APG66-784-1 Circuit Protection |
|
Allicdata Part #: | APG66-784-1-ND |
Manufacturer Part#: |
APG66-784-1 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | APG66-784-1 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | APG |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
APG 66-784-1 circuit breakers are components designed for the purpose of protecting electrical circuits from overload or short-circuiting. The principle of their design is to detect excessive current, and then open the circuit to disconnect the power. Their purpose is to act as a safety device that prevents fires and other damage due to power overloads and short circuits.
APG 66-784-1 circuit breakers are rated for 120/208-Vac applications, and are designed for use in industrial, commercial, and residential electrical systems. The maximum current that can be handled safely by the breaker is 40 amperes. The APG 66-784-1 is a type 1 molded case circuit breaker, as indicated by the 6-digit code affixed to the product.
The working principle of the APG 66-784-1 circuit breaker is relatively simple. The breaker comprises two parts - a spring loaded switch and a thermal-magnetic trip unit. The switch is designed to open the circuit in the event of an excessive current flow (overload). The thermal-magnetic trip unit detects any over-currents and trips the circuit breaker, opening the circuit and preventing further current from flowing.
The APG 66-784-1 circuit breaker is designed to be able to handle over-current conditions as long as they do not exceed the breaker’s rating. When the current exceeds the rating, the thermal-magnetic trip unit triggers and opens the circuit, shutting off the power. An indication light on the circuit breaker will also be lit, indicating that the unit has been tripped.
When the over load or short circuit is removed, the APG 66-784-1 can be reset by moving the reset lever. The device will then resume normal operation. It is important to note, however, that the circuit breaker should not be used to protect against continuous over-currents that exceed the breaker’s rating. If such a situation occurs, it is important to assess the cause of the over-current condition and resolve it before resetting the breaker.
When used correctly, the APG 66-784-1 circuit breaker provides an effective way of protecting electrical circuits from overload or short-circuiting. The device is relatively easy to install and maintain, and is designed to last for many years with proper care. As with any electrical component, it is important to ensure that the circuit breakers are used and installed in accordance with manufacturer\'s guidelines.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
APG666-1-60-303-A-01 | Sensata-Airp... | 0.0 $ | 1000 | CIR BRKR MAG-HYDR 30A 250... |
APG6-1REC2-5426-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-1REC3-4888-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-1REC3-4888-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-1REC4-34728-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-1REC4-34728-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-1REC4-34728-30 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-1REC4-34728-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-21616-12 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-23138-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-23138-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-23503-12 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-23503-8 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-23504-8 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-24431-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-24431-13 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-24431-14 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-24431-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-24431-8 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-24431-9 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG62-6149-16 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-27822-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG6-27822-7 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG66-1561-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG66-21616-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG662-28544-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG66-23503-11 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG66-23503-13 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG66-35053-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG66-35053-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG666-1544-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG666-21563-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG666-23974-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG666-6149-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG666-6821-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG66-784-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG67-1561-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
APG67-31257-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A