V |
Impulse Discharge Current (8/20µs): | 5000A (5kA) |
Tolerance: | -- |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | User Defined |
Package / Case: | Cylinder No Lead |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) play an important role in protecting electrical networks and components from damage due to overvoltage transients. They are commonly used in telecommunications systems, industrial and commercial installations, power grids, and other electrical systems around the world. A Gas Discharge Tube Arrester (GDT) can be composed of two electrodes and a nonlinear gas-filled tube (GDT), or any other equivalent nonlinear dielectric medium.GDTs are used in many different applications, including surge protection, overvoltage protection, power quality improvement, long-distance communication, and many more. GDTs are designed to allow a certain maximum amount of electrical current to pass before they act as a short circuit, preventing further current from passing. GDTs are designed to absorb incoming electrical energy and ensure that significant overvoltage signals are dissipated safely to ground.AC12O GDTs are used in AC circuits, especially in the medium voltage range, where there are frequent voltage lines and peaks. The AC120 GDT has a breakdown voltage of nominal 120 volts. The breakdown voltage is usually somewhere between 110V and 120V. It is designed to protect electrical circuits and equipment from sudden surges in electrical current that can damage or destroy sensitive electronic equipment.The AC120 Gas Discharge Tube Arrester works by utilizing a nonlinear dielectric substance. It works by allowing a certain amount of electrical current to pass, and then acting as a short circuit, preventing further current from passing. When an electrical current breaks through the AC120 GDT\'s dielectric substance, an arc is formed by the electrical charge passing through the tube. This electrical charge is then quickly dissipated to ground.The AC120 GDT\'s working principle is based on the principle of a resistor-capacitor (RC) snubber. The dielectric material acts as a resistor, allowing a certain amount of current to pass, while the “capacitor” is formed by the air between the electrodes in the tube. The air acts as a capacitance, trapping the charge until it is dissipated to ground, protecting the sensitive components of the device.The AC120 GDT also has a response time that is much shorter than the typical discharge time of a standard GDT. This is because of the dielectric’s higher breakdown voltage. The current is switched off much faster, allowing for greater protection against surges and surges for sensitive equipment.The AC120 GDT is designed to be used in applications where a standard GDT may not be suitable. It is especially beneficial for telecommunications systems where there are long electrical lines. The AC120 GDT is also widely used in industrial, commercial, and power applications, helping to protect sensitive and expensive equipment from unexpected electrical surges.In conclusion, the AC120 GDT is an important component when it comes to protecting electrical systems from sudden surges and overvoltage. Its ability to quickly and safely dissipate an electrical arc helps protect sensitive electronic equipment from being damaged or destroyed. Its short response time and higher breakdown voltage allow for greater protection against electrical surges and other damaging voltages. Its wide range of applications make the AC120 GDT a valuable tool for many different electrical systems around the world.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HJ2-AC12V | Panasonic El... | 4.48 $ | 1000 | RELAY GEN PURPOSE DPDT 7A... |
G2R-2A-AC12 | Omron Electr... | 5.04 $ | 1000 | RELAY GEN PURPOSE DPST 5A... |
MKS2P AC12 | Omron Automa... | 12.29 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MM4KP-AC120 | Omron Automa... | 161.0 $ | 1000 | RELAY GEN PURPOSE 4PDT 5A... |
MY4N-GS AC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP 4PDTRelay ... |
MKS3P-V AC120 | Omron Automa... | 15.97 $ | 11 | RELAY GEN PURPOSE 3PDT 10... |
MC-9B-AC120V | Altech Corpo... | 19.57 $ | 1000 | CONTACTOR 3P9A 1 NO/1 NC ... |
S1DX-S4C3M-AC120V | Panasonic In... | 0.0 $ | 1000 | POWER ONE SHOT 4 FORM CTi... |
G2R-1-T AC12 | Omron Automa... | 7.26 $ | 1000 | RELAY GEN PURPOSE SPDT 10... |
LY3-AC12 | Omron Automa... | 10.85 $ | 1000 | RELAY GEN PURPOSE 3PDT 10... |
MC-32A/R-AC120V | Altech Corpo... | 122.05 $ | 1000 | REVERSING CONTACTOR 32A 2... |
S1DXM-M4C10M-AC120V | Panasonic In... | 30.08 $ | 1000 | RELAY TIME DELAY 10MIN 5A... |
HC3-H-AC120V-F | Panasonic El... | 8.34 $ | 1000 | RELAY GEN PURPOSE 3PDT 7A... |
HC4D-HTM-AC12V | Panasonic El... | 0.0 $ | 1000 | RELAY GEN PURP 4PDT 12VAC... |
G2R-1A-AC12 | Omron Electr... | 4.63 $ | 1000 | RELAY GEN PURPOSE SPST 10... |
S1DX-A4C3M-AC120V | Panasonic In... | 0.0 $ | 1000 | LMTD AVLBLTY PLS TRY S1DX... |
MC-50A-AC120V | Altech Corpo... | 79.72 $ | 1000 | CONTACTOR 3P 50A 2 NO/2 N... |
MKS2XTIN-11 AC120 | Omron Automa... | 28.76 $ | 14 | RELAY GEN PURPOSE DPST 5A... |
HE2AN-AC120V | Panasonic El... | 16.74 $ | 20 | RELAY GEN PURPOSE DPST 25... |
MKS3P AC120 | Omron Automa... | 14.36 $ | 8 | RELAY GEN PURPOSE 3PDT 10... |
MJN3C-N-AC120 | Omron Automa... | 20.17 $ | 4 | RELAY GEN PURPOSE 3PDT 10... |
MY4-AC12-EL | Omron Automa... | 10.0 $ | 1000 | RELAY GEN PURPOSE 4PDT 3A... |
H3M-AC120-D | Omron Automa... | 0.0 $ | 1000 | RELAY TIME DELAY 10HR 5A ... |
S1DX-A2C60S-AC120V | Panasonic In... | 0.0 $ | 1000 | LMTD AVLBLTY PLS TRY S1DX... |
S1DX-S4C60S-AC120V | Panasonic In... | 0.0 $ | 1000 | S1DX TIMERTime Delay Rela... |
61F-G1NR AC120/240 | Omron Automa... | 212.84 $ | 1000 | CNTRL LIQ LEV 120/240VAC ... |
PM4HF8R-S-AC120V | Panasonic In... | 48.65 $ | 1000 | ANALOG TIMER DIN48 1-10SE... |
H2C-8-AC120-B | Omron Automa... | 154.17 $ | 999 | RELAY TIME DELAY 6HR 6A 2... |
G2R-2-S AC120(S) | Omron Automa... | 9.67 $ | 397 | RELAY GEN PURPOSE DPDT 5A... |
G2R-2-SNI AC120(S) | Omron Automa... | 13.71 $ | 134 | RELAY GEN PURPOSE DPDT 5A... |
HJ4-L-AC120V | Panasonic El... | 7.32 $ | 1000 | RELAY GEN PURPOSE 4PDT 5A... |
MKS3PN-V-5 AC120 | Omron Automa... | 15.61 $ | 1000 | RELAY GEN PURPOSE 3PDT 10... |
LY1-AC12 | Omron Automa... | 7.39 $ | 1000 | RELAY GEN PURPOSE SPDT 15... |
HP2-AC12V | Panasonic El... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MC-C-22AF-AC120V | Altech Corpo... | 12.13 $ | 1000 | REPLACEMENT COIL 120VAC M... |
61F-G1NH AC120/240 | Omron Automa... | 212.84 $ | 1000 | CNTRL LIQ LEV 120/240VAC ... |
MJN3CF-AC120 | Omron Automa... | 15.31 $ | 19 | RELAY GEN PURPOSE 3PDT 10... |
HE1AN-S-AC12V | Panasonic El... | 19.41 $ | 1000 | RELAY GEN PURPOSE SPST 30... |
HC1E-L-AC120V-F | Panasonic El... | 0.0 $ | 1000 | RELAY GEN PURP SPDT 120VA... |
H2C-8R-AC120-B | Omron Automa... | 0.0 $ | 1000 | RELAY TIME DELAY 6HR 6A 2... |
GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...